Absorbed Radiation Dose in Radiosensitive Organs Using 64- and 320-Row Multidetector Computed Tomography: A Comparative Study

被引:3
|
作者
Khan, Atif N. [1 ]
Shuaib, Waqas [2 ]
Nikolic, Boris [3 ]
Khan, Mohammad K. [2 ]
Kang, Jian [2 ]
Khosa, Faisal [1 ,2 ]
机构
[1] Harvard Med Sch, Dept Radiol, Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[2] Emory Univ Hosp, Dept Radiol & Imaging Sci, Atlanta, GA 30308 USA
[3] Albert Einstein Med Ctr, Dept Radiol, Philadelphia, PA 19141 USA
来源
SCIENTIFICA | 2014年 / 2014卷
关键词
D O I
10.1155/2014/305942
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Aim. To determine absorbed radiation dose (ARD) in radiosensitive organs during prospective and full phase dose modulation using ECG-gated MDCTA scanner under 64-and 320-row detector modes. Methods. Female phantom was used to measure organ radiation dose. Five DP-3 radiation detectors were used to measure ARD to lungs, breast, and thyroid using the Aquilion ONE scanner in 64-and 320-row modes using both prospective and dose modulation in full phase acquisition. Five measurements were made using three tube voltages: 100, 120, and 135 kVp at 400mA at heart rate (HR) of 60 and 75 bpm for each protocol. Mean acquisition was recorded in milligrays (mGy). Results. Mean ARD was less for 320-row versus 64-row mode for each imaging protocol. Prospective EKG-gated imaging protocol resulted in a statistically lower ARD using 320-row versus 64-row modes for midbreast (6.728 versus 19.687 mGy, P < 0.001), lung (6.102 versus 21.841 mGy, P < 0.001), and thyroid gland (0.208 versus 0.913 mGy; P < 0.001). Retrospective imaging using 320-versus 64-row modes showed lower ARD for midbreast (10.839 versus 43.169 mGy, P < 0.001), lung (8.848 versus 47.877 mGy, P < 0.001), and thyroid gland (0.057 versus 2.091 mGy; P < 0.001). ARD reduction was observed at lower kVp and heart rate. Conclusions. Dose reduction to radiosensitive organs is achieved using 320-row compared to 64-row modes for both prospective and retrospective gating, whereas 64-row mode is equivalent to the same model 64-row MDCT scanner.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Measurement of Pharyngo-laryngeal Volume During Swallowing Using 320-Row Area Detector Computed Tomography
    Iida, Takatoshi
    Kagaya, Hitoshi
    Inamoto, Yoko
    Shibata, Seiko
    Saitoh, Eiichi
    Kanamori, Daisuke
    Hashimoto, Shuji
    Katada, Kazuhiro
    Tohara, Haruka
    Ueda, Koichiro
    DYSPHAGIA, 2017, 32 (06) : 749 - 758
  • [42] Coronary computed tomography angiography and endocardial leads - Image quality in 320-row CT using iterative reconstruction
    Garmer, Marietta
    Bonsels, Marc
    Metz, Frauke
    Klein-Wiele, Oliver
    Brandts, Bodo
    Groenemeyer, Dietrich
    CLINICAL IMAGING, 2018, 50 : 157 - 163
  • [43] Measurement of Pharyngo-laryngeal Volume During Swallowing Using 320-Row Area Detector Computed Tomography
    Takatoshi Iida
    Hitoshi Kagaya
    Yoko Inamoto
    Seiko Shibata
    Eiichi Saitoh
    Daisuke Kanamori
    Shuji Hashimoto
    Kazuhiro Katada
    Haruka Tohara
    Koichiro Ueda
    Dysphagia, 2017, 32 : 749 - 758
  • [44] Dose evaluation for foetal computed tomography with a 320-row unit in wide-volume mode and an 80-row unit in helical scanning mode: a phantom study
    Matsunaga, Yuta
    Kawaguchi, Ai
    Kobayashi, Masanao
    Suzuki, Shigetaka
    Suzuki, Shoichi
    Chida, Koichi
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (04) : 523 - 530
  • [45] Radiation dose and predictable cancer risk in multidetector-row computed tomography coronary angiography (CTCA)
    Einstein, AJ
    Sanz, J
    Dellegrottaglie, S
    Milite, M
    Henzlova, M
    Rajagopalan, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 114A - 114A
  • [46] Absorbed Radiation Dose in Radiosensitive Organs During Coronary CT Angiography Using 320-MDCT: Effect of Maximum Tube Voltage and Heart Rate Variations
    Nikolic, Boris
    Khosa, Faisal
    Lin, Pei-Jan Paul
    Khan, Atif N.
    Sarwar, Sheryar
    Yam, Chun-Shan
    Court, Laurence E.
    Raptopoulos, Vassilios
    Clouse, Melvin E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : 1347 - 1354
  • [47] Questionable necessity of nitroglycerin for diagnostic coronary artery examination using 320-row multi-detector computed tomography
    Lu, Nan-Han
    Liu, Yi-Shan
    Liu, Ko-In
    Hsu, Shih-Yen
    Huang, Yung-Hui
    Sun, Cheuk-Kwan
    Chen, Tai-Been
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (05) : 989 - 999
  • [48] Diagnostic accuracy of single heart beat 320-row multidetector computed tomography coronary angiography to non-invasively assess in-stent restenosis
    De Graaf, F. R.
    Schuijf, J. D.
    Van Velzen, J. E.
    De Roos, A.
    Reiber, J. H. C.
    Spano, F.
    Jukema, J. W.
    Schalij, M. J.
    Van Der Wall, E. E.
    Bax, J. J.
    EUROPEAN HEART JOURNAL, 2010, 31 : 433 - 433
  • [49] Correlation of ECG-gated 320-row multidetector computed tomography measurement of pulmonary arterial distensibility with hemodynamic factors in chronic thromboembolic pulmonary hypertension
    Kasai, Hajime
    Sugiura, Toshihiko
    Nobuhiro, Tanabe
    Yahaba, Misuzu
    Sakurai, Yoriko
    Shigeta, Ayako
    Kawata, Naoko
    Sakao, Seiichiro
    Kasahara, Yasunori
    Tatsumi, Kouichiro
    EUROPEAN RESPIRATORY JOURNAL, 2013, 42
  • [50] Direct comparison of transthoracic echocardiographic measurement of coronary flow reserve and 320-row multidetector computed tomography coronary angiography for predicting in-stent restenosis
    Kakuta, K.
    Dohi, K.
    Yamanaka, T.
    Kawamura, M.
    Sugimoto, T.
    Nakajima, H.
    Tanigawa, T.
    Yamada, N.
    Nakamura, M.
    Ito, M.
    EUROPEAN HEART JOURNAL, 2011, 32 : 170 - 170