Measurement of left ventricular volumes and ejection fraction by quantitative gated SPET, contrast ventriculography and magnetic resonance imaging: a meta-analysis

被引:0
|
作者
Chisato Kondo
Kenji Fukushima
Kiyoko Kusakabe
机构
[1] Tokyo Women's Medical University School of Medicine,Division of Nuclear Medicine, Department of Radiology
关键词
Quantitative gated SPET; Ventriculography; Magnetic resonance imaging; Ejection fraction; Meta-analysis;
D O I
暂无
中图分类号
学科分类号
摘要
All previous validation studies of quantitative gated single-photon emission tomography (QGS) have examined relatively few patients, and the accuracy of QGS thus remains uncertain. We performed a meta-analysis of data from 301 participants in ten studies that compared QGS using technetium-99m-labelled tracers with contrast left ventriculography (LVG), and from 112 participants in six studies that compared QGS with magnetic resonance imaging (MRI). Linear regression and Bland-Altman analyses were used to evaluate pooled data from individuals across the studies. . The correlation between QGS and LVG for end-diastolic volume (EDV) (r=0.81, SEE=27 ml), end-systolic volume (ESV) (r=0.83, SEE=18 ml) and ejection fraction (EF) (r=0.79, SEE=8.3%) was good, as was that between QGS and MRI for EDV (r=0.87, SEE=34 ml), ESV (r=0.89, SEE=27 ml) and EF (r=0.88, SEE=7.2%). However, Bland-Altman plots indicated that LVG minus QGS differences for EDV generated a systematic and random error of 32±58 ml (mean±2SD), and that MRI minus QGS generated an error of 13±73 ml. In the subgroup of patients in whom ECG gating was set at eight intervals, QGS significantly underestimated EF by 7.6%±17.4% (mean±2SD) compared with LVG and by 6.3%±14.6% compared with MRI; no such underestimation was observed in the subgroup in whom ECG gating was set at 16 intervals. We conclude that in patients with ECG gating set at eight intervals, QGS systematically underestimates LV volumes and EF compared with both LVG and MRI. Since QGS also shows considerable variations around the systematic deviations, there remains uncertainty over whether an individual value determined with QGS approximates the true LV volumes and EF.
引用
收藏
页码:851 / 858
页数:7
相关论文
共 50 条
  • [41] COMPARISON OF GATED SPECT WITH CARDIAC CT FOR THE ASSESSMENT OF LEFT VENTRICULAR VOLUMES AND LEFT VENTRICULAR EJECTION FRACTION
    Subramanian, L.
    Warrington, J. C.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2012, 181 : S455 - S456
  • [42] COMPARATIVE ANALYSIS OF LEFT VENTRICULAR EJECTION FRACTION ASSESSMENT: VISUAL ESTIMATION VIA ECHOCARDIOGRAPHY VERSUS QUANTITATIVE MEASUREMENT THROUGH CARDIOVASCULAR MAGNETIC RESONANCE IMAGING
    Tamiz, Muhammad Ahmed
    Khawaja, Rizwan Ali
    Sultan, Fateh Ali Tipoo
    Rahim, Anum
    PAKISTAN HEART JOURNAL, 2024, 57 (02): : 117 - 121
  • [43] THE ACCURACY OF RADIONUCLIDE VENTRICULOGRAPHY IN THE ANALYSIS OF LEFT-VENTRICULAR EJECTION FRACTION
    SLUTSKY, RA
    BHARGAVA, V
    HIGGINS, CB
    COMPUTERS AND BIOMEDICAL RESEARCH, 1983, 16 (03): : 234 - 246
  • [44] The assessment of left ventricular volumes and ejection fraction with magnetic resonance imaging and echocardiography with automatic border detection: A comparative study
    Kuperstein, R
    Nachtomy, E
    Akselrod, S
    Vered, Z
    JOURNAL OF CARDIOVASCULAR DIAGNOSIS AND PROCEDURES, 1998, 15 (04): : 269 - 275
  • [45] Assessment of left ventricular ejection fraction measured by quantitative gated SPECT
    Abe, K
    Hirakawa, K
    Yonenaga, T
    Kobayashi, S
    Nishimura, M
    Ayabe, Z
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (02): : 223 - 230
  • [46] Validation of an evaluation routine for left ventricular volumes, ejection fraction and wall motion from gated cardiac FDG PET: a comparison with cardiac magnetic resonance imaging
    Wolfgang M. Schaefer
    Claudia S. A. Lipke
    Bernd Nowak
    Hans Juergen Kaiser
    Arno Buecker
    Gabriele A. Krombach
    Udalrich Buell
    Harald P. Kühl
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 545 - 553
  • [47] Correlation of left ventricular ejection fraction by gated SPECT Tc99m sestamibi imaging with contrast ventriculography at subsequent cardiac catheterization.
    Piriz, JM
    Kiernan, FJ
    Eldin, A
    Feroze, H
    McMahon, M
    Russell, A
    Travin, MI
    McKay, RG
    Waters, D
    Heller, GV
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 409 - 409
  • [48] Determination of left ventricular volumes and ejection fraction: comparison of quantitative and model based analysis of ECG-gated SPECT and PET
    Khorsand, A.
    Graf, S.
    Gyongyosi, M.
    Zamini, S.
    Sochor, H.
    Maurer, G.
    Porenta, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S243 - S244
  • [49] Validation of an evaluation routine for left ventricular volumes, ejection fraction and wall motion from gated cardiac FDG PET:: a comparison with cardiac magnetic resonance imaging
    Schaefer, WM
    Lipke, CSA
    Nowak, B
    Kaiser, HJ
    Buecker, A
    Krombach, GA
    Buell, U
    Kühl, HP
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) : 545 - 553
  • [50] Visual estimation versus quantitative assessment of left ventricular ejection fraction: A comparison by cardiovascular magnetic resonance imaging
    Sievers, B
    Kirchberg, S
    Franken, U
    Puthenveettil, BJ
    Bakan, A
    Trappe, HJ
    AMERICAN HEART JOURNAL, 2005, 150 (04) : 737 - 742