Comparing accuracy of cochlear measurements on magnetic resonance imaging and computed tomography: A step towards radiation-free cochlear implantation

被引:0
|
作者
Anurita Swarup [1 ]
Vinusree Karakkandy [1 ]
Preetam Chappity [1 ]
Suprava Naik [2 ]
Sanjay Kumar Behera [1 ]
Pradipta Kumar Parida [1 ]
Mohnish Grover [3 ]
Gaurav Gupta [4 ]
Prajna Paramita Giri [5 ]
Saurav Sarkar [1 ]
Pradeep Pradhan [1 ]
Dillip Kumar Samal [1 ]
Aswathi Kallyadan Veetil [1 ]
Asutosh Adhikari [1 ]
Saurav Nayak [6 ]
机构
[1] Department of ENT and HNS, All India Institute of Medical Sciences (AIIMS)
[2] Department of Radiodiagnosis, All India Institute of Medical Sciences (AIIMS)
[3] Department of ENT, Sawai Man Singh Medical College
[4] Department of ENT, Sardar Patel Medical College
[5] Department of Community and Family Medicine, All India Institute of Medical Sciences (AIIMS)
[6] Department of Biochemistry, All India Institute of Medical Sciences (AIIMS)
关键词
D O I
暂无
中图分类号
R764.9 [耳部外科手术];
学科分类号
100213 ;
摘要
Objective: Computed Tomography(CT) and Magnetic Resonance Imaging(MRI) are commonly employed in pre-operative evaluation for cochlear implant surgery. However, with a decrease in the age of implantation, even minor radiation exposure can cause detrimental effects on children over their lifetime.The current study compares different cochlear measurements from CT and MRI scans and evaluates the feasibility of using only an MRI scan for radiological evaluation before cochlear implantation.Methods: A longitudinal observational study was conducted on 94 ears/47 children, employing CT and MRI scans. The CT and MRI scan measurements include, A value, B value, Cochlear duct length(CDL), twoturn cochlear length, alpha and beta angles to look for cochlear orientation. Cochlear nerve diameter was measured using MRI. The values were compared.Results: The mean difference between measurements from CT and MRI scans for A value, B value, CDL,and two-turn cochlear length values was 0.567 ± 0.413 mm, 0.406 ± 0.368 mm, 2.365 ± 1.675 mm, and2.063 ± 1.477 mm respectively without any significant difference. The alpha and beta angle measures were comparable, with no statistically significant difference.Conclusion: The study suggests that MRI scans can be the only radiological investigation needed with no radiation risk and reduces the cost of cochlear implant program in the paediatric population. There is no significant difference between the measurements obtained from CT and MRI scans. However, observed discrepancies in cochlear measurements across different populations require regionally or race-specific standardized values to ensure accurate diagnosis and precision in cochlear implant surgery. This aspect must be addressed to ensure positive outcomes for patients.
引用
收藏
页码:208 / 213
页数:6
相关论文
共 50 条
  • [41] Computed tomography versus magnetic resonance imaging in paediatric cochlear implant assessment: a pilot study and our experience at Great Ormond Street Hospital
    Kanona, H.
    Stephenson, K.
    D'Arco, F.
    Rajput, K.
    Cochrane, L.
    Jephson, C.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2018, 132 (06): : 529 - 533
  • [42] Accuracy of radiography, computed tomography and magnetic resonance imaging in diagnosing foreign bodies in the foot
    Pattamapaspong, N.
    Srisuwan, T.
    Sivasomboon, C.
    Nasuto, M.
    Suwannahoy, P.
    Settakorn, J.
    Kraisarin, J.
    Guglielmi, G.
    RADIOLOGIA MEDICA, 2013, 118 (02): : 303 - 310
  • [43] INDICATIONS FOR AND ACCURACY OF MAGNETIC-RESONANCE-IMAGING AND COMPUTED-TOMOGRAPHY IN ORBITAL DISEASE
    AINSWORTH, JR
    HADLEY, DM
    MACPHERSON, P
    MCFADZEAN, R
    LAWRENCE, A
    TEASDALE, GM
    SCOTTISH MEDICAL JOURNAL, 1992, 37 (01) : 11 - 17
  • [44] Diagnostic Accuracy of Magnetic Resonance Imaging and Computed Tomography Scan in Young Athletes With Spondylolysis
    West, Amy M.
    d'Hemecourt, Pierre A.
    Bono, Olivia J.
    Micheli, Lyle J.
    Sugimoto, Dai
    CLINICAL PEDIATRICS, 2019, 58 (06) : 671 - 676
  • [45] Scalar localization of the electrode array after cochlear implantation: A cadaveric validation study comparing 64-slice multidetector computed tomography with microcomputed tomography
    Lane, John I.
    Driscoll, Colin L. W.
    Witte, Robert J.
    Primak, Andrew
    Lindell, Edward P.
    OTOLOGY & NEUROTOLOGY, 2007, 28 (02) : 191 - 194
  • [46] Magnetic Resonance Imaging May Be a Valuable Radiation-Free Technique for Lung Pathologies in Patients with Primary Immunodeficiency
    Arslan, Sevket
    Poyraz, Necdet
    Ucar, Ramazan
    Yesildag, Mihrican
    Yesildag, Ahmet
    Caliskaner, Ahmet Zafer
    JOURNAL OF CLINICAL IMMUNOLOGY, 2016, 36 (01) : 66 - 72
  • [47] Magnetic Resonance Imaging May Be a Valuable Radiation-Free Technique for Lung Pathologies in Patients with Primary Immunodeficiency
    Sevket Arslan
    Necdet Poyraz
    Ramazan Ucar
    Mihrican Yesildag
    Ahmet Yesildag
    Ahmet Zafer Caliskaner
    Journal of Clinical Immunology, 2016, 36 : 66 - 72
  • [48] Correlation of optic nerve sheath diameter measurements by computed tomography and magnetic resonance imaging
    Kalantari, Hossein
    Jaiswal, Rajnish
    Bruck, Isaac
    Matari, Hussein
    Ghobadi, Farzaneh
    Weedon, Jeremy
    Hassen, Getaw Worku
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (11): : 1595 - 1597
  • [49] Magnetic resonance and computed tomography imaging fusion for live guidance of percutaneous pulmonary valve implantation
    Goreczny, Sebastian
    Dryzek, Pawel
    Moszura, Tomasz
    Lukaszewski, Maciej
    Podgorski, Michal
    Nordmeyer, Sarah
    Kuehne, Titus
    Berger, Felix
    Schubert, Stephan
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2018, 14 (04): : 413 - 421
  • [50] Diagnostic accuracy of computed tomography pulmonary angiography and magnetic resonance imaging for an acute pulmonary embolism
    Sodhi, K. S.
    Saxena, A. K.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2012, 10 (05) : 961 - 961