Noninvasive quantitation of human liver steatosis using magnetic resonance and bioassay methods

被引:0
|
作者
Gaspard d’Assignies
Martin Ruel
Abdesslem Khiat
Luigi Lepanto
Miguel Chagnon
Claude Kauffmann
An Tang
Louis Gaboury
Yvan Boulanger
机构
[1] Centre hospitalier de l’Université de Montréal (CHUM),Département de radiologie
[2] Centre hospitalier de l’Université de Montréal (CHUM),Département d’anatomo
[3] Université de Montréal (UDEM),pathologie
[4] Hôpital Saint-Luc du CHUM,Département de mathématiques et de statistique
来源
European Radiology | 2009年 / 19卷
关键词
Liver steatosis; MRI; Magnetic resonance spectroscopy; Histopathology; Fat quantitation;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose was to evaluate the ability of three magnetic resonance (MR) techniques to detect liver steatosis and to determine which noninvasive technique (MR, bioassays) or combination of techniques is optimal for the quantification of hepatic fat using histopathology as a reference. Twenty patients with histopathologically proven steatosis and 24 control subjects underwent single-voxel proton MR spectroscopy (MRS; 3 voxels), dual-echo in phase/out of phase MR imaging (DEI) and diffusion-weighted MR imaging (DWI) examinations of the liver. Blood or urine bioassays were also performed for steatosis patients. Both MRS and DEI data allowed to detect steatosis with a high sensitivity (0.95 for MRS; 1 for DEI) and specificity (1 for MRS; 0.875 for DEI) but not DWI. Strong correlations were found between fat fraction (FF) measured by MRS, DEI and histopathology segmentation as well as with low density lipoprotein (LDL) and cholesterol concentrations. A Bland-Altman analysis showed a good agreement between the FF measured by MRS and DEI. Partial correlation analyses failed to improve the correlation with segmentation FF when MRS or DEI data were combined with bioassay results. Therefore, FF from MRS or DEI appear to be the best parameters to both detect steatosis and accurately quantify fat liver noninvasively.
引用
收藏
页码:2033 / 2040
页数:7
相关论文
共 50 条
  • [21] Liver stiffness measurement by magnetic resonance elastography is not affected by hepatic steatosis
    Jie Chen
    Alina M. Allen
    Terry M. Therneau
    Jun Chen
    Jiahui Li
    Safa Hoodeshenas
    Jingbiao Chen
    Xin Lu
    Zheng Zhu
    Sudhakar K. Venkatesh
    Bin Song
    Richard L. Ehman
    Meng Yin
    European Radiology, 2022, 32 : 950 - 958
  • [22] Liver stiffness measurement by magnetic resonance elastography is not affected by hepatic steatosis
    Chen, Jie
    Allen, Alina M.
    Therneau, Terry M.
    Chen, Jun
    Li, Jiahui
    Hoodeshenas, Safa
    Chen, Jingbiao
    Lu, Xin
    Zhu, Zheng
    Venkatesh, Sudhakar K.
    Song, Bin
    Ehman, Richard L.
    Yin, Meng
    EUROPEAN RADIOLOGY, 2022, 32 (02) : 950 - 958
  • [23] A Practical Approach for a Wide Range of Liver Iron Quantitation Using a Magnetic Resonance Imaging Technique
    Hou, Ping
    Popat, Uday R.
    Lindsay, Richard J.
    Jackson, Edward F.
    Choi, Haesun
    RADIOLOGY RESEARCH AND PRACTICE, 2012, 2012
  • [24] Assessing hepatic steatosis by magnetic resonance in potential living liver donors
    Oz, Digdem Kuru
    Ellik, Zeynep
    Coruh, Ayseguel Gursoy
    Adiguzel, Mehmet
    Gumussoy, Mesut
    Kiremitci, Saba
    Kirimker, Elvan Onur
    Gokcan, Hale
    Elhan, Atilla Halil
    Balci, Deniz
    Savas, Berna
    Erden, Ayse
    Idilman, Ramazan
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2024, 30 (06): : 351 - 356
  • [25] Efficient magnetic resonance imaging methods for automated quantitation of magnetic resonance parameters from multiple samples
    Herchel Smith Laboratory for Medicinal Chemistry, University of Cambridge, School for Clinical Medicine, Robinson Way, Cambridge CB2 2PZ, United Kingdom
    Magn. Reson. Chem., 12 SPEC. ISS. (S76-S80):
  • [26] Efficient magnetic resonance imaging methods for automated quantitation of magnetic resonance parameters from multiple samples
    Evans, SD
    Nott, KP
    Kshirsagar, A
    Hall, LD
    MAGNETIC RESONANCE IN CHEMISTRY, 1997, 35 : S76 - S80
  • [27] FLOW QUANTITATION USING MAGNETIC-RESONANCE IMAGING
    PICKENS, DR
    PRICE, RR
    KULKARNI, MV
    MARTIN, V
    MAZER, M
    PARTAIN, CL
    JAMES, AE
    INVESTIGATIVE RADIOLOGY, 1985, 20 (06) : S48 - S48
  • [28] NONINVASIVE QUANTITATION OF LEFT-VENTRICULAR WALL THICKENING USING CINE MAGNETIC-RESONANCE-IMAGING WITH MYOCARDIAL TAGGING
    SAYAD, DE
    WILLETT, DWL
    BRIDGES, WH
    CHWIALKOWSKI, M
    MCCOLL, R
    PAYNE, J
    PESHOCK, RM
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (12): : 985 - &
  • [29] Noninvasive liver steatosis quantification using MRI techniques combined with blood markers
    Cesbron-Metivier, Elodie
    Roullier, Vincent
    Boursier, Jerome
    Cavaro-Menard, Christine
    Lebigot, Jerome
    Michalak, Sophie
    Cales, Paul
    Aube, Christophe
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2010, 22 (08) : 973 - 982
  • [30] Noninvasive grading of glioma brain tumors using magnetic resonance imaging and deep learning methods
    Guanghui Song
    Guanbao Xie
    Yan Nie
    Mohammed Sh. Majid
    Iman Yavari
    Journal of Cancer Research and Clinical Oncology, 2023, 149 : 16293 - 16309