PERFORMANCE OVER TIME WITH A NUCLEUS OR INERAID COCHLEAR IMPLANT

被引:42
|
作者
TYEMURRAY, N
TYLER, RS
WOODWORTH, GG
GANTZ, BJ
机构
[1] UNIV IOWA,DEPT STAT,IOWA CITY,IA 52242
[2] UNIV IOWA,DIV BIOSTAT,IOWA CITY,IA 52242
来源
EAR AND HEARING | 1992年 / 13卷 / 03期
关键词
D O I
10.1097/00003446-199206000-00010
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
This investigation determined whether the audiological performance of cochlear implant users varied with experience. Thirteen Nucleus and 14 Ineraid subjects were evaluated at 1, 9, and 18 mo after cochlear implant connection. Ten Nucleus and five Ineraid subjects were tested at 30 mo. On average, the ability of the subjects to recognize words and phonemes in an audition-only condition improved during the first 9 mo, as did their ability to recognize spondees in noise. The phoneme scores continued to improve during the next 9 mo. Environmental sound recognition improved gradually; significant improvement from the 1 mo scores was not noted until 18 mo. About half of the subjects who demonstrated poor word recognition at 1 mo showed significantly improved percent word correct scores by 18 mo. The Nucleus and Ineraid subjects did not differ in their patterns of change over time. An information transmission analysis performed on the subjects' consonant confusion matrices showed relatively little change for the nasality and place features during the first 18 mo, and relatively large change for the voice, duration, and frication features. Most improvement in the feature scores occurred during the first 9 mo.
引用
收藏
页码:200 / 209
页数:10
相关论文
共 50 条
  • [31] LONG-TERM MEASURES OF ELECTRODE IMPEDANCE AND AUDITORY-THRESHOLDS FOR THE INERAID COCHLEAR IMPLANT
    DORMAN, MF
    SMITH, LM
    DANKOWSKI, K
    MCCANDLESS, G
    PARKIN, JL
    JOURNAL OF SPEECH AND HEARING RESEARCH, 1992, 35 (05): : 1126 - 1130
  • [32] INERAID (UTAH) MULTICHANNEL COCHLEAR IMPLANTS
    YOUNGBLOOD, J
    ROBINSON, S
    LARYNGOSCOPE, 1988, 98 (01): : 5 - 10
  • [33] The performance of the new BTE speech processor in the nucleus 24 cochlear implant system
    Seligman, P
    Plant, K
    COCHLEAR IMPLANTS, 1996, : 95 - 99
  • [34] Comparison of speech perception performance between the Nucleus 24 and Nucleus 24 Contour cochlear implant systems
    Bacciu, A
    Pasanisi, E
    Vincenti, V
    Guida, M
    Barbot, A
    Berghenti, M
    Forli, F
    Berrettini, S
    Bacciu, S
    ACTA OTO-LARYNGOLOGICA, 2004, 124 (10) : 1155 - 1158
  • [35] PERFORMANCE AS A FUNCTION OF TIME - A STUDY OF 3 COCHLEAR IMPLANT DEVICES
    WESTON, SC
    WALTZMAN, SB
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1995, 104 (04): : 19 - 24
  • [36] DELAYED EXTRUSION OF THE NUCLEUS MULTICHANNEL COCHLEAR IMPLANT
    HOFFMAN, RA
    COHEN, N
    WALTZMAN, S
    SHAPIRO, W
    GOLDOFSKY, E
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1991, 105 (01) : 117 - 119
  • [37] Remote fitting in Nucleus cochlear implant recipients
    Wesarg, Thomas
    Wasowski, Arkadiusz
    Skarzynski, Henryk
    Ramos, Angel
    Falcon Gonzalez, Juan Carlos
    Kyriafinis, George
    Junge, Friederike
    Novakovich, Allan
    Mauch, Herbert
    Laszig, Roland
    ACTA OTO-LARYNGOLOGICA, 2010, 130 (12) : 1379 - 1388
  • [38] Surgical technique for the Nucleus® Contour™ cochlear implant
    Cohen, NL
    Roland, JT
    Fishman, A
    EAR AND HEARING, 2002, 23 (01): : 59S - 66S
  • [39] USING THE TELEPHONE WITH THE CLARK/NUCLEUS COCHLEAR IMPLANT
    MOHMEHESSE, K
    LASZIG, R
    BATTMER, RD
    ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1987, 244 (05): : 313 - 313
  • [40] Audiotactile interaction can change over time in cochlear implant users
    Landry, Simon P.
    Guillemot, Jean-Paul
    Champoux, Francois
    FRONTIERS IN HUMAN NEUROSCIENCE, 2014, 8