Potentiometric Response of a Neutral-carrier-based Membrane to Aqueous Mercury in Cl−-rich Media

被引:0
|
作者
Yunmi Kim
Jongwon Kim
Kyoung Nam Kim
Suk-Kyu Chang
Taek Dong Chung
机构
[1] Seoul National University,Department of Chemistry
[2] Chungbuk National University,Department of Chemistry
[3] Chung-Ang University,Department of Chemistry
来源
Analytical Sciences | 2009年 / 25卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The unique potentiometric response of mercury sensors was investigated in aqueous Cl–-rich media, which are often encountered in natural, especially biological samples. The conventional neutral-carrier-based Hg(II)-ISEs are not practically useful because the Cl– concentrations in natural aqueous samples are normally too high for mercury to be present in the form of Hg2+. Negative potentiometric slopes, which are the opposite behavior of the previously reported Hg(II)-ISEs, were experimentally confirmed and quantitatively reasoned based on the aqueous solution equilibrium of Hg2+.
引用
收藏
页码:567 / 570
页数:3
相关论文
共 50 条
  • [41] A new rhodamine-based fluorescent chemosensor for mercury in aqueous media
    Liu, Yao
    Yang, Er-Bing
    Han, Rui
    Zhang, Di
    Ye, Yong
    Zhao, Yu-Fen
    CHINESE CHEMICAL LETTERS, 2014, 25 (07) : 1065 - 1068
  • [42] Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II)
    Gupta, V. K.
    Singh, A. K.
    Al Khayat, A.
    Gupta, Barkha
    ANALYTICA CHIMICA ACTA, 2007, 590 (01) : 81 - 90
  • [43] Response characteristics of lead-selective membrane sensors based on a newly synthesized quinoxaline derivatives as neutral carrier ionophores
    Ayman H. Kamel
    Abeer M. El-Naggar
    Amina A. A. Argig
    Ionics, 2017, 23 : 3497 - 3506
  • [44] Fast response and selective perchlorate polymeric membrane electrode based on bis(dibenzoylmethanato) nickel(II) complex as a neutral carrier
    Rezaei, B.
    Meghdadi, S.
    Nafisi, V.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 121 (02) : 600 - 605
  • [45] Response characteristics of lead-selective membrane sensors based on a newly synthesized quinoxaline derivatives as neutral carrier ionophores
    Kamel, Ayman H.
    El-Naggar, Abeer M.
    Argig, Amina A. A.
    IONICS, 2017, 23 (12) : 3497 - 3506
  • [46] Mercury(II)-selective membrane electrode using tetrathia-diazacyclotetradeca-2,9-diene as neutral carrier
    Singh, AK
    Bhattacharjee, G
    Singh, R
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01): : 36 - 41
  • [47] Effects of ion-carrier substituents on the potentiometric-response characteristics in anion-selective membrane electrodes based on iron porphyrins
    Shahrokhian, S
    Seifi, H
    Bagherzadeh, M
    Mousavi, SR
    CHEMPHYSCHEM, 2004, 5 (05) : 652 - 660
  • [48] A neutral carrier-based liquid membrane microelectrode for divalent putrescine cations
    Herbert R. L. Drouin
    European Biophysics Journal, 1999, 28 : 600 - 604
  • [49] Acyclic Neutral Carrier-Based Polymer Membrane Electrode for a Stimulant, Phentermine
    Takashi Katsu
    Kazuyuki Ido
    Kenji Kataoka
    Analytical Sciences, 2001, 17 : 745 - 749
  • [50] A neutral carrier-based liquid membrane microelectrode for divalent putrescine cations
    Drouin, HRL
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 1999, 28 (07): : 600 - 604