Bedside Ultrasonography as an Alternative to Computed Tomography Scan for the Measurement of Optic Nerve Sheath Diameter

被引:6
|
作者
Yanamandra, Uday [1 ]
Gupta, Amul [3 ]
Yanamandra, Sushma [2 ]
Das, Subrat Kumar [2 ]
Patyal, Sagarika [4 ]
Nair, Velu [5 ]
机构
[1] Army Hosp Res & Referral, Dept Hematol, New Delhi, India
[2] Army Hosp Res & Referral, New Delhi, India
[3] Mil Hosp, Dept Radiol, Jaipur, Rajasthan, India
[4] Minist Def, New Delhi, India
[5] Gen Med Serv Army, New Delhi, India
关键词
Computed tomography scan; high altitude; intracranial pressure; optic nerve sheath diameter;
D O I
10.4103/jnrp.jnrp_537_17
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Optic nerve sheath diameter (ONSD) as measured by optic nerve sheath ultrasonography (ONSU) is used as a surrogate marker of intracranial pressure (ICP), especially in resource-limited settings. There is a growing interest in the use of ONSU in emergency and high-altitude setups. Notwithstanding multiple studies done on this subject, there is a paucity of data regarding standardization of techniques and comparison of ONSU with computed tomography (CT). Materials and Methods: Thirty-five patients with a diagnosis of high-altitude cerebral edema were enrolled in the study. ONSD was measured in all patients using ONSU, along visual and coronal axis, and CT scan. We repeated ONSU in these patients on days 3, 7, 10, and 15 (day of discharge). Correlation between visual and coronal axis as well as CT scan was analyzed. Results: The correlation of visual to coronal and coronal to visual was equally significant (both correlation coefficients being R-2 = 0.983). Correlation of ONSD by visual axis to CT scan was better than coronal axis (correlation coefficient R-2 = 0.986 vs. 0.96, respectively). Conclusion: In our study, we found a strong correlation between the visual and coronal axes. Thus, either of the two axes can be used for monitoring ICP. However, it has been found that measurements along the coronal axis are challenging, especially in the emergency setup. ONSD measured along visual axis correlated better with CT scan as compared to the coronal axis.
引用
收藏
页码:252 / 255
页数:4
相关论文
共 50 条
  • [21] Bedside Sonographic Measurement of Optic Nerve Sheath Diameter as a Predictor of Increased Intracranial Pressure in Children
    Le, Audrey
    Hoehn, Mary Ellen
    Smith, Mary E.
    Spentzas, Thomas
    Schlappy, David
    Pershad, Jay
    ANNALS OF EMERGENCY MEDICINE, 2009, 53 (06) : 785 - 791
  • [22] Bedside ultrasound measurement of optic nerve sheath diameter in patients with sepsis: a prospective observational study
    Ziyue Yang
    Cuihong Qin
    Shuguang Zhang
    Shaohua Liu
    Tongwen Sun
    Critical Care, 24
  • [23] Ultrasound optic nerve sheath diameter measurement in optic neuritis
    De Bernardo, Maddalena
    Vitiello, Livio
    Kumar, Akshay
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2019, 37 (08): : 1595 - 1596
  • [24] Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults
    Han Chen
    Gui-Sheng Ding
    Yan-Chun Zhao
    Rong-Guo Yu
    Jian-Xin Zhou
    BMC Neurology, 15
  • [25] Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults
    Chen, Han
    Ding, Gui-Sheng
    Zhao, Yan-Chun
    Yu, Rong-Guo
    Zhou, Jian-Xin
    BMC NEUROLOGY, 2015, 15
  • [26] Correlation of optic nerve sheath diameter with directly measured intracranial pressure in Korean adults using bedside ultrasonography
    Jeon, Jin Pyeong
    Lee, Si Un
    Kim, Sung-Eun
    Kang, Suk Hyung
    Yang, Jin Seo
    Choi, Hyuk Jai
    Cho, Yong Jun
    Ban, Seung Pil
    Byoun, Hyoung Soo
    Kim, Young Soo
    PLOS ONE, 2017, 12 (09):
  • [27] Sonographic measurement of the optic nerve sheath diameter at height
    Kunze, Georg
    FLUGMEDIZIN TROPENMEDIZIN REISEMEDIZIN, 2023, 30 (06): : 269 - 270
  • [28] Are ultrasonography measurements of optic nerve sheath diameter an alternative to funduscopy in children with syndromic craniosynostosis? Clinical article
    Driessen, Caroline
    Bannink, Natalja
    Lequin, Maarten
    van Veelen, Marie-Lise C.
    Naus, Nicole C.
    Joosten, Koen F. M.
    Mathijssen, Irene M. J.
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2011, 8 (03) : 329 - 334
  • [29] Optic Nerve Sheath Diameter Ultrasonography in Pediatric Patients with Diabetic Ketoacidosis
    Hansen, Gregory
    Sellers, Elizabeth A. C.
    Beer, Darcy L.
    Vallance, Jeff K.
    Clark, Ian
    CANADIAN JOURNAL OF DIABETES, 2016, 40 (02) : 126 - 130
  • [30] Accuracy of bedside sonographic measurement of optic nerve sheath diameter for intracranial hypertension diagnosis in the emergency department
    Busti, Chiara
    Germini, Federico
    Calabro, Giuseppe
    Corea, Francesco
    Batori, Giuseppe
    Marchetti, Francesco
    Marcosignori, Matteo
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2021, 429