FEMORAL-HEAD TECHNOLOGIES TO REDUCE POLYETHYLENE WEAR IN TOTAL HIP-ARTHROPLASTY

被引:0
|
作者
CUCKLER, JM
BEARCROFT, J
ASGIAN, CM
机构
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Efforts to reduce production of polyethylene wear debris are critical to improve the longterm success of total hip arthroplasty: A variety of factors affect the wear between the femoral head and polyethylene acetabular component. Methods of measuring smoothness of femoral heads, the performance of metal alloys and ceramic materials, and the clinical experience comparing the performance of cobalt chrome and ceramic materials are discussed. The rationale for the clinical use of ceramic materials in young, active patients is justified by the current laboratory data from wear testing experiments, but awaits clinical validation.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [21] FEMORAL FRACTURES ASSOCIATED WITH TOTAL HIP-ARTHROPLASTY
    KAVANAGH, BF
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1992, 23 (02) : 249 - 257
  • [22] CLASSIFICATION OF FEMORAL ABNORMALITIES IN TOTAL HIP-ARTHROPLASTY
    DANTONIO, J
    MCCARTHY, JC
    BARGAR, WL
    BORDEN, LS
    CAPPELO, WN
    COLLIS, DK
    STEINBERG, ME
    WEDGE, JH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1993, (296) : 133 - 139
  • [23] FEMORAL WINDOWS IN REVISION TOTAL HIP-ARTHROPLASTY
    KLEIN, AH
    RUBASH, HE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1993, (291) : 164 - 170
  • [24] Effect of femoral component offset on polyethylene wear in total hip arthroplasty
    Sakalkale, DP
    Sharkey, PF
    Eng, K
    Hozack, WJ
    Rothman, RH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) : 125 - 134
  • [25] SIZE OF THE FEMORAL-HEAD AND ACETABULAR REVISION IN TOTAL HIP-REPLACEMENT ARTHROPLASTY
    MORREY, BF
    ILSTRUP, D
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (01): : 50 - 55
  • [26] ACETABULAR CUP WEAR IN TOTAL HIP-ARTHROPLASTY
    RIMNAC, CM
    WILSON, PD
    FUCHS, MD
    WRIGHT, TM
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1988, 19 (03) : 631 - 636
  • [27] WEAR DEBRIS IN CEMENTED TOTAL HIP-ARTHROPLASTY
    HUO, MH
    SALVATI, EA
    BULY, RL
    ORTHOPEDICS, 1991, 14 (03) : 335 - 340
  • [28] Bulk femoral-head autografting in uncemented total hip arthroplasty for acetabular dysplasia
    Shetty, AA
    Sharma, P
    Singh, S
    Tindall, A
    Kumar, SV
    Rand, C
    JOURNAL OF ARTHROPLASTY, 2004, 19 (06): : 706 - 713
  • [29] Comparison of polyethylene wear on the basis of femoral head penetration relative to the acetabulum in total hip arthroplasty.
    Dag, M.
    Benjamin, J. B.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2007, 55 (01) : S133 - S133
  • [30] TOTAL PROSTHESIS ARTHROPLASTY IN NECROSIS OF THE FEMORAL-HEAD
    ELKE, R
    MORSCHER, E
    ORTHOPADE, 1990, 19 (04): : 236 - 241