Bedside Ultrasonography as an Alternative to Computed Tomography Scan for the Measurement of Optic Nerve Sheath Diameter

被引:6
|
作者
Yanamandra, Uday [1 ]
Gupta, Amul [3 ]
Yanamandra, Sushma [2 ]
Das, Subrat Kumar [2 ]
Patyal, Sagarika [4 ]
Nair, Velu [5 ]
机构
[1] Army Hosp Res & Referral, Dept Hematol, New Delhi, India
[2] Army Hosp Res & Referral, New Delhi, India
[3] Mil Hosp, Dept Radiol, Jaipur, Rajasthan, India
[4] Minist Def, New Delhi, India
[5] Gen Med Serv Army, New Delhi, India
关键词
Computed tomography scan; high altitude; intracranial pressure; optic nerve sheath diameter;
D O I
10.4103/jnrp.jnrp_537_17
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Optic nerve sheath diameter (ONSD) as measured by optic nerve sheath ultrasonography (ONSU) is used as a surrogate marker of intracranial pressure (ICP), especially in resource-limited settings. There is a growing interest in the use of ONSU in emergency and high-altitude setups. Notwithstanding multiple studies done on this subject, there is a paucity of data regarding standardization of techniques and comparison of ONSU with computed tomography (CT). Materials and Methods: Thirty-five patients with a diagnosis of high-altitude cerebral edema were enrolled in the study. ONSD was measured in all patients using ONSU, along visual and coronal axis, and CT scan. We repeated ONSU in these patients on days 3, 7, 10, and 15 (day of discharge). Correlation between visual and coronal axis as well as CT scan was analyzed. Results: The correlation of visual to coronal and coronal to visual was equally significant (both correlation coefficients being R-2 = 0.983). Correlation of ONSD by visual axis to CT scan was better than coronal axis (correlation coefficient R-2 = 0.986 vs. 0.96, respectively). Conclusion: In our study, we found a strong correlation between the visual and coronal axes. Thus, either of the two axes can be used for monitoring ICP. However, it has been found that measurements along the coronal axis are challenging, especially in the emergency setup. ONSD measured along visual axis correlated better with CT scan as compared to the coronal axis.
引用
收藏
页码:252 / 255
页数:4
相关论文
共 50 条
  • [1] Ultrasonography of the optic nerve sheath diameter
    Simicevic, D. Sodec
    Lovrencic-Huzjan, A.
    Popovic, I. Martinic
    Cvetkovic, V. Vukovic
    Strineka, M.
    Demarin, V.
    JOURNAL OF NEUROLOGY, 2011, 258 : 225 - 225
  • [2] Determination of normal values of optic nerve sheath diameter in newborns with bedside ultrasonography
    Yapicioglu, Hacer
    Aslan, Nagehan
    Sertdemir, Yasar
    Yildizdas, Dincer
    Gulasi, Selvi
    Mert, Kurthan
    EARLY HUMAN DEVELOPMENT, 2020, 145
  • [3] Measurement of optic nerve sheath diameter on computed tomography for the differentiation of transient ischemic attacks
    Kavak, Rasime Pelin
    Kavak, Nezih
    Koca, Senem
    Balci, Nurguel
    Turhan, Berna
    Kaymak, Suemmeya Duran
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2024, 70 (02):
  • [4] Measurement of Optic Nerve Sheath Diameter by Computed Tomography in the Pediatric Population: Normal Values
    Akturk, Yeliz
    Simsir, Begum Demirler
    Hekimo, Baki
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2024, 61 (01) : 38 - 43
  • [5] Optic nerve sheath diameter measurement using bedside ultrasound: Is it accurate?
    Govil, Deepak
    Srinivasan, Shrikanth
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2015, 19 (08) : 443 - 445
  • [6] Bedside measurement of the optic nerve sheath diameter with ultrasound in cerebrovascular disorders
    Yuzbasioglu, Yucel
    Yuzbasioglu, Sema
    Coskun, Selcuk
    Icme, Ferhat
    Oz, Tolga
    Kunt, Refik
    Becel, Sinan
    Akcay, Emine
    Kavakli, Havva Sahin
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2018, 48 (01) : 93 - 99
  • [7] Comparison of ultrasonography and computed tomography for measuring optic nerve sheath diameter for the detection of elevated intracranial pressure
    Kim, Dae Yong
    Kim, Sin Young
    Hong, Dae Young
    Sung, Bo Youn
    Lee, Sung
    Paik, Jin Hui
    Jung, Hyun Min
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2021, 204
  • [8] The evaluation of intracranial pressure evaluation by optic nerve sheath diameter measurement on bedside ultrasonography after ischemic stroke
    Yildiz, Goknur
    Acar, Nurdan
    Cevik, Arif Alper
    Ozdemir, Atilla Ozcan
    Metintas, Selma
    Kaplan, Davut
    Ozakin, Engin
    Yildiz, Can Gokay
    Ayyildiz, Ayse
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2021, 209
  • [9] Interrater reliability of emergency medicine residents in measurement of optic nerve sheath diameter with computed tomography
    Yilmaz, Irem Olcay
    Aksay, Ersin
    Bayram, Basak
    Oray, Nese Colak
    Karabay, Nuri
    TURKISH JOURNAL OF EMERGENCY MEDICINE, 2021, 21 (03): : 117 - 121
  • [10] Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach
    Yanamandra, Uday
    Gupta, Amul
    Bhattachar, Srinivasa A.
    Yanamandra, Sushma
    Das, Subrat K.
    Patyal, Sagarika
    Grewal, Rajan
    Nair, Velu
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2018, 22 (03) : 150 - 153