PERFORMANCE OVER TIME WITH A NUCLEUS OR INERAID COCHLEAR IMPLANT

被引:42
|
作者
TYEMURRAY, N
TYLER, RS
WOODWORTH, GG
GANTZ, BJ
机构
[1] UNIV IOWA,DEPT STAT,IOWA CITY,IA 52242
[2] UNIV IOWA,DIV BIOSTAT,IOWA CITY,IA 52242
来源
EAR AND HEARING | 1992年 / 13卷 / 03期
关键词
D O I
10.1097/00003446-199206000-00010
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
This investigation determined whether the audiological performance of cochlear implant users varied with experience. Thirteen Nucleus and 14 Ineraid subjects were evaluated at 1, 9, and 18 mo after cochlear implant connection. Ten Nucleus and five Ineraid subjects were tested at 30 mo. On average, the ability of the subjects to recognize words and phonemes in an audition-only condition improved during the first 9 mo, as did their ability to recognize spondees in noise. The phoneme scores continued to improve during the next 9 mo. Environmental sound recognition improved gradually; significant improvement from the 1 mo scores was not noted until 18 mo. About half of the subjects who demonstrated poor word recognition at 1 mo showed significantly improved percent word correct scores by 18 mo. The Nucleus and Ineraid subjects did not differ in their patterns of change over time. An information transmission analysis performed on the subjects' consonant confusion matrices showed relatively little change for the nasality and place features during the first 18 mo, and relatively large change for the voice, duration, and frication features. Most improvement in the feature scores occurred during the first 9 mo.
引用
收藏
页码:200 / 209
页数:10
相关论文
共 50 条
  • [21] PRELINGUALLY DEAFENED CHILDRENS PERFORMANCE WITH THE NUCLEUS MULTICHANNEL COCHLEAR IMPLANT
    MIYAMOTO, RT
    OSBERGER, MJ
    ROBBINS, AM
    MYRES, WA
    KESSLER, K
    AMERICAN JOURNAL OF OTOLOGY, 1993, 14 (05): : 437 - 445
  • [22] PERFORMANCE OF COCHLEAR IMPLANT PATIENTS AS A FUNCTION OF TIME
    SPIVAK, LG
    WALTZMAN, SB
    JOURNAL OF SPEECH AND HEARING RESEARCH, 1990, 33 (03): : 511 - 519
  • [23] PITCH SCALING AND SPEECH UNDERSTANDING BY PATIENTS WHO USE THE INERAID COCHLEAR IMPLANT
    DORMAN, MF
    SMITH, L
    MCCANDLESS, G
    DUNNAVANT, G
    PARKIN, J
    DANKOWSKI, K
    EAR AND HEARING, 1990, 11 (04): : 310 - 315
  • [24] ACOUSTIC CUES FOR CONSONANT IDENTIFICATION BY PATIENTS WHO USE THE INERAID COCHLEAR IMPLANT
    DORMAN, MF
    SOLI, S
    DANKOWSKI, K
    SMITH, LM
    PARKIN, J
    MCCANDLESS, G
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 88 (05): : 2074 - 2079
  • [25] Telemetry changes over time in cochlear implant patients
    El Shennawy, Amira Maged
    Mashaly, Mohamed Magued
    Shabana, Mohamed Ibrahim
    Sheta, Sarah Mohamed
    HEARING BALANCE AND COMMUNICATION, 2015, 13 (01) : 24 - 31
  • [26] PEDIATRIC PERFORMANCE WITH THE NUCLEUS 22-CHANNEL COCHLEAR IMPLANT SYSTEM
    STALLER, SJ
    BEITER, AL
    BRIMACOMBE, JA
    MECKLENBURG, DJ
    ARNDT, P
    AMERICAN JOURNAL OF OTOLOGY, 1991, 12 : 126 - 136
  • [27] Interpolation with the nucleus 22 cochlear implant
    Marsh, RR
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2000, 109 (12): : 84 - 86
  • [28] PERFORMANCE OVER TIME OF CONGENITALLY DEAF AND POSTLINGUALLY DEAFENED CHILDREN USING A MULTICHANNEL COCHLEAR IMPLANT
    FRYAUFBERTSCHY, H
    TYLER, RS
    KELSAY, DM
    GANTZ, BJ
    JOURNAL OF SPEECH AND HEARING RESEARCH, 1992, 35 (04): : 913 - 920
  • [29] Study of telemetry changes over time in children with a cochlear implant
    Asal S.I.
    Sobhy O.A.
    Massad N.D.
    The Egyptian Journal of Otolaryngology, 2018, 34 (3) : 198 - 202
  • [30] Changes in programming over time in postmeningitis cochlear implant users
    Eshraghi, AA
    Telischi, FF
    Hodges, AV
    Odabasi, O
    Balkany, TJ
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2004, 131 (06) : 885 - 889