Reliability of the hand held dynamometer in measuring muscle strength in people with interstitial lung disease

被引:13
|
作者
Dowman, Leona [1 ,2 ,4 ]
McDonald, Christine F. [3 ,4 ]
Hill, Catherine J. [2 ,4 ]
Lee, Annemarie [4 ,5 ]
Barker, Kathryn [6 ]
Boote, Claire [6 ]
Glaspole, Ian
Goh, Nicole [3 ,4 ,7 ]
Southcott, Annemarie [8 ]
Burge, Angela [5 ]
Ndongo, Rebecca [1 ,4 ]
Martin, Alicia [6 ]
Holland, Anne E. [1 ,4 ,5 ]
机构
[1] La Trobe Univ, Dept Physiotherapy, Alfred Hlth Clin Sch, Alfred Ctr, Prahran, Vic 3181, Australia
[2] Austin Hlth, Dept Physiotherapy, Heidelberg, Vic 3084, Australia
[3] Austin Hlth, Dept Resp & Sleep Med, Heidelberg, Vic 3084, Australia
[4] Inst Breathing & Sleep, Heidelberg, Vic 3084, Australia
[5] Alfred Hlth, Dept Physiotherapy, Prahran, Vic 3181, Australia
[6] Western Hlth, Dept Physiotherapy, Footscray, Vic 3011, Australia
[7] Alfred Hlth, Allergy Immunol & Resp Med Dept, Prahran, Vic 3181, Australia
[8] Western Hlth, Dept Resp & Sleep Disorders Med, Footscray, Vic 3011, Australia
关键词
Interstitial lung diseases; Idiopathic pulmonary fibrosis; Muscle strength; Muscle strength dynamometer; Reliability and validity; EXERCISE CAPACITY; QUADRICEPS STRENGTH; RETEST RELIABILITY; WEAKNESS; TESTS;
D O I
10.1016/j.physio.2015.10.002
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective To evaluate the inter-rater and intra-rater reliability of the hand held dynamometer in measuring muscle strength in people with interstitial lung disease (ILD). Design Test retest reliability of hand-held dynamometry for elbow flexor and knee extensor strength between two independent raters and two testing sessions. Setting Physiotherapy department within a tertiary hospital. Participants Thirty participants with ILD of varying aetiology were included. Twenty participants completed the inter-rater reliability protocol (10 idiopathic pulmonary fibrosis, mean (SD) age 73 (10) years, 11 male) and 21 participants completed the intra-rater reliability protocol (10 idiopathic pulmonary fibrosis, mean age 71 (10) years, 11 male). Main outcome measures Mean muscle strength (kg). Agreement between the two raters and testing sessions was analyzed using Bland Altman plots and reliability was estimated using intraclass correlation coefficients (ICC). Results For elbow flexor strength there was a mean difference between raters of -0.6 kg (limits of agreement (LOA) -5.6 to 4.4 kg) and within raters of -0.3 kg (LOA -2.8 to 2.3 kg). The ICCs were 0.95 and 0.98, respectively. For knee extensor strength there was a mean difference between raters of -1.5 kg (LOA -6.9 to 3.9 kg) and within raters of -0.7 kg (LOA -3.9 to 2.4 kg). The ICCs were 0.95 and 0.97, respectively. Conclusions Hand-held dynamometry is reliable in measuring elbow flexor and knee extensor strength in people with ILD. (C) 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 50 条
  • [1] RELIABILITY OF THE HAND HELD DYNAMOMETER IN MEASURING MUSCULAR STRENGTH IN PEOPLE WITH INTERSTITIAL LUNG DISEASE
    Dowman, L.
    Mcdonald, C.
    Hill, C.
    Lee, A.
    Barker, K.
    Boote, C.
    Glaspole, I
    Goh, N.
    Southcott, A.
    Burge, A.
    Ndongo, R.
    Martin, A.
    Holland, A.
    [J]. RESPIROLOGY, 2014, 19 : 92 - 92
  • [2] Reliability of hand-held dynamometer in measuring gluteus medius isometric muscle strength in healthy population
    Soomro, Rabail Rani
    Karimi, Hossein
    Gillani, Syed Amir
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2022, 38 (05) : 1238 - 1242
  • [3] Measuring muscle strength for people with chronic obstructive pulmonary disease: Retest reliability of hand-held dynamometry
    O'Shea, Simone D.
    Taylor, Nicholas F.
    Paratz, Jennifer D.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (01): : 32 - 36
  • [4] Reliability and Validity of the Hand-Held Dynamometer in Measuring Hip External Rotation Strength
    Quinlevan, Megan
    Boland, Samantha
    Dodge, Erica
    Gribble, Phillip
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 196 - 196
  • [5] Reliability of a new hand-held dynamometer in measuring shoulder range of motion and strength
    Cadogan, Angela
    Laslett, Mark
    Hing, Wayne
    McNair, Peter
    Williams, Maynard
    [J]. MANUAL THERAPY, 2011, 16 (01) : 97 - 101
  • [6] RELIABILITY OF HAND-HELD DYNAMOMETRY IN MEASURING MUSCLE STRENGTH
    BURDETT, RG
    WHITNEY, SL
    [J]. PHYSICAL THERAPY, 1987, 67 (05): : 748 - 748
  • [7] Reliability of muscle strength measures obtained with a hand-held dynamometer in an elderly population
    Buckinx, Fanny
    Croisier, Jean-Louis
    Reginster, Jean-Yves
    Dardenne, Nadia
    Beaudart, Charlotte
    Slomian, Justine
    Leonard, Sylvain
    Bruyere, Olivier
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2017, 37 (03) : 332 - 340
  • [8] EVALUATION OF A HAND-HELD DYNAMOMETER FOR MEASURING MUSCLE STRENGTH UNDER FIELD CONDITIONS
    METCALF, WK
    STUBERG, WA
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1986, 380 : P64 - P64
  • [9] RELIABILITY OF MUSCLE STRENGTH MEASURES OBTAINED WITH A HAND-HELD DYNAMOMETER IN AN ELDERLY POPULATION
    Buckinx, F.
    Croisier, J. L.
    Reginster, J. -Y.
    Dardenne, N.
    Beaudart, C.
    Slomian, J.
    Bruyere, O.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2015, 26 : S161 - S161
  • [10] Reliability and validity of a custom-made instrument including a hand-held dynamometer for measuring trunk muscle strength
    Jubany, Julia
    Busquets, Albert
    Marina, Michel
    Cos, Francesc
    Angulo-Barroso, Rosa
    [J]. JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2015, 28 (02) : 317 - 326