Protective effect of heparin-coated circuits on the platelets during cardiopulmonary bypass

被引:0
|
作者
Zhang Kailun
Hu Zhiwei
Yang Yunhai
Huang Ruqing
Fan Huiming
Sun Zongquan
机构
[1] Huazhong University of Science and Technology,Department of Cardiovasular Surgery, Xiehe Hospital, Tongji Medical College
关键词
cardiopulmonary bypass; heparin-coated circuits; platelet;
D O I
10.1007/BF02829429
中图分类号
学科分类号
摘要
To observe the protective effect of heparin-coated circuits (HCC) on the platelet function during cardiopulmonary bypass (CPB). 23 patients with heart valve replacement were studied. The system heparin dose was 3 mg/kg in the control group (n=15) and heparin-coated circuits in the HCC group (n=8). Platelet count, α-granule membrane protein-140 (GMP-140) concentrations were determined before CPB, at 60 min of CPB, 30 and 60 min after protamine administration, first 12 h after CPB, respectively. At end of CPB the arterial filters in the circuits were observed by electron microscopy. The amount of first 12-h postoperative blood loss was measured. There was significant reduction in platelet loss during and after CPB in the HCC group in contrast to the control group during CPB (P<0.05). During the first 12 h, postoperative blood loss was reduced in the HCC group as compared with that in the control group (218±61 ml, vs. 332±118 ml,P<0.05). Electron microscopy showed that in the HCC group the filter meshes and their fringes were clear and fragments of floccules were occasionally seen, without adherent cells or only few adherent cells on their surfaces, whereas several cellular and fibrous components were found to adhere to the surfaces of the filter meshes in the control group. This study indicates that heparin-coated circuits might reduce the platelet loss and activation during CPB and improve hemocompatibility of cardiopulmonary bypass equipment.
引用
收藏
页码:403 / 406
页数:3
相关论文
共 50 条
  • [41] PLATELET AND COAGULATION ACTIVATION BY HEPARIN-COATED CARDIOPULMONARY BYPASS SYSTEMS
    KOTTKEMARCHANT, K
    BORSCH, J
    MCCARTHY, P
    LAASCH, C
    BROOKS, L
    MUEHRCKE, D
    THROMBOSIS AND HAEMOSTASIS, 1995, 73 (06) : 1344 - 1344
  • [42] REDUCED COMPLEMENT AND GRANULOCYTE ACTIVATION WITH HEPARIN-COATED CARDIOPULMONARY BYPASS
    FOSSE, E
    MOEN, O
    JOHNSON, E
    SEMB, G
    BROCKMEIER, V
    MOLLNES, TE
    FAGERHOL, MK
    VENGE, P
    ANNALS OF THORACIC SURGERY, 1994, 58 (02): : 472 - 477
  • [43] Complement consumption during cardiopulmonary bypass: comparison of Duraflo II heparin-coated and uncoated circuits in fully heparinized patients
    Hamulu, Ahmet
    Discigil, Berent
    Ozbaran, Mustafa
    Calkavur, Tanzer
    Kara, Erkan
    Kokuludag, Ali
    Buket, Suat
    Bilkay, Onol
    PERFUSION-UK, 1996, 11 (04): : 333 - 337
  • [44] Eosinophil granulocyte activation and heparin-coated cardiopulmonary bypass - Reply
    Nilsson, L
    ANNALS OF THORACIC SURGERY, 1996, 61 (03): : 1039 - 1039
  • [45] Clinical use of heparin-coated cardiopulmonary bypass in coronary artery bypass grafting
    Mirow, N
    Minami, K
    KLeikamp, G
    Tenderich, G
    Puhlmann, T
    Körfer, R
    THORACIC AND CARDIOVASCULAR SURGEON, 2001, 49 (03): : 131 - 136
  • [46] Descending thoracic aortic aneurysm repair with the aid of partial cardiopulmonary bypass: Heparin-coated circuits versus nonheparin-coated circuits
    Morishita, K
    Kawaharada, N
    Fukada, J
    Hachiro, Y
    Kurimoto, Y
    Fujisawa, Y
    Saito, T
    Abe, T
    ARTIFICIAL ORGANS, 2005, 29 (04) : 300 - 305
  • [47] DO HEPARIN-COATED BYPASS CIRCUITS IMPROVE HEMODYNAMIC PERFORMANCE FOLLOWING BYPASS
    ODONNELL, AF
    MCGOVERN, EM
    CARSON, K
    MCCARTHY, J
    MCBRINN, S
    MCCARTHY, D
    MCCARTHY, A
    PHELAN, D
    NELIGAN, MC
    BRITISH JOURNAL OF SURGERY, 1995, 82 : 21 - 21
  • [48] A prospective randomized trial comparing the clinical effectiveness and biocompatibility of heparin-coated circuits and PMEA-coated circuits in pediatric cardiopulmonary bypass
    Itoh, Hideshi
    Ichiba, Shingo
    Ujike, Yoshihito
    Douguchi, Takuma
    Kasahara, Shingo
    Arai, Sadahiko
    Sano, Shunji
    PERFUSION-UK, 2016, 31 (03): : 247 - 254
  • [49] IS OXYGEN-CONSUMPTION OR LACTATE PRODUCTION ALTERED BY HEPARIN-COATED CIRCUITS DURING BYPASS
    ODONNELL, AF
    MCGOVERN, EM
    CARSON, K
    MCCARTHY, J
    MCBRINN, S
    MCCARTHY, D
    MCCARTHY, A
    PHELAN, D
    NELIGAN, MC
    BRITISH JOURNAL OF SURGERY, 1995, 82 : 21 - 21
  • [50] High and low heparin dose with heparin-coated cardiopulmonary bypass: Activation of complement and granulocytes
    Ovrum, E
    Mollnes, TE
    Fosse, E
    Holen, EA
    Tangen, G
    Ringdal, MAL
    Videm, V
    ANNALS OF THORACIC SURGERY, 1995, 60 (06): : 1755 - 1761