Assesing multileaf collimator effect on the build-up region using Monte Carlo method

被引:0
|
作者
Zarza Moreno, M. [1 ,2 ]
Teixeira, N. [3 ,4 ]
Jesus, A. P. [1 ,2 ]
Mora, G. [1 ]
机构
[1] Univ Lisbon, Ctr Fis Nucl, Lisbon, Portugal
[2] Univ Nova Lisboa, Fac Ciencias Tecnol, Lisbon, Portugal
[3] Escola Super Tecnol Saude Lisboa, Lisbon, Portugal
[4] Univ Nova Lisboa, Fac Ciencias Med, Lisbon, Portugal
来源
关键词
surface dose; build-up dose; MLC; IMRT; Monte Carlo;
D O I
10.2478/v10013-008-0014-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Previous Monte Carlo studies have investigated the multileaf collimator ( MLC) contribution to the build-up region for fields in which the MLC leaves were fully blocking the openings defined by the collimation jaws. In the present work, we investigate the same effect but for symmetric and asymmetric MLC defined field sizes ( 2x2, 4x4, 10x10 and 3x7 cm(2)). A Varian 2100C/D accelerator with 120-leaf MLC is accurately modeled for a 6 MV photon beam using the BEAMnrc/EGSnrc code. Our results indicate that particles scattered from accelerator head and MLC are responsible for the increase of about 7% on the surface dose when comparing 2x2 and 10x10 cm(2) fields. We found that the MLC contribution to the total build-up dose is about 2% for the 2x2 cm(2) field and less than 1% for the largest fields.
引用
收藏
页码:163 / 182
页数:20
相关论文
共 50 条
  • [21] Monte Carlo simulation of the dynamic micro-multileaf collimator of a LINAC Elekta Precise using PENELOPE
    Gonzalez, W.
    Lallena, A. M.
    Alfonso, R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (11): : 3417 - 3431
  • [22] Simultaneous effect of collimator size and absorber thickness on the gamma ray build-up factor
    Singh, C
    Sidhu, GS
    Kumar, A
    Singh, PS
    Mudahar, GS
    [J]. INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2004, 42 (07) : 475 - 478
  • [23] Collimator Scatter Factor (Sc) Measurements for IRIS in CyberKnife Using Build-Up Caps
    Lee, S.
    Tien, C.
    Curran, B.
    Jang, S.
    Sternick, E.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [24] Monte Carlo Modeling of Modulated Electron Beams Delivered Through a Photon Multileaf Collimator
    Tynan, P.
    Stathakis, S.
    Esquivel, C.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [25] Novel multileaf collimator designs with tongues and grooves in leaf end and Monte Carlo simulations
    Cui, Weijie
    Tian, Yuan
    Dai, Jianrong
    [J]. MEDICAL DOSIMETRY, 2024, 49 (03) : 254 - 262
  • [26] Implementation of Monte Carlo Dose Calculation for a Multileaf Collimator Equipped Robotic Radiotherapy System
    Li, J. S.
    Fan, J.
    Ma, C-M
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3442 - 3442
  • [27] Leakage evaluation as a function of the tip angle for a non tongue and groove multileaf collimator using Monte Carlo simulation
    Salguero, J
    Sánchez-Doblado, F
    Leal, A
    Linares, R
    Arráns, R
    Leidenberger, S
    Schulze, C
    Szegedi, M
    Tacke, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S150 - S150
  • [28] The effect of electron collimator leaf shape on the build-up dose in narrow electron MLC fields
    Vatanen, T.
    Traneus, E.
    Vaananen, A.
    Lahtinen, T.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (23): : 7211 - 7226
  • [29] Accurate dosimetry in photon build-up region
    Abdel-Rahman, W.
    Devic, S.
    Seuntjens, J.
    Podgorsak, E.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2276 - 2276
  • [30] The Monte Carlo Method as a Tool to Build up Predictive QSPR/QSAR
    Toropov, Andrey A.
    Toropova, Alla P.
    [J]. CURRENT COMPUTER-AIDED DRUG DESIGN, 2020, 16 (03) : 197 - 206