MEASUREMENT OF FORCE APPLIED DURING MAMMOGRAPHY

被引:40
|
作者
SULLIVAN, DC
BEAM, CA
GOODMAN, SM
WATT, DL
机构
[1] Department of Radiology, Duke University Medical Center, Durham, NC 27710, Trent Dr
关键词
BREAST RADIOGRAPHY; TECHNOLOGY;
D O I
10.1148/radiology.181.2.1924771
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The discomfort that patients experience during mammography is probably related to a variety of factors, one of which might be the amount of compression used. The authors measured the amount of force applied to the breasts during mammography and the resulting breast thickness in 560 women and correlated these measurements with the patient's subjective impression of the examination. The amount of force applied ranged from 49 to 186.2 N (median, 122.5 N). Breast thickness ranged from 10 to 88 mm (median, 46.5 mm). Forty-seven women (8%) rated the examination as painful (ie, mammography was either "very uncomfortable" or "intolerable"). Logistic regression analysis revealed a highly significant relationship between probability of a painful response and ratio of force to thickness (P = .007). Current guidelines suggest that maximum available force be at least 160 N but not more than 200 N. However, because increasing force is associated with increasing likelihood of pain, technologists should be aware that these recommended maximum limits are not intended to be used routinely for all women. In this study, high-quality mammograms were obtained in a majority of women with forces less than the maximum available level.
引用
收藏
页码:355 / 357
页数:3
相关论文
共 50 条
  • [21] Measurement of Muscle Activities for Evaluating Physical Burden and Pain during Mammography Positioning
    Uchiyama, Mieko
    Lee, Yongbum
    Sadakata, Mieko
    Sayama, Mitsuko
    Tsai, Du-Yih
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2012, 228 (01): : 53 - 58
  • [22] Effects of system dynamics and applied force on adhesion measurement in colloidal probe technique
    Lee, Jaeho
    Maharjan, Jayendra
    He, Muyang
    Yeo, Chang-Dong
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2015, 60 : 109 - 116
  • [23] Measurement of osteotomy force during endoscopic sinus surgery
    Joice, Paul
    Ross, Peter D.
    Wang, Dong
    Abel, Eric W.
    White, Paul S.
    ALLERGY & RHINOLOGY, 2012, 3 (02) : E61 - E65
  • [24] Measurement and analysis of grip force during a golf shot
    Komi, E. R.
    Roberts, J. R.
    Rothberg, S. J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2008, 222 (P1) : 23 - 35
  • [25] Measurement of tractive force during acceleration and deceleration periods
    Ohsawa, H
    Furuya, T
    Cao, M
    Kawamura, A
    8TH IEEE INTERNATIONAL WORKSHOP ON ADVANCED MOTION CONTROL, PROCEEDINGS, 2004, : 177 - 181
  • [26] MEASUREMENT OF VELOPHARYNGEAL CLOSURE FORCE DURING VOWEL PRODUCTION
    PIGOTT, RW
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 1995, 32 (03): : 263 - 263
  • [27] Retraction force measurement during transgastric and transvaginal NOTES
    Jamidar, Priya A.
    Mosse, Charles A.
    Cadeddu, Margherita
    Boyd, Michael
    Swain, Paul
    GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB119 - AB119
  • [28] MEASUREMENT OF VELOPHARYNGEAL CLOSURE FORCE DURING VOWEL PRODUCTION
    MOON, JB
    KUEHN, DP
    HUISMAN, JJ
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 1994, 31 (05): : 356 - 363
  • [29] Measurement and recording of traction force during vacuum delivery
    Loghis, C.
    Salamalekis, E.
    PROCEEDINGS OF THE 8TH WORLD CONGRESS OF PERINATAL MEDICINE, 2007, : 567 - 571
  • [30] Measurement of tractive force during acceleration and deceleration periods
    Ohsawa, H. (hohsawa@kawalab.dnj.ynu.ac.jp), IEEE Industrial electronics Society; Institute of Haptics Engineering Society; Keio University; Kawasaki City; et al (Institute of Electrical and Electronics Engineers Inc.):