Reproducibility of pulse wave velocity measurements with phase contrast magnetic resonance and applanation tonometry

被引:0
|
作者
Jonathan D. Suever
John Oshinski
Enrique Rojas-Campos
David Huneycutt
Francesca Cardarelli
Arthur E. Stillman
Paolo Raggi
机构
[1] Emory University and Georgia Institute of Technology,Wallace H. Coulter Department of Biomedical Engineering
[2] Emory University School of Medicine,Department of Radiology and Imaging Sciences
[3] Emory University School of Medicine,Department of Medicine, Division of Cardiology
关键词
Pulse wave velocity; Applanation tonometry; Cross-correlation; Phase contrast magnetic resonance;
D O I
暂无
中图分类号
学科分类号
摘要
Increased aortic pulse wave velocity (PWV) results from loss of arterial compliance and is associated with unfavorable outcomes. Applanation tonometry (AT) is the most frequently applied method to assess PWV and deduce aortic compliance. The goal of this study was to compare the reproducibility of PWV measurements obtained with: (1) cross-correlation analysis of phase contrast magnetic resonance (PCMR) velocity data, and (2) applanation tonometry (AT). PWV was measured twice with each modality in 13 normal young volunteers (controls) and 9 older patients who had undergone a CT exam to evaluate coronary artery calcium. The coefficient of variation (CoV) between measurements was computed for each modality. There was no significant difference in PWV values obtained with AT and PCMR in controls or patients. The inter-scan reproducibility of PCMR was superior to AT in the controls (CoV: 3.4 ± 2.3% vs. 6.3 ± 4.0%, P = 0.03) but not in the older patients (7.4 ± 8.0% vs. 9.9 ± 9.6%, P = 0.32). PWV values were higher in patients than controls (5.6 ± 1.2 vs. 9.7 ± 2.8, P = 0.002). PCMR and AT yielded similar values for PWV in patients and volunteers. PCMR showed a superior reproducibility in young subjects but not in older patients.
引用
收藏
页码:1141 / 1146
页数:5
相关论文
共 50 条
  • [31] Intra- and inter-observer reproducibility of masked Goldmann applanation tonometry measurements
    Trevino, Rick
    Majcher, Carolyn
    Sponsel, William Eric
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [32] Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging
    Spilt, A
    Box, FMA
    van der Geest, RJ
    Reiber, JHC
    Kunz, P
    Kamper, AM
    Blauw, GJ
    van Buchem, MA
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (01) : 1 - 5
  • [33] Velocity and volume flow rate measurements using phase contrast magnetic resonance imaging
    Korosec, FR
    Turski, PA
    INTERNATIONAL JOURNAL OF NEURORADIOLOGY, 1997, 3 (04): : 293 - 318
  • [34] The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography
    Siebenhofer, A
    Kemp, CRW
    Sutton, AJ
    Williams, B
    JOURNAL OF HUMAN HYPERTENSION, 1999, 13 (09) : 625 - 629
  • [35] The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography
    A Siebenhofer
    CRW Kemp
    AJ Sutton
    B Williams
    Journal of Human Hypertension, 1999, 13 : 625 - 629
  • [36] APPLANATION TONOMETRY-DERIVED SUBENDOCARDIAL VIABILITY RATIO, AND NOT PULSE WAVE VELOCITY, IS A DETERMINANT FACTOR OF LEFT VENTRICULAR HYPERTROPHY IN HYPERTENSION
    Rodilla, E.
    Costa, J. A.
    Perez-Lahiguera, F.
    Gonzalez, C.
    Herzig, K. H.
    Pascual, J. M.
    JOURNAL OF HYPERTENSION, 2009, 27 : S318 - S318
  • [37] Peak Velocity Measurements in Tortuous Arteries With Phase Contrast Magnetic Resonance Imaging The Effect of Multidirectional Velocity Encoding
    Schubert, Tilman
    Bieri, Oliver
    Pansini, Michele
    Stippich, Christoph
    Santini, Francesco
    INVESTIGATIVE RADIOLOGY, 2014, 49 (04) : 189 - 194
  • [38] Thoracic but not abdominal phase contrast magnetic resonance-derived aortic pulse wave velocity is elevated in patients with abdominal aortic aneurysm
    Abbas, Abeera
    Cecelja, Marina
    Hussain, Tarique
    Greil, Gerald
    Modarai, Bijan
    Waltham, Matthew
    Chowienczyk, Philip J.
    Smith, Alberto
    JOURNAL OF HYPERTENSION, 2015, 33 (05) : 1032 - 1038
  • [39] Repeatability of SphygmoCor pulse wave analysis in assessing arterial wave reflection in pregnancy using applanation tonometry
    Crilly, Michael A.
    Orme, Kirsty M.
    Henderson, Joan
    Allan, Angela J.
    Bhattacharya, Sohinee
    HYPERTENSION IN PREGNANCY, 2014, 33 (03) : 322 - 332
  • [40] Correlation of flow velocity measurements by magnetic resonance phase contrast imaging and intravascular Doppler ultrasound
    Hoppe, M
    Heverhagen, JT
    Froelich, JJ
    Kunisch-Hoppe, M
    Klose, KJ
    Wagner, HJ
    INVESTIGATIVE RADIOLOGY, 1998, 33 (08) : 427 - 432