Measurement of left ventricular volumes and ejection fraction by quantitative gated SPET, contrast ventriculography and magnetic resonance imaging: a meta-analysis

被引:0
|
作者
Chisato Kondo
Kenji Fukushima
Kiyoko Kusakabe
机构
[1] Tokyo Women's Medical University School of Medicine,Division of Nuclear Medicine, Department of Radiology
关键词
Quantitative gated SPET; Ventriculography; Magnetic resonance imaging; Ejection fraction; Meta-analysis;
D O I
暂无
中图分类号
学科分类号
摘要
All previous validation studies of quantitative gated single-photon emission tomography (QGS) have examined relatively few patients, and the accuracy of QGS thus remains uncertain. We performed a meta-analysis of data from 301 participants in ten studies that compared QGS using technetium-99m-labelled tracers with contrast left ventriculography (LVG), and from 112 participants in six studies that compared QGS with magnetic resonance imaging (MRI). Linear regression and Bland-Altman analyses were used to evaluate pooled data from individuals across the studies. . The correlation between QGS and LVG for end-diastolic volume (EDV) (r=0.81, SEE=27 ml), end-systolic volume (ESV) (r=0.83, SEE=18 ml) and ejection fraction (EF) (r=0.79, SEE=8.3%) was good, as was that between QGS and MRI for EDV (r=0.87, SEE=34 ml), ESV (r=0.89, SEE=27 ml) and EF (r=0.88, SEE=7.2%). However, Bland-Altman plots indicated that LVG minus QGS differences for EDV generated a systematic and random error of 32±58 ml (mean±2SD), and that MRI minus QGS generated an error of 13±73 ml. In the subgroup of patients in whom ECG gating was set at eight intervals, QGS significantly underestimated EF by 7.6%±17.4% (mean±2SD) compared with LVG and by 6.3%±14.6% compared with MRI; no such underestimation was observed in the subgroup in whom ECG gating was set at 16 intervals. We conclude that in patients with ECG gating set at eight intervals, QGS systematically underestimates LV volumes and EF compared with both LVG and MRI. Since QGS also shows considerable variations around the systematic deviations, there remains uncertainty over whether an individual value determined with QGS approximates the true LV volumes and EF.
引用
收藏
页码:851 / 858
页数:7
相关论文
共 50 条
  • [1] Measurement of left ventricular volumes and ejection fraction by quantitative gated SPET, contrast ventriculography and magnetic resonance imaging: a meta-analysis
    Kondo, C
    Fukushima, K
    Kusakabe, K
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (06) : 851 - +
  • [2] Comparison of left ventricular volumes and ejection fraction measured by gated SPECT and by cine magnetic resonance imaging
    He, ZX
    Vick, GW
    Vaduganathan, P
    Verani, MS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 44A - 44A
  • [3] Comparison of gated SPECT, echocardiography and cardiac magnetic resonance imaging for the assessment of left ventricular ejection fraction and volumes
    Demir, Hakan
    Tan, Yusuf Z.
    Kozdag, Guliz
    Isgoren, Serkan
    Anik, Yonca
    Ural, Dilek
    Demirci, Ali
    Berk, Fatma
    ANNALS OF SAUDI MEDICINE, 2008, 27 (06) : 415 - 420
  • [4] Left ventricular volume and ejection fraction from quantitative gated SPECT: Comparison with gated pool SPECT and contrast ventriculography.
    Paul, AK
    Hasegawa, S
    Yoshioka, J
    Yamaguchi, W
    Tsujimura, E
    Tokita, N
    Maruyama, A
    Xiuli, M
    Nishimura, T
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 178P - 178P
  • [5] Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction - A meta-analysis
    Ioannidis, JPA
    Trikalinos, TA
    Danias, PG
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (12) : 2059 - 2068
  • [6] DETERMINATION OF LEFT-VENTRICULAR VOLUMES AND EJECTION FRACTION BY MAGNETIC-RESONANCE IMAGING
    DILWORTH, LR
    AISEN, AM
    MANCINI, GBJ
    LANDE, I
    BUDA, AJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (02) : 435 - 435
  • [7] Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction
    Sachin M. Navare
    Frans J. T. Wackers
    Yi-Hwa Liu
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 1330 - 1337
  • [8] Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction
    Navare, SM
    Wackers, FJT
    Liu, YH
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (10) : 1330 - 1337
  • [9] Gated blood-pool SPECT versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction
    François Harel
    Vincent Finnerty
    Jean Grégoire
    Bernard Thibault
    François Marcotte
    Patricia Ugolini
    Paul Khairy
    Journal of Nuclear Cardiology, 2010, 17 : 427 - 434
  • [10] Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography - A comparison with magnetic resonance imaging
    Malm, S
    Frigstad, S
    Sagberg, E
    Larsson, H
    Skjaerpe, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (05) : 1030 - 1035