The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography

被引:125
|
作者
Siebenhofer, A [1 ]
Kemp, CRW [1 ]
Sutton, AJ [1 ]
Williams, B [1 ]
机构
[1] Univ Leicester, Cardiovasc Res Inst, Leicester, Leics, England
关键词
applanation tonometry; reproducibility; blood pressure;
D O I
10.1038/sj.jhh.1000887
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Aim: Sphygmocardiography via applanation tonometry is a non-invasive, bedside technology which utilises tonometric analysis of the radial artery pulse wave and measurement of peripheral arterial blood pressure (BP) to derive a central arterial pulse wave, central arterial BP and related indices. The present study was designed to determine: (1) the inter-operator variability in measurements obtained using this technique; (2) the relationship between measured peripheral arterial BP and derived central arterial BP. Method: Multiple measurements were made from 25 healthy subjects (15 male), mean age 33 (s.d. 10.3) years, mean arterial BP 90 (s.d. 12) mm Hg by two trained observers at the same time of day on three separate occasions. Results: The mean inter-operator difference was 0.1 (s.d. 1.7) mm Hg for derived systolic aortic BP and 0.1 (s.d. 0.7) mm Hg for derived diastolic aortic BP (Bland and Altman analysis). Pulse wave Augmentation Index (AIx) values, ranged from -22% to +40%, with the inter-operator measurement difference being only 0.4 (s.d. 6.4)%. Buckberg ratio measurements ranged from 119% to 254%, with the inter-operator measurement difference being only 2.7 (s.d. 15.4)%. The relationship between derived central systolic BP and peripheral systolic BP readings in individual patients was not constant and showed significant variance when compared on different days (ANOVA, P = 0.03). This was not explained by any significant variance in heart rate (ANOVA, P = 0.39). Conclusion: Applanation tonometry has excellent interobserver reproducibility when used by trained observers. Moreover, the inconsistency in the relationship between peripheral and central aortic BP suggests that the former is not a perfect surrogate for the latter. Further prospective studies are required to define whether derived central aortic BP may be a better predictor of cardiovascular morbidity and mortality and the impact of different antihypertensive therapies on the relationship between peripheral and central arterial BP.
引用
收藏
页码:625 / 629
页数:5
相关论文
共 50 条
  • [1] The reproducibility of central aortic blood pressure measurements in healthy subjects using applanation tonometry and sphygmocardiography
    A Siebenhofer
    CRW Kemp
    AJ Sutton
    B Williams
    [J]. Journal of Human Hypertension, 1999, 13 : 625 - 629
  • [2] Comparison of intraocular pressure measurements in healthy subjects taken by rebound tonometry, dynamic contour tonometry and applanation tonometry at a hospital in Mexico City
    Perez Gudino, Itzel Montserrat
    Escalante-Castanon, Mariana
    Hernandez-Oteyza, Alejandra
    Jimenez-Arroyo, Jesus
    Garcia-Huerta, Magdalena
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [3] Association of central blood pressure measured by catheter and applanation tonometry
    Yamazaki, M.
    Hoshino, F.
    Oshiumi, A.
    Sagawa, Y.
    Kawano, T.
    Miyawaki, Y.
    [J]. JOURNAL OF HYPERTENSION, 2008, 26 : S29 - S29
  • [4] Peripheral blood pressure measurement is as good as applanation tonometry at predicting ascending aortic blood pressure
    Davies, JI
    Band, MM
    Pringle, S
    Ogston, S
    Struthers, AD
    [J]. JOURNAL OF HYPERTENSION, 2003, 21 (03) : 571 - 576
  • [5] CENTRAL AORTIC PRESSURE ESTIMATED BY RADIAL APPLANATION TONOMETRY IN HYPERTENSIVE PULMONARY OEDEMA
    Istratoaie, O.
    Mustafa, R.
    Donoiu, I.
    [J]. JOURNAL OF HYPERTENSION, 2010, 28 : E149 - E149
  • [6] Peripheral blood pressure by Dinamap and central blood pressure by applanation tonometry in outpatient general practice
    Santiago, Luiz Miguel
    Simoes, Ana Rita
    Miranda, Paula Ricardo
    Matias, Catarina
    Rosendo, Ines
    Constantino, Liliana
    Santos, Tiago
    da Gloria Neto, Maria
    Francisco, Maria dos Prazeres
    [J]. REVISTA PORTUGUESA DE CARDIOLOGIA, 2013, 32 (06) : 497 - 503
  • [7] Noninvasive estimation of central blood pressure and analysis of pulse waves by applanation tonometry
    Paolo Salvi
    Andrea Grillo
    Gianfranco Parati
    [J]. Hypertension Research, 2015, 38 : 646 - 648
  • [8] Noninvasive estimation of central blood pressure and analysis of pulse waves by applanation tonometry
    Salvi, Paolo
    Grillo, Andrea
    Parati, Gianfranco
    [J]. HYPERTENSION RESEARCH, 2015, 38 (10) : 646 - 648
  • [9] Evaluation of the radial artery applanation tonometry technology for continuous noninvasive blood pressure monitoring compared with central aortic blood pressure measurements in patients with multiple organ dysfunction syndrome
    Meidert, Agnes S.
    Huber, Wolfgang
    Hapfelmeier, Alexander
    Schoefthaler, Miriam
    Mueller, Johannes N.
    Langwieser, Nicolas
    Wagner, Julia Y.
    Schmid, Roland M.
    Saugel, Bernd
    [J]. JOURNAL OF CRITICAL CARE, 2013, 28 (06) : 908 - 912
  • [10] Comparison of PASCAL contour tonometry and Goldmann applanation tonometry in glaucoma patients and healthy subjects
    Barleon, L
    Hoffmann, EM
    Pfeiffer, N
    Grus, FH
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46