Reliability and validity of an electronic dynamometer for measuring grip strength COMMENT

被引:0
|
作者
Fitinghoff, Helene [1 ]
机构
[1] Karolinska Inst, Stockholm, Sweden
关键词
D O I
10.12968/ijtr.2011.18.5.265a
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
引用
收藏
页码:265 / 265
页数:1
相关论文
共 50 条
  • [31] REVISED NORMATIVE VALUES FOR GRIP STRENGTH WITH THE JAMAR DYNAMOMETER
    Peters, M. J. H.
    van Nes, S., I
    Vanhoutte, E. K.
    Bakkers, M.
    van Doorn, P. A.
    Merkies, I. S. J.
    Faber, C. G.
    [J]. JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2011, 16 : S107 - S108
  • [32] Which setting of the dynamometer provides maximal grip strength?
    Firrell, JC
    Crain, GM
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (03): : 397 - 401
  • [33] Revised normative values for grip strength with the Jamar dynamometer
    Peters, Martine J. H.
    van Nes, Sonja I.
    Vanhoutte, Els K.
    Bakkers, Mayienne
    van Doorn, Pieter A.
    Merkies, Ingemar S. J.
    Faber, Catharina G.
    [J]. JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2011, 16 (01) : 47 - 50
  • [34] Development of an integrated digital hand grip dynamometer and norm of hand grip strength
    Chang, Ho
    Chen, Chih-Hao
    Huang, Tung-Sun
    Tai, Chun-Yen
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S611 - S617
  • [35] Reliability and Validity of Seated Hip Extensor Strength Measurement by Handheld Dynamometer in Older Adults
    Seko, Toshiaki
    Mori, Mitsuru
    Ohnishi, Hirofumi
    Himuro, Nobuaki
    Takahashi, Yui
    Kumamoto, Tsuneo
    Ito, Toshikazu
    [J]. JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2019, 42 (04) : E39 - E44
  • [36] Reliability and validity of measurements of cervical retraction strength obtained with a hand-held dynamometer
    Tudini, Frank
    Myers, Bradley
    Bohannon, Richard
    [J]. JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2019, 27 (04) : 222 - 228
  • [37] Validity and reliability of an inertial dynamometer using accelerometry
    Jidovtseff, B.
    Crielaard, J. -M.
    Cauchy, S.
    Croisier, J. -L.
    [J]. SCIENCE & SPORTS, 2008, 23 (02) : 94 - 97
  • [38] Reliability and validity of the iSAM 9000 isokinetic dynamometer
    Orri, JC
    Darden, GE
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2006, 77 (01) : A39 - A40
  • [39] RELIABILITY OF THE HAND HELD DYNAMOMETER IN MEASURING MUSCULAR STRENGTH IN PEOPLE WITH INTERSTITIAL LUNG DISEASE
    Dowman, L.
    Mcdonald, C.
    Hill, C.
    Lee, A.
    Barker, K.
    Boote, C.
    Glaspole, I
    Goh, N.
    Southcott, A.
    Burge, A.
    Ndongo, R.
    Martin, A.
    Holland, A.
    [J]. RESPIROLOGY, 2014, 19 : 92 - 92
  • [40] Reliability of the hand held dynamometer in measuring muscle strength in people with interstitial lung disease
    Dowman, Leona
    McDonald, Christine F.
    Hill, Catherine J.
    Lee, Annemarie
    Barker, Kathryn
    Boote, Claire
    Glaspole, Ian
    Goh, Nicole
    Southcott, Annemarie
    Burge, Angela
    Ndongo, Rebecca
    Martin, Alicia
    Holland, Anne E.
    [J]. PHYSIOTHERAPY, 2016, 102 (03) : 249 - 255