The paper introduces the first superconducting magnet system for whole body magnetic resonance imaging built in China. The character and composition of the system was described in detail. Warm bore diameter of the magnet system is 1.08m, the length is 2.55m and total weight is 7000kg. The main magnet is composed of six superconducting coils and contributed 0.6T field. The coils are wound with NbTi wire with 1mm diameter and the rated current is 142.6A. Passive shims are used to correct the central field and achieve the uniformity of 2.5ppm in 30cm DSV. The cryostat system is equipped with LHe and LN2 closed-loop refrigerator which have been developed for MRI by CVI.
引用
收藏
页码:631 / 632
页数:2
相关论文
共 50 条
  • [31] MAGNETIC-RESONANCE-IMAGING
    RAGOZZINO, MW
    FIELD, BD
    BEAULIEU, PA
    BRADY, TJ
    DELUCA, SA
    AMERICAN FAMILY PHYSICIAN, 1987, 35 (02) : 107 - 114
  • [32] MAGNETIC-RESONANCE-IMAGING
    FACHE, JS
    CANADIAN FAMILY PHYSICIAN, 1986, 32 : 1087 - 1090
  • [33] MAGNETIC-RESONANCE-IMAGING
    SHORES, A
    VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 1993, 23 (02) : 437 - 459
  • [34] MAGNETIC-RESONANCE-IMAGING
    OPPELT, A
    GRANDKE, T
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1993, 6 (06): : 381 - 395
  • [35] OPTIMAL-DESIGN OF A SELF SHIELDED MAGNETIC-RESONANCE-IMAGING MAGNET
    SOUZA, M
    VIDIGAL, C
    TAQUIN, J
    SAUZADE, M
    JOURNAL DE PHYSIQUE III, 1993, 3 (11): : 2121 - 2132
  • [36] Intraoperative magnetic resonance imaging using a mobile 1.5-tesla magnet
    Sutherland, GR
    Louw, DF
    TECHNIQUES IN NEUROSURGERY, 2002, 7 (04): : 299 - 307
  • [37] FUNCTIONAL MAGNETIC-RESONANCE-IMAGING OF PRIMARY VISUAL PROCESSING USING A 1.0 TESLA SCANNER
    LUNDERVOLD, A
    ERSLAND, L
    GJESDAL, KI
    SMIEVOLL, AI
    TILLUNG, T
    SUNDBERG, H
    HUGDAHL, K
    INTERNATIONAL JOURNAL OF NEUROSCIENCE, 1995, 81 (3-4) : 151 - 168
  • [38] FAT-SUPPRESSED MAGNETIC-RESONANCE-IMAGING AT 1.5 TESLA OF NEOPLASMS OF THE LIVER AND PANCREAS
    HAGSPIEL, KD
    NEIDL, KFW
    HAUSER, M
    DUEWELL, S
    MARINCEK, B
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (03): : 235 - 242
  • [39] PARAMETER OPTIMIZATION AND CALIBRATION OF F-19 MAGNETIC-RESONANCE-IMAGING AT 1.5 TESLA
    GONG, B
    GILL, M
    WASHBURN, DB
    DAVENPORT, WC
    ADAMS, D
    KWOCK, L
    MAGNETIC RESONANCE IMAGING, 1991, 9 (01) : 101 - 106
  • [40] MAGNETIC-RESONANCE-IMAGING OF BRAIN - FUNCTION RATIONALE AND MAGNET APPLICATIONS FOR CLINICAL USE
    BELTRAMELLO, A
    VIOLA, G
    BORSATO, A
    TASSINARI, G
    CAMPARA, D
    CERINI, R
    PREGARZ, M
    PUPPINI, G
    BRICOLO, AG
    RIVISTA DI NEURORADIOLOGIA, 1995, 8 (03): : 345 - 370