Potentiometric Response of a Neutral-carrier-based Membrane to Aqueous Mercury in Cl−-rich Media

被引:0
|
作者
Yunmi Kim
Jongwon Kim
Kyoung Nam Kim
Suk-Kyu Chang
Taek Dong Chung
机构
[1] Seoul National University,Department of Chemistry
[2] Chungbuk National University,Department of Chemistry
[3] Chung-Ang University,Department of Chemistry
来源
Analytical Sciences | 2009年 / 25卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The unique potentiometric response of mercury sensors was investigated in aqueous Cl–-rich media, which are often encountered in natural, especially biological samples. The conventional neutral-carrier-based Hg(II)-ISEs are not practically useful because the Cl– concentrations in natural aqueous samples are normally too high for mercury to be present in the form of Hg2+. Negative potentiometric slopes, which are the opposite behavior of the previously reported Hg(II)-ISEs, were experimentally confirmed and quantitatively reasoned based on the aqueous solution equilibrium of Hg2+.
引用
收藏
页码:567 / 570
页数:3
相关论文
共 50 条
  • [31] Colorimetric Detection of Mercury in Aqueous Media Based on Reaction with Dithizone
    Wu, Zihan
    Sun, Ming
    Zou, Ling
    COMPUTER AND COMPUTING TECHNOLOGIES IN AGRICULTURE IX, CCTA 2015, PT II, 2016, 479 : 111 - 116
  • [32] POTENTIOMETRIC MEASUREMENTS IN AQUEOUS, NON-AQUEOUS, AND BIOLOGICAL MEDIA USING A LEAD ION-SELECTIVE MEMBRANE ELECTRODE
    RECHNITZ, GA
    KENNY, NC
    ANALYTICAL LETTERS, 1970, 3 (05) : 259 - &
  • [33] Response characteristics of new perchlorate selective PVC membrane electrode based on a tripodal benzimidazole derivative as a neutral carrier
    Chandra, Sulekh
    Singh, Inderjeet
    Tomar, Praveen Kumar
    Malik, Amrita
    Kumar, Avdhesh
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2013, 90 (01) : 79 - 85
  • [34] POTENTIOMETRIC MEASUREMENTS IN NON-AQUEOUS MEDIA USING BROMIDE AND IODIDE ION SELECTIVE MEMBRANE ELECTRODES
    FICKLIN, WH
    GOTSCHAL.WC
    ANALYTICAL LETTERS, 1973, 6 (03) : 217 - 224
  • [35] Selectivity comparison of neutral carrier-based ion-selective optical and potentiometric sensing schemes
    Bakker, E
    ANALYTICA CHIMICA ACTA, 1997, 350 (03) : 329 - 340
  • [36] Cationic surfactant-selective potentiometric sensors based on neutral ion-pair carrier complexes
    Mahajan, RK
    Kaur, I
    Bakshi, MS
    JOURNAL OF SURFACTANTS AND DETERGENTS, 2004, 7 (02) : 131 - 134
  • [37] RESPONSE MECHANISM OF POLYMER MEMBRANE-BASED POTENTIOMETRIC POLYION SENSORS
    FU, B
    BAKKER, E
    YUN, JH
    YANG, VC
    MEYERHOFF, ME
    ANALYTICAL CHEMISTRY, 1994, 66 (14) : 2250 - 2259
  • [38] RESPONSE-TIME CURVES OF NEUTRAL CARRIER MEMBRANE-ELECTRODE OF TUBULAR SHAPE
    DEGAWA, H
    SHINOZUKA, N
    HAYANO, S
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1984, 57 (03) : 706 - 711
  • [39] RESPONSE-TIME STUDIES ON NEUTRAL CARRIER ION-SELECTIVE MEMBRANE ELECTRODES
    LINDNER, E
    TOTH, K
    PUNGOR, E
    MORF, WE
    SIMON, W
    ANALYTICAL CHEMISTRY, 1978, 50 (12) : 1627 - 1631
  • [40] A new rhodamine-based fluorescent chemosensor for mercury in aqueous media
    Yao Liu
    Er-Bing Yang
    Rui Han
    Di Zhang
    Yong Ye
    Yu-Fen Zhao
    ChineseChemicalLetters, 2014, 25 (07) : 1065 - 1068