A BODY-WORN GAIT ANALYSIS SYSTEM FOR EVALUATING HEMIPLEGIC GAIT

被引:17
|
作者
GRANAT, MH
MAXWELL, DJ
BOSCH, CJ
FERGUSON, ACB
LEES, KR
BARBENEL, JC
机构
[1] UNIV TWENTE,DIV BIOMED ENGN,7500 AE ENSCHEDE,NETHERLANDS
[2] WESTERN INFIRM & ASSOCIATED HOSP,GARDINER INST,DEPT MED & THERAPEUT,GLASGOW G11 6NT,LANARK,SCOTLAND
关键词
GAIT; HEMIPLEGIA; TEMPORAL PARAMETERS; INSOLES;
D O I
10.1016/1350-4533(95)97321-F
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a system for measuring the temporal parameters of hemiplegic gait. This system uses shoe insoles with sensors, acting as switches, placed under the heel, head of the first metatarsal, head of the fifth metatarsal and the big toe. This system is able to monitor gait for up to 10 min and can be used by the patient over any surface. Parameters for evaluating hemiplegic gait are defined including scuffing during swing and the degree of inversion. during stance.
引用
收藏
页码:390 / 394
页数:5
相关论文
共 50 条
  • [31] Development of an abnormal gait analysis system in gait exercise assist robot "Welwalk" for hemiplegic stroke patients
    Nakashima, Issei
    Imoto, Daisuke
    Hirano, Satoshi
    Mukaino, Masahiko
    Imaida, Masayuki
    Saitoh, Eiichi
    Otaka, Yohei
    2020 8TH IEEE RAS/EMBS INTERNATIONAL CONFERENCE FOR BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2020, : 1030 - 1035
  • [32] Gait analysis and Winters' classification of hemiplegic children
    Nascimbeni, A.
    Gaffuri, A.
    Rigano, M.
    Foglia, C.
    Ghiringhello, S.
    Sabatini, F.
    17TH ESPRM EUROPEAN CONGRESS OF PHYSICAL AND REHABILITATION MEDICINE, 2010, : 81 - +
  • [33] ELECTROMYOGRAPHIC TEMPORAL ANALYSIS OF GAIT - HEMIPLEGIC LOCOMOTION
    PEAT, M
    DUBO, HIC
    WINTER, DA
    QUANBURY, AO
    STEINKE, T
    GRAHAME, R
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1976, 57 (09): : 421 - 425
  • [34] Quantifying postural stability differences in people with Parkinson's disease with and without freezing of gait, using body-worn sensors
    Carlson-Kuhta, P.
    El-Gohary, M.
    Mancini, M.
    Horak, F.
    Huisinga, J.
    MOVEMENT DISORDERS, 2017, 32
  • [35] Is the assessment of 5 meters of gait with body-worn-sensors enough to recognize Parkinsonian gait?
    Amigo, M. E. Mico
    Kingma, I.
    Kunikoshi, A.
    Lummel, R. V.
    Maetzler, W.
    Dieen, J. V.
    MOVEMENT DISORDERS, 2016, 31 : S254 - S254
  • [36] Assessment of hemiplegic gait using the Wisconsin Gait Scale
    Turani, N
    Kemiksizoglu, A
    Karatas, M
    Özker, R
    SCANDINAVIAN JOURNAL OF CARING SCIENCES, 2004, 18 (01) : 103 - 108
  • [37] The effects of gait velocity on the gait characteristics of hemiplegic patients
    You, Young Youl
    Chung, Sin Ho
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (03) : 921 - 924
  • [38] Body-Worn Cameras and Settlements
    Powell, Zachary A.
    JUSTICE EVALUATION JOURNAL, 2024, 7 (02) : 161 - 175
  • [39] A randomized control trial evaluating the effects of police body-worn cameras
    Yokum, David
    Ravishankar, Anita
    Coppock, Alexander
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2019, 116 (21) : 10329 - 10332
  • [40] Body-Worn Sensors in Parkinson's Disease: Evaluating Their Acceptability to Patients
    Fisher, James M.
    Hammerla, Nils Y.
    Rochester, Lynn
    Andras, Peter
    Walker, Richard W.
    TELEMEDICINE AND E-HEALTH, 2016, 22 (01) : 63 - 69