DISTANCE AND VOLUME MEASUREMENT USING 3-DIMENSIONAL ULTRASONOGRAPHY

被引:0
|
作者
RICCABONA, M [1 ]
NELSON, TR [1 ]
PRETORIUS, DH [1 ]
DAVIDSON, TE [1 ]
机构
[1] UNIV CALIF SAN DIEGO,DEPT RADIOL 0610,LA JOLLA,CA 92093
关键词
3-DIMENSIONAL ULTRASONOGRAPHY; VOLUME; MEASUREMENTS; 2-DIMENSIONAL ULTRASONOGRAPHY;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this study was to assess the accuracy of distance and volume measurements obtained by three-dimensional ultrasonography. A tissue-mimicking phantom was scanned using a prototype three-dimensional sonographic imaging system to verify distance measurements. Measurements were taken from the reconstructed three-dimensional sonographic data and compared to the real distances. Volume measurements were obtained by scanning 30 balloons of various shapes, sized 23 mi to 2400 mi. Each balloon was scanned twice in two orientations; three different masks were accomplished for each volume. Each volume measurement of 180 three-dimensional sonographic measurements was compared to conventional two-dimensional ultrasonographic volume estimates and to the actual, measured balloon size. Distance measurements had a mean error of 0.02 +/- 3.65% (range, -4.27 to 7.18%). Two-dimensional sonographic volume estimates using traditional scanner based methods had a mean error of 13.7 +/- 10.1%. Three-dimensional sonographic volume measurements had a mean error of 2.2 +/- 2.9% for regular and irregular objects over the entire range of volumes. The masking required 10 to 30 min. The field of view varied from 10 to 24 cm with a mean object depth of 9.8 cm. Three-dimensional ultrasonographic methods can provide accurate volume measurements of regular and irregular objects ana offer improved accuracy compared to traditional two-dimensional methods.
引用
收藏
页码:881 / 886
页数:6
相关论文
共 50 条
  • [21] VALIDATION OF THE MEASUREMENT OF HEPATIC VOLUME BY 3-DIMENSIONAL COMPUTED-TOMOGRAPHY
    EVRARD, S
    MOYSES, B
    GHNASSIA, JP
    VIX, M
    MUTTER, D
    METHELIN, G
    MARESCAUX, J
    ANNALES DE CHIRURGIE, 1992, 46 (07): : 601 - 604
  • [22] 3-Dimensional microscopy as a method for volume measurement in cells undergoing apoptosis
    Platonova A.A.
    Koltsova S.V.
    Maksimov G.V.
    Grygorszyk R.
    Orlov S.N.
    Biophysics, 2013, 58 (3) : 389 - 393
  • [23] Sonographic Parameters for Prediction of Miscarriage Role of 3-Dimensional Volume Measurement
    Wie, Jeong Ha
    Choe, Suyearn
    Kim, Sa Jin
    Shin, Jong Chul
    Kwon, Ji Young
    Park, In Yang
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (10) : 1777 - 1784
  • [24] Distance Stereotest Using a 3-Dimensional Monitor for Adult Subjects
    Kim, Jongshin
    Yang, Hee Kyung
    Kim, Youngmin
    Lee, Byoungho
    Hwang, Jeong-Min
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (06) : 1081 - 1086
  • [25] THE PRIMARY APPLICATION OF 3-DIMENSIONAL ULTRASONOGRAPHY IN OBSTETRICS
    KUO, HC
    CHANG, FM
    WU, CH
    YAO, BL
    LIU, CH
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1992, 166 (03) : 880 - 886
  • [26] VOLUVISION - 3-DIMENSIONAL ULTRASONOGRAPHY OF FETAL MALFORMATIONS
    LEE, A
    DEUTINGER, J
    BERNASCHEK, G
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 170 (05) : 1312 - 1314
  • [27] 3-DIMENSIONAL ULTRASONOGRAPHY IN PRENATAL-DIAGNOSIS
    MERZ, E
    BAHLMANN, F
    WEBER, G
    MACCHIELLA, D
    JOURNAL OF PERINATAL MEDICINE, 1995, 23 (03) : 213 - 222
  • [28] VOLUME ESTIMATION OF THE GASTRIC ANTRUM AND THE GALLBLADDER IN PATIENTS WITH NONULCER DYSPEPSIA AND EROSIVE PREPYLORIC CHANGES, USING 3-DIMENSIONAL ULTRASONOGRAPHY
    HAUSKEN, T
    THUNE, N
    MATRE, K
    GILJA, OH
    ODEGAARD, S
    BERSTAD, A
    NEUROGASTROENTEROLOGY AND MOTILITY, 1994, 6 (04): : 263 - 270
  • [29] 3-DIMENSIONAL ANTHROPOMETRIC MEASUREMENT
    GROSS, C
    NEUWIRTH, M
    GRAHAM, J
    PUGH, J
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 361 : 116 - 118
  • [30] Evaluation of the Accuracy of 3-Dimensional Ultrasonography of the Kidney Using an In Vitro Renal Model
    John, Babbin S.
    Rowland, David
    Patel, Uday
    Pilcher, James
    Anson, Ken
    Nassiri, Dariush
    JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (02) : 155 - 162