Absorbed Radiation Dose in Radiosensitive Organs Using 64- and 320-Row Multidetector Computed Tomography: A Comparative Study

被引:3
|
作者
Khan, Atif N. [1 ]
Shuaib, Waqas [2 ]
Nikolic, Boris [3 ]
Khan, Mohammad K. [2 ]
Kang, Jian [2 ]
Khosa, Faisal [1 ,2 ]
机构
[1] Harvard Med Sch, Dept Radiol, Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[2] Emory Univ Hosp, Dept Radiol & Imaging Sci, Atlanta, GA 30308 USA
[3] Albert Einstein Med Ctr, Dept Radiol, Philadelphia, PA 19141 USA
来源
SCIENTIFICA | 2014年 / 2014卷
关键词
D O I
10.1155/2014/305942
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Aim. To determine absorbed radiation dose (ARD) in radiosensitive organs during prospective and full phase dose modulation using ECG-gated MDCTA scanner under 64-and 320-row detector modes. Methods. Female phantom was used to measure organ radiation dose. Five DP-3 radiation detectors were used to measure ARD to lungs, breast, and thyroid using the Aquilion ONE scanner in 64-and 320-row modes using both prospective and dose modulation in full phase acquisition. Five measurements were made using three tube voltages: 100, 120, and 135 kVp at 400mA at heart rate (HR) of 60 and 75 bpm for each protocol. Mean acquisition was recorded in milligrays (mGy). Results. Mean ARD was less for 320-row versus 64-row mode for each imaging protocol. Prospective EKG-gated imaging protocol resulted in a statistically lower ARD using 320-row versus 64-row modes for midbreast (6.728 versus 19.687 mGy, P < 0.001), lung (6.102 versus 21.841 mGy, P < 0.001), and thyroid gland (0.208 versus 0.913 mGy; P < 0.001). Retrospective imaging using 320-versus 64-row modes showed lower ARD for midbreast (10.839 versus 43.169 mGy, P < 0.001), lung (8.848 versus 47.877 mGy, P < 0.001), and thyroid gland (0.057 versus 2.091 mGy; P < 0.001). ARD reduction was observed at lower kVp and heart rate. Conclusions. Dose reduction to radiosensitive organs is achieved using 320-row compared to 64-row modes for both prospective and retrospective gating, whereas 64-row mode is equivalent to the same model 64-row MDCT scanner.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Assessment of global left ventricular function and volumes with 320-row multidetector computed tomography: A comparison with 2D-echocardiography
    Fleur R. de Graaf
    Joanne D. Schuijf
    Joëlla E. van Velzen
    Gaetano Nucifora
    Lucia J. Kroft
    Albert de Roos
    Martin J. Schalij
    J. Wouter Jukema
    Ernst E. van der Wall
    Jeroen J. Bax
    Journal of Nuclear Cardiology, 2010, 17 : 225 - 231
  • [32] Detection of plaque rupture using 64-slice multidetector row computed tomography
    Reimann, Ania J.
    Beck, Torsten
    Heuschmid, Martin
    Brodoefel, Harald
    Burgstahler, Christof
    Schroeder, Stephen
    Kopp, Andreas F.
    CANADIAN JOURNAL OF CARDIOLOGY, 2008, 24 (03) : 223 - 224
  • [33] Unenhanced 320-row multidetector computed tomography of the brain in children: comparison of image quality and radiation dose among wide-volume, one-shot volume, and helical scan modes
    Jeon, Sun Kyung
    Choi, Young Hun
    Cheon, Jung-Eun
    Kim, Woo Sun
    Cho, Yeon Jin
    Ha, Ji Young
    Lee, Seung Hyun
    Hyun, Hyejin
    Kim, In-One
    PEDIATRIC RADIOLOGY, 2018, 48 (04) : 594 - 601
  • [34] Unenhanced 320-row multidetector computed tomography of the brain in children: comparison of image quality and radiation dose among wide-volume, one-shot volume, and helical scan modes
    Sun Kyung Jeon
    Young Hun Choi
    Jung-Eun Cheon
    Woo Sun Kim
    Yeon Jin Cho
    Ji Young Ha
    Seung Hyun Lee
    Hyejin Hyun
    In-One Kim
    Pediatric Radiology, 2018, 48 : 594 - 601
  • [35] The dynamics of deglutition during head rotation using dynamic 320-row area detector computed tomography
    Kochi, Kazutaka
    Sei, Hirofumi
    Tanabe, Yuki
    Yasuda, Kazunori
    Kido, Teruhito
    Yamada, Hiroyuki
    Taguchi, Aki
    Hato, Naohito
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2023, 8 (03): : 746 - 753
  • [36] Comparison of Calcium Scoring Between 64-Multidetector Computed Tomography and 320-Multidetector Computed Tomography Using a Cardiac Phantom: Achieving Consistent Image Quality With Dose Optimization
    Tsai, Sung-Yi
    Ding, Xiao-Hua
    Jin, Shih-Chun
    Yi, Dong-Bo
    Chen, Jyh-Cheng
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (01) : 73 - 77
  • [37] 320-Row Multidetector Computed Tomographic Angiogram in the Evaluation of Cerebral Vasospasm After Aneurysmal Subarachnoid Hemorrhage: A Pilot Study
    Hebert, Julien
    Roncarolo, Federico
    Tampieri, Donatella
    Cortes, Maria delPilar
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (04) : 541 - 546
  • [38] Correlation of Coronary Atherosclerosis and Subclinical Plaque Phenotype of Carotid Artery: A 320-Row Multidetector Computed Tomographic Angiography Study
    Zhang, WeiGuo
    Jin, Hang
    Cheng, WeiZhong
    Rao, ShengXiang
    Lu, XiuLiang
    Zeng, Mengsu
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (05) : 701 - 706
  • [39] Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease
    de Graaf, Fleur R.
    Schuijf, Joanne D.
    van Velzen, Joella E.
    Kroft, Lucia J.
    de Roos, Albert
    Reiber, Johannes H. C.
    Boersma, Eric
    Schalij, Martin J.
    Spano, Fabrizio
    Jukema, J. Wouter
    van der Wall, Ernst E.
    Bax, Jeroen J.
    EUROPEAN HEART JOURNAL, 2010, 31 (15) : 1908 - 1915
  • [40] Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience
    Neto, Roberto Sasdelli
    Nomura, Cesar Higa
    Sandoval Macedo, Ana Carolina
    Bianco, Danilo Perussi
    Kay, Fernando Uliana
    Szarf, Gilberto
    da Silva Teles, Gustavo Borges
    Shoji, Hamilton
    Santana Netto, Pedro Vieira
    Duarte Passos, Rodrigo Bastos
    Chate, Rodrigo Caruso
    Ishikawa, Walther Yoshiharu
    Bacellar Costa Lima, Joao Paulo
    Rocha, Marcelo Assis
    Marcos, Vinicius Neves
    Failla, Bruna Bonaventura
    de Gusmao Funari, Marcelo Buarque
    EINSTEIN-SAO PAULO, 2013, 11 (03): : 400 - 404