One-Component Revision of Failed Hip Resurfacing from Adverse Reaction to Metal Wear Debris

被引:35
|
作者
Pritchett, James W.
机构
来源
JOURNAL OF ARTHROPLASTY | 2014年 / 29卷 / 01期
关键词
total hip arthroplasty; revision; hip resurfacing; wear debris; ARTHROPLASTY; REPLACEMENT; FAILURE; PSEUDOTUMOR; END;
D O I
10.1016/j.arth.2013.04.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study assessed the results of 90 one-component revisions for failed hip resurfacing due to adverse reaction to metal wear debris (76 acetabular, 14 femoral). Patients with a femoral head size 40-45 mm (n = 33) received a two-piece titanium meshed shell with a cross-linlced polyethylene liner and patients with femoral head size 46-54 mm (n = 43) received metal-on-metal components. Patients with femoral head size >45 mm who wished a metal-polyethylene bearing received a dual mobility femoral prosthesis. The mean follow-up was 61 months and the procedure was successful in 97% of the patients. Three failures required re-revision; there was one deep infection. There were no dislocations. One-component revision is a reasonable alternative to revision to total hip arthroplasty. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:219 / 224
页数:6
相关论文
共 50 条
  • [1] Adverse reaction to metal debris following hip resurfacing THE INFLUENCE OF COMPONENT TYPE, ORIENTATION AND VOLUMETRIC WEAR
    Langton, D. J.
    Joyce, T. J.
    Jameson, S. S.
    Lord, J.
    Van Orsouw, M.
    Holland, J. P.
    Nargol, A. V. F.
    De Smet, K. A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (02): : 164 - 171
  • [2] Adverse reaction to metal debris after Birmingham hip resurfacing arthroplasty
    Junnila, Mika
    Seppanen, Matti
    Mokka, Jari
    Virolainen, Petri
    Polonen, Tuukka
    Vahlberg, Tero
    Mattila, Kimmo
    Tuominen, Esa K. J.
    Rantakokko, Juho
    Aarimaa, Ville
    Itala, Ari
    Makela, Keijo T.
    [J]. ACTA ORTHOPAEDICA, 2015, 86 (03) : 345 - 350
  • [3] Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear (vol 93, pg 164, 2011)
    Langton, D. J.
    Joyce, T. J.
    Jameson, S. S.
    Lord, J.
    Van Orsouw, M.
    Holland, J. P.
    Nargol, A. V. F.
    De, Smet K. A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (04): : 566 - 566
  • [4] One-Component Revision in Total Hip Arthroplasty: The Fate of the Retained Component
    Stathopoulos, Ioannis P.
    Lampropoulou-Adamidou, Kalliopi I.
    Vlamis, John A.
    Georgiades, George P.
    Hartofilakidis, George C.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (10): : 2007 - 2012
  • [5] Revision Total Hip Arthroplasty for Aseptically Failed Metal-On-Metal Hip Resurfacing Arthroplasty
    Salmons, Harold I.
    Fruth, Kristin M.
    Lewallen, David G.
    Trousdale, Robert T.
    Berry, Daniel J.
    Abdel, Matthew P.
    [J]. JOURNAL OF ARTHROPLASTY, 2022, 37 (12): : 2399 - 2405
  • [6] Volumetric wear assessment of failed metal-on-metal hip resurfacing prostheses
    Lord, J. K.
    Langton, D. J.
    Nargol, A. V. F.
    Joyce, T. J.
    [J]. WEAR, 2011, 272 (01) : 79 - 87
  • [7] Adverse reaction to metal debris in a consecutive series of DUROM™ hip resurfacing: pseudotumour incidence and metal ion concentration
    Hartmann, Albrecht
    Kieback, Jan-Dirk
    Luetzner, Joerg
    Guenther, Klaus-Peter
    Goronzy, Jens
    [J]. HIP INTERNATIONAL, 2017, 27 (04) : 343 - 348
  • [8] Predictors of time to revision and clinical outcomes following revision of metal-on-metal hip replacements for adverse reaction to metal debris
    Matharu, G. S.
    Pynsent, P. B.
    Sumathi, V. P.
    Mittal, S.
    Buckley, C. D.
    Dunlop, D. J.
    Revell, P. A.
    Revell, M. P.
    [J]. BONE & JOINT JOURNAL, 2014, 96B (12): : 1600 - 1609
  • [9] Revision of metal-on-metal hip replacements and resurfacings for adverse reaction to metal debris: a systematic review of outcomes
    Matharu, Gulraj S.
    Pynsent, Paul B.
    Dunlop, David J.
    [J]. HIP INTERNATIONAL, 2014, 24 (04) : 311 - 320
  • [10] Adverse reaction to metal debris in a painful hemiarthroplasty of the hip
    Palmer, Jonathan Simon
    Dean, Michael William
    Briant-Evans, Toby
    Stranks, Geoff
    [J]. JOURNAL OF SURGICAL CASE REPORTS, 2016, (09):