Measurement of left ventricular volumes and ejection fraction by quantitative gated SPET, contrast ventriculography and magnetic resonance imaging: a meta-analysis

被引:0
|
作者
Chisato Kondo
Kenji Fukushima
Kiyoko Kusakabe
机构
[1] Tokyo Women's Medical University School of Medicine,Division of Nuclear Medicine, Department of Radiology
关键词
Quantitative gated SPET; Ventriculography; Magnetic resonance imaging; Ejection fraction; Meta-analysis;
D O I
暂无
中图分类号
学科分类号
摘要
All previous validation studies of quantitative gated single-photon emission tomography (QGS) have examined relatively few patients, and the accuracy of QGS thus remains uncertain. We performed a meta-analysis of data from 301 participants in ten studies that compared QGS using technetium-99m-labelled tracers with contrast left ventriculography (LVG), and from 112 participants in six studies that compared QGS with magnetic resonance imaging (MRI). Linear regression and Bland-Altman analyses were used to evaluate pooled data from individuals across the studies. . The correlation between QGS and LVG for end-diastolic volume (EDV) (r=0.81, SEE=27 ml), end-systolic volume (ESV) (r=0.83, SEE=18 ml) and ejection fraction (EF) (r=0.79, SEE=8.3%) was good, as was that between QGS and MRI for EDV (r=0.87, SEE=34 ml), ESV (r=0.89, SEE=27 ml) and EF (r=0.88, SEE=7.2%). However, Bland-Altman plots indicated that LVG minus QGS differences for EDV generated a systematic and random error of 32±58 ml (mean±2SD), and that MRI minus QGS generated an error of 13±73 ml. In the subgroup of patients in whom ECG gating was set at eight intervals, QGS significantly underestimated EF by 7.6%±17.4% (mean±2SD) compared with LVG and by 6.3%±14.6% compared with MRI; no such underestimation was observed in the subgroup in whom ECG gating was set at 16 intervals. We conclude that in patients with ECG gating set at eight intervals, QGS systematically underestimates LV volumes and EF compared with both LVG and MRI. Since QGS also shows considerable variations around the systematic deviations, there remains uncertainty over whether an individual value determined with QGS approximates the true LV volumes and EF.
引用
收藏
页码:851 / 858
页数:7
相关论文
共 50 条
  • [31] Comparison of left ventricular volumes and ejection fraction by monoplane cineventriculography, unenhanced echocardiography and cardiac magnetic resonance imaging
    Li, Chunjian
    Lossnitzer, Dirk
    Katus, Hugo A.
    Buss, Sebastian J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (05): : 1003 - 1010
  • [32] Comparison of left ventricular volumes and ejection fraction by monoplane cineventriculography, unenhanced echocardiography and cardiac magnetic resonance imaging
    Chunjian Li
    Dirk Lossnitzer
    Hugo A. Katus
    Sebastian J. Buss
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1003 - 1010
  • [33] Administration of an intravenous perfluorocarbon contrast agent improves echocardiographic determination of left ventricular volumes and ejection fraction: Comparison with cine magnetic resonance imaging
    Hundley, WG
    Kizilbash, AM
    Afridi, I
    Franco, F
    Peshock, RM
    Grayburn, PA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) : 1426 - 1432
  • [34] Assessment of left ventricular volumes and ejection fraction by live 3-D-contrast enhanced echocardiography comparison with cine magnetic resonance imaging
    Pasquet, AA
    Gerber, B
    Vancrayenest, D
    D'Hondt, AM
    Vanoverschelde, JL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 343A - 344A
  • [35] Assessment of left ventricular ejection fraction measured by quantitative gated SPECTCorrelation with left ventriculography and first-pass radionuclide angiography
    Koichiro Abe
    Koichi Hirakawa
    Takenori Yonenaga
    Satoshi Kobayashi
    Masao Nishimura
    Zenji Ayabe
    The International Journal of Cardiovascular Imaging, 2006, 22 : 223 - 230
  • [36] Left Ventricular Ejection Fraction and Volumes: It Depends on the Imaging Method
    Wood, Peter W.
    Choy, Jonathan B.
    Nanda, Navin C.
    Becher, Harald
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (01): : 87 - 100
  • [37] Quantitation of right ventricular volumes and ejection fraction by three-dimensional echocardiography in patients: Comparison with magnetic resonance imaging and radionuclide ventriculography
    Nesser, H. Joachim
    Tkalec, Wolfgang
    Patel, Ayan R.
    Masani, Navroz D.
    Niel, J.
    Markt, Bernhard
    Pandian, Natesa G.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (08): : 666 - 680
  • [38] Contrast echocardiography and magnetic resonance imaging to predict recovery of left ventricular ejection fraction after coronary intervention
    Biagini, E
    van Geuns, RJ
    Baks, T
    Rizzello, V
    Galema, TW
    de Feyter, PJ
    Ten Cate, FJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 38A - 39A
  • [39] Attenuation corrected gated SPECT for the assessment of left ventricular ejection fraction and volumes
    Riemer H. J. A. Slart
    René A. Tio
    Clark J. Zeebregts
    Antoon T. M. Willemsen
    Rudi A. J. O. Dierckx
    Johan De Sutter
    Annals of Nuclear Medicine, 2008, 22 : 171 - 176
  • [40] Attenuation corrected gated SPECT for the assessment of left ventricular ejection fraction and volumes
    Slart, Riemer H. J. A.
    Tio, Rene A.
    Zeebregts, Clark J.
    Willemsen, Antoon T. M.
    Dierckx, Rudi A. J. O.
    De Sutter, Johan
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (03) : 171 - 176