Noninvasive quantitation of human liver steatosis using magnetic resonance and bioassay methods

被引:0
|
作者
Gaspard d’Assignies
Martin Ruel
Abdesslem Khiat
Luigi Lepanto
Miguel Chagnon
Claude Kauffmann
An Tang
Louis Gaboury
Yvan Boulanger
机构
[1] Centre hospitalier de l’Université de Montréal (CHUM),Département de radiologie
[2] Centre hospitalier de l’Université de Montréal (CHUM),Département d’anatomo
[3] Université de Montréal (UDEM),pathologie
[4] Hôpital Saint-Luc du CHUM,Département de mathématiques et de statistique
来源
European Radiology | 2009年 / 19卷
关键词
Liver steatosis; MRI; Magnetic resonance spectroscopy; Histopathology; Fat quantitation;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose was to evaluate the ability of three magnetic resonance (MR) techniques to detect liver steatosis and to determine which noninvasive technique (MR, bioassays) or combination of techniques is optimal for the quantification of hepatic fat using histopathology as a reference. Twenty patients with histopathologically proven steatosis and 24 control subjects underwent single-voxel proton MR spectroscopy (MRS; 3 voxels), dual-echo in phase/out of phase MR imaging (DEI) and diffusion-weighted MR imaging (DWI) examinations of the liver. Blood or urine bioassays were also performed for steatosis patients. Both MRS and DEI data allowed to detect steatosis with a high sensitivity (0.95 for MRS; 1 for DEI) and specificity (1 for MRS; 0.875 for DEI) but not DWI. Strong correlations were found between fat fraction (FF) measured by MRS, DEI and histopathology segmentation as well as with low density lipoprotein (LDL) and cholesterol concentrations. A Bland-Altman analysis showed a good agreement between the FF measured by MRS and DEI. Partial correlation analyses failed to improve the correlation with segmentation FF when MRS or DEI data were combined with bioassay results. Therefore, FF from MRS or DEI appear to be the best parameters to both detect steatosis and accurately quantify fat liver noninvasively.
引用
收藏
页码:2033 / 2040
页数:7
相关论文
共 50 条
  • [31] Accurate, noninvasive diagnosis of human brain tumors by using proton magnetic resonance spectroscopy
    Preul, MC
    Caramanos, Z
    Collins, DL
    Villemure, JG
    Leblanc, R
    Olivier, A
    Pokrupa, R
    Arnold, DL
    NATURE MEDICINE, 1996, 2 (03) : 323 - 325
  • [32] Noninvasive grading of glioma brain tumors using magnetic resonance imaging and deep learning methods
    Song, Guanghui
    Xie, Guanbao
    Nie, Yan
    Majid, Mohammed Sh.
    Yavari, Iman
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2023, 149 (18) : 16293 - 16309
  • [33] Parametric exploration of the liver by magnetic resonance methods
    Paul E. Sijens
    European Radiology, 2009, 19 : 2594 - 2607
  • [34] Parametric exploration of the liver by magnetic resonance methods
    Sijens, Paul E.
    EUROPEAN RADIOLOGY, 2009, 19 (11) : 2594 - 2607
  • [35] Noninvasive In Vivo Magnetic Resonance Measures of Glutathione Synthesis in Human and Rat Liver as an Oxidative Stress Biomarker
    Skamarauskas, John T.
    Oakley, Fiona
    Smith, Fiona E.
    Bawn, Carlo
    Dunn, Michael
    Vidler, Daniel S.
    Clemence, Matthew
    Blain, Peter G.
    Taylor, Roy
    Gamcsik, Michael P.
    Thelwall, Peter E.
    HEPATOLOGY, 2014, 59 (06) : 2321 - 2330
  • [36] Advanced signal processing methods for quantitation of resonances in magnetic resonance spectra
    Wang, Y
    Van Huffel, S
    Vanhamme, L
    Mastronardi, N
    Van Hecke, P
    13TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS 2000), PROCEEDINGS, 2000, : 63 - 68
  • [37] Noninvasive assessment of steatosis and viability of cold-stored human liver grafts by MRI
    Young, Liam A. J.
    Ceresa, Carlo D. L.
    Mozes, Ferenc E.
    Ellis, Jane
    Valkovic, Ladislav
    Colling, Richard
    Coussios, Constantin-C
    Friend, Peter J.
    Rodgers, Christopher T.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (06) : 3246 - 3258
  • [38] Validation of Noninvasive Methods for Detecting Hepatic Steatosis in Patients With Human Immunodeficiency Virus Infection
    Siddiqui, M. Shadab
    Patidar, Kavish R.
    Boyett, Sherry
    Smith, Paula G.
    Sanyal, Arun J.
    Sterling, Richard K.
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2015, 13 (02) : 402 - 405
  • [39] Comparison of Accuracy of Magnetic Resonance Spectroscopic and Imaging Techniques for the Liver Steatosis Assessment
    Sedivy, Petr
    Dezortova, Monika
    Burian, Martin
    Dusilova, Tereza
    Kovar, Jan
    Hajek, Milan
    CHEMICKE LISTY, 2021, 115 (01): : 46 - 53
  • [40] Obstructive sleep apnoea severity and liver steatosis measured by magnetic resonance imaging
    Trzepizur, Wojciech
    Boursier, Jerome
    Berrehare, Anna
    Le Vaillant, Marc
    Andriantsitohaina, Ramaroson
    Ducluzeau, Pierre-Henri
    Dubois, Severine
    Henni, Samir
    Abraham, Pierre
    Cales, Paul
    Aube, Christophe
    Paisant, Anita
    Gagnadoux, Frederic
    Meslier, Nicole
    Priou, Pascaline
    Oberti, Frederic
    Fouchard-Hubert, Isabelle
    Lannes, Adrien
    Girres, Sandra
    Allix, Ingrid
    Leftheriotis, Georges
    Martinez, Carmen
    Le Lay, Soazig
    Soleti, Raffaella
    Vergori, Luisa
    Chretien, Jean-Marie
    Blanchet, Odile
    Sekour, Belaid
    Hunault, Gilles
    EUROPEAN RESPIRATORY JOURNAL, 2020, 55 (01)