Adverse reaction to metal debris: metallosis of the resurfaced hip

被引:10
|
作者
Pritchett, James W. [1 ]
机构
[1] Orthopaed Int, Seattle, WA 98104 USA
来源
CURRENT ORTHOPAEDIC PRACTICE | 2012年 / 23卷 / 01期
关键词
chrome-cobalt; hip resurfacing; metallosis;
D O I
10.1097/BCO.0b013e3182356075
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The greatest concern after metal-on-metal hip resurfacing may be the development of metallosis. Metallosis is an adverse tissue reaction to the metal debris generated by the prosthesis and can be seen with implants and joint prostheses. The reasons patients develop metallosis are multifactorial, involving patient, surgical, and implant factors. Contributing factors may include component malposition, edge loading, impingement, third-body particles, and sensitivity to cobalt. The symptoms of metallosis include a feeling of instability, an increase in audible sounds from the hip, and pain that was not present immediately after surgery. The diagnosis is confirmed by aspiration of dark or cloudy fluid from the effusion surrounding the hip joint or by laboratory testing indicating a highly elevated serum cobalt level. Metallosis can develop in a hip with ideal surgical technique and component placement; conversely, some patients with implants placed with less than ideal surgical technique will not develop this complication. Among patients with bilateral hip implants, if metallosis develops it may involve only one hip. Bone loss and tissue necrosis can develop if metallosis is untreated and continues to progress. Surgery is the only effective treatment for progressive metallosis. If there is adequate bone remaining, the acetabular component can be repositioned, keeping the metal-on-metal resurfacing prosthesis. In some patients, it also is possible to change the bearing surface to metal-on-polyethylene. Total hip replacement is an alternative for patients whose resurfacing procedure is complicated by metallosis. Advanced cases may present additional challenges; thus, early surgery is recommended.
引用
收藏
页码:50 / 58
页数:9
相关论文
共 50 条
  • [1] Adverse reaction to metal debris in a painful hemiarthroplasty of the hip
    Palmer, Jonathan Simon
    Dean, Michael William
    Briant-Evans, Toby
    Stranks, Geoff
    [J]. JOURNAL OF SURGICAL CASE REPORTS, 2016, (09):
  • [2] Adverse reaction to metal debris after Birmingham hip resurfacing arthroplasty
    Junnila, Mika
    Seppanen, Matti
    Mokka, Jari
    Virolainen, Petri
    Polonen, Tuukka
    Vahlberg, Tero
    Mattila, Kimmo
    Tuominen, Esa K. J.
    Rantakokko, Juho
    Aarimaa, Ville
    Itala, Ari
    Makela, Keijo T.
    [J]. ACTA ORTHOPAEDICA, 2015, 86 (03) : 345 - 350
  • [3] The use of ultrasound in the diagnosis of adverse reaction to metallic debris following metal on metal hip replacement
    Singisetti, Kiran
    Raju, P. P. J.
    Nargol, Anthony
    [J]. ACTA ORTHOPAEDICA BELGICA, 2019, 85 (01): : 107 - 113
  • [4] Revision of metal-on-metal hip replacements and resurfacings for adverse reaction to metal debris: a systematic review of outcomes
    Matharu, Gulraj S.
    Pynsent, Paul B.
    Dunlop, David J.
    [J]. HIP INTERNATIONAL, 2014, 24 (04) : 311 - 320
  • [5] Metal on metal total hip arthroplasty and a large groin mass: Not always adverse reaction to metallic debris
    Krishnan, Harry
    Magnussen, Alex
    Sharma, Aadhar
    Skinner, John
    [J]. INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2015, 6 : 141 - 145
  • [6] Surface Characterization of Retrieved Metal-on-Metal Total Hip Implants from Patients with Adverse Reaction to Metal Debris
    Burbano, Maria
    Russell, Robert
    Huo, Michael
    Welch, Robert
    Roy, Diana
    Rodrigues, Danieli C.
    [J]. MATERIALS, 2014, 7 (03): : 1866 - 1879
  • [7] A Rare Case of Adverse Reaction to Metal Debris in a Ceramic-on-Ceramic Total Hip Replacement
    Cannella, Adriano
    Greco, Tommaso
    Polichetti, Chiara
    De Martino, Ivan
    Mascio, Antonio
    Maccauro, Giulio
    Perisano, Carlo
    [J]. JOURNAL OF FUNCTIONAL BIOMATERIALS, 2022, 13 (03)
  • [8] Adverse reaction to metal debris in a consecutive series of DUROM™ hip resurfacing: pseudotumour incidence and metal ion concentration
    Hartmann, Albrecht
    Kieback, Jan-Dirk
    Luetzner, Joerg
    Guenther, Klaus-Peter
    Goronzy, Jens
    [J]. HIP INTERNATIONAL, 2017, 27 (04) : 343 - 348
  • [9] Predictors of time to revision and clinical outcomes following revision of metal-on-metal hip replacements for adverse reaction to metal debris
    Matharu, G. S.
    Pynsent, P. B.
    Sumathi, V. P.
    Mittal, S.
    Buckley, C. D.
    Dunlop, D. J.
    Revell, P. A.
    Revell, M. P.
    [J]. BONE & JOINT JOURNAL, 2014, 96B (12): : 1600 - 1609
  • [10] One-Component Revision of Failed Hip Resurfacing from Adverse Reaction to Metal Wear Debris
    Pritchett, James W.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (01): : 219 - 224