A BODY-WORN GAIT ANALYSIS SYSTEM FOR EVALUATING HEMIPLEGIC GAIT

被引:17
|
作者
GRANAT, MH
MAXWELL, DJ
BOSCH, CJ
FERGUSON, ACB
LEES, KR
BARBENEL, JC
机构
[1] UNIV TWENTE,DIV BIOMED ENGN,7500 AE ENSCHEDE,NETHERLANDS
[2] WESTERN INFIRM & ASSOCIATED HOSP,GARDINER INST,DEPT MED & THERAPEUT,GLASGOW G11 6NT,LANARK,SCOTLAND
关键词
GAIT; HEMIPLEGIA; TEMPORAL PARAMETERS; INSOLES;
D O I
10.1016/1350-4533(95)97321-F
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a system for measuring the temporal parameters of hemiplegic gait. This system uses shoe insoles with sensors, acting as switches, placed under the heel, head of the first metatarsal, head of the fifth metatarsal and the big toe. This system is able to monitor gait for up to 10 min and can be used by the patient over any surface. Parameters for evaluating hemiplegic gait are defined including scuffing during swing and the degree of inversion. during stance.
引用
收藏
页码:390 / 394
页数:5
相关论文
共 50 条
  • [21] Smart Shoe-Based Evaluation of Gait Phase Detection Accuracy Using Body-Worn Accelerometers
    Avvenuti, Marco
    Carbonaro, Nicola
    Cimino, Mario G. C. A.
    Cola, Guglielmo
    Tognetti, Alessandro
    Vaglini, Gigliola
    WIRELESS MOBILE COMMUNICATION AND HEALTHCARE, 2018, 247 : 250 - 257
  • [22] KINEMATIC GAIT ANALYSIS IN HEMIPLEGIC PATIENTS
    OZGIRGIN, N
    BOLUKBASI, N
    BEYAZOVA, M
    ORKUN, S
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1993, 25 (02): : 51 - 55
  • [23] HEMIPLEGIC GAIT - ANALYSIS OF TEMPORAL VARIABLES
    BRANDSTATER, ME
    DEBRUIN, H
    GOWLAND, C
    CLARK, BM
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1983, 64 (12): : 583 - 587
  • [24] GAIT ANALYSIS OF ADULT HEMIPLEGIC PATIENTS
    CRAIK, R
    PEER, M
    COZZENS, B
    LIEBENBERG, R
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1983, 64 (10): : 499 - 499
  • [25] 2.45 GHZ BODY-WORN PLANAR MONOPOLE ANTENNA AND ITS APPLICATION IN BODY-WORN MIMO SYSTEM
    Gao, S.
    Xiao, S.
    Zhu, H.
    Shao, W.
    Wang, B. -Z.
    JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 2011, 25 (5-6) : 661 - 671
  • [26] Specific Distribution of Digital Gait Biomarkers in Parkinson's Disease Using Body-Worn Sensors and Machine Learning
    Cai, Guoen
    Shi, Weikun
    Wang, Yingqing
    Weng, Huidan
    Chen, Lina
    Yu, Jiao
    Chen, Zhonglue
    Lin, Fabin
    Ren, Kang
    Zeng, Yuqi
    Liu, Jun
    Ling, Yun
    Ye, Qinyong
    JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2023, 78 (08): : 1348 - 1354
  • [27] Quantitative gait analysis in children with hemiplegic cerebral palsy equinus gait
    Pringle, DD
    Rodgers, MM
    Albert, MC
    PROCEEDINGS OF THE 1996 FIFTEENTH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1996, : 35 - 38
  • [28] Body-worn sensors capture variability, but not decline, of gait and balance measures in multiple sclerosis over 18 months
    Spain, Rebecca I.
    Mancini, Martina
    Horak, Fay B.
    Bourdette, Dennis
    GAIT & POSTURE, 2014, 39 (03) : 958 - 964
  • [29] 3D Human Gait Reconstruction and Monitoring Using Body-Worn Inertial Sensors and Kinematic Modeling
    Ahmadi, Amin
    Destelle, Francois
    Unzueta, Luis
    Monaghan, David S.
    Linaza, Maria Teresa
    Moran, Kieran
    O'Connor, Noel E.
    IEEE SENSORS JOURNAL, 2016, 16 (24) : 8823 - 8831
  • [30] ASSESSMENT OF GAIT DISABILITY IN HEMIPLEGICS - HEMIPLEGIC GAIT
    WALL, JC
    ASHBURN, A
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1979, 11 (03): : 95 - 103