Effect of femoral component offset on polyethylene wear in total hip arthroplasty

被引:2
|
作者
Sakalkale, DP [1 ]
Sharkey, PF [1 ]
Eng, K [1 ]
Hozack, WJ [1 ]
Rothman, RH [1 ]
机构
[1] Thomas Jefferson Univ, Rothman Inst, Dept Orthopaed, Philadelphia, PA 19107 USA
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Seventeen staged, bilateral total hip arthroplasties performed in 17 patients were reviewed to compare side-to-side polyethylene wear. Implants used on both sides were similar except for implant offset: one hip in each patient was replaced using a femoral component having a standard implant offset, whereas the other side had a lateral offset implant. The mean followup was 5.70 years (range, 2-10.2 years) on the side with a standard femoral implant and 5.67 years (range, 2-9.7 years) on the side with a lateralized femoral component. The only statistically different parameter between the sides was the femoral component offset. All other parameters affecting polyethylene wear, such as period of followup, head size, head type, cup size, cup inclination, medialization of cup, and patient-related factors were similar on both sides, On the side with a standard femoral component, the mean actual prosthetic offset (determined by manufacturer's specifications) was 35.2 mm and the radiologic offset was 31.5 mm, On the side with a lateralized femoral component, the actual prosthetic offset was 42.5 mm and the radiologic offset was 40.1 mm, The difference in offsets between the sides was statistically significant. The mean preoperative offset of the femur was 38.8 mm. Regression analysis revealed that only femoral component offset and cup size correlated significantly with linear wear rate. On the side with a standard femoral component, the linear wear rate was 0.21 mm per year, whereas on the side with a lateralized femoral component, the linear wear rate was 0.10 mm per year. The differences in the linear wear rates were significant. Lateralization of the femoral component in this series more closely restored preoperative hip biomechanics and significantly decreased polyethylene wear.
引用
收藏
页码:125 / 134
页数:10
相关论文
共 50 条
  • [1] The effect of femoral component offset on prosthetic joint stability in total hip arthroplasty.
    Royhal, R
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2000, 48 (01) : 59A - 59A
  • [2] Effect of femoral offset on the gait after total hip arthroplasty
    邬培慧
    [J]. 外科研究与新技术, 2011, 20 (02) : 116 - 116
  • [3] Effect of Femoral Offset on Pain and Function After Total Hip Arthroplasty
    Cassidy, Kevin A.
    Noticewala, Manish S.
    Macaulay, William
    Lee, Jonathan H.
    Geller, Jeffrey A.
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (10): : 1863 - 1869
  • [4] The effect of femoral offset modification on gait after total hip arthroplasty
    Sariali, Elhadi
    Klouche, Shahnaz
    Mouttet, Alexandre
    Pascal-Moussellard, Hugues
    [J]. ACTA ORTHOPAEDICA, 2014, 85 (02) : 123 - 127
  • [5] The effect of femoral offset on polyethylene wear in total hip arthroplasty: a CT-based finite element analysis of 15 patients with simulated gait
    Rudiger, Hannes
    Latypova, Adeliya
    Terrier, Alexandre
    [J]. SWISS MEDICAL WEEKLY, 2018, 148 : 38S - 38S
  • [6] Degree of the Polyethylene Component Wear - a Predictive Factor for the Outcome of Total Hip Arthroplasty
    Radulescu, Radu
    Badila, Adrian
    Manolescu, Robert
    Japie, Ioan
    Badila, Elisabeta
    Bolocan, Alexandra
    Paduraru, Dan Nicolae
    [J]. MATERIALE PLASTICE, 2013, 50 (03) : 212 - 214
  • [7] POLYETHYLENE WEAR IN TOTAL HIP-ARTHROPLASTY
    BANKSTON, AB
    CATES, H
    RITTER, MA
    KEATING, EM
    FARIS, PM
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 7 - 13
  • [8] FEMORAL-HEAD TECHNOLOGIES TO REDUCE POLYETHYLENE WEAR IN TOTAL HIP-ARTHROPLASTY
    CUCKLER, JM
    BEARCROFT, J
    ASGIAN, CM
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 57 - 63
  • [9] Femoral Component Revision of Total Hip Arthroplasty
    Brown, Jonathon M.
    Mistry, Jaydev B.
    Cherian, Jeffrey J.
    Elmallah, Randa K.
    Chughtai, Morad
    Harwin, Steven F.
    Mont, Michael A.
    [J]. ORTHOPEDICS, 2016, 39 (06) : E1129 - E1139
  • [10] Modularity of the Femoral Component in Total Hip Arthroplasty
    Srinivasan, Anand
    Jung, Edward
    Levine, Brett Russell
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2012, 20 (04) : 214 - 222