Complement consumption during cardiopulmonary bypass: comparison of Duraflo II heparin-coated and uncoated circuits in fully heparinized patients

被引:5
|
作者
Hamulu, Ahmet [1 ]
Discigil, Berent [1 ]
Ozbaran, Mustafa [1 ]
Calkavur, Tanzer [1 ]
Kara, Erkan [1 ]
Kokuludag, Ali [1 ]
Buket, Suat [1 ]
Bilkay, Onol [1 ]
机构
[1] Ege Univ, Fac Med, Dept Cardiovasc Surg, Izmir, Turkey
来源
PERFUSION-UK | 1996年 / 11卷 / 04期
关键词
D O I
10.1177/026765919601100406
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Heparin attachment to synthetic surfaces is one means of improving the biocompatibility of clinically used cardiopulmonary bypass (CPB) circuits. To assess the effect of heparin-coated circuits on complement consumption during CPB, 40 patients undergoing elective myocardial revascularization were prospectively randomized either to a group in which a completely Duraflo II heparin-coated circuit was used for perfusion (heparin-coated Group, n = 20 patients) or to a control group (n = 20 patients) in which an uncoated, but otherwise standard circuit was used. Full systemic heparinization was induced (activated clotting time, 480 seconds) in all the patients included in the study, regardless of which perfusion circuit was used. The two groups did not differ significantly in terms of bodyweight, aortic crossclamp and extracorporeal circulation times. No patient had difficulty in weaning from bypass and the postoperative period was uneventful in all patients. Concentrations of C3 and C4 were found to be within the 'normal' range in the prebypass period in both groups. There were no significant intergroup differences with regard to C3 and C4 consumption during CPB. We conclude that Duraflo II heparin-coated circuits have no effect in reducing complement consumption during CPB in fully heparinized patients.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 50 条
  • [1] COMPLEMENT ACTIVATION DURING EXTRACORPOREAL-CIRCULATION - IN-VITRO COMPARISON OF DURAFLO-II HEPARIN-COATED AND UNCOATED OXYGENATOR CIRCUITS
    SVENNEVIG, JL
    GEIRAN, OR
    KARLSEN, H
    PEDERSEN, T
    MOLLNES, TE
    KONGSGARD, U
    FROYSAKER, T
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 106 (03): : 466 - 472
  • [2] Heparin-coated circuits (Duraflo II) with reduced versus full anticoagulation during coronary artery bypass surgery
    Ovrum, E
    Tangen, G
    Oystese, R
    Ringdal, MAL
    Istad, R
    JOURNAL OF CARDIAC SURGERY, 2003, 18 (02) : 140 - 146
  • [3] Heparin-coated circuits reduce complement activation and inflammatory response to cardiopulmonary bypass
    Tamim, M
    Demircin, E
    Guvener, M
    Peker, O
    Yilmaz, M
    PANMINERVA MEDICA, 1999, 41 (03) : 193 - 198
  • [4] BIOCOMPATIBILITY OF HEPARIN-COATED CIRCUITS USED IN CARDIOPULMONARY BYPASS
    PEKNA, M
    BOROWIEC, J
    FAGERHOL, MK
    VENGE, P
    THELIN, S
    SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 28 (01): : 5 - 11
  • [5] Protective effect of heparin-coated circuits on the platelets during cardiopulmonary bypass
    Zhang Kailun
    Hu Zhiwei
    Yang Yunhai
    Huang Ruqing
    Fan Huiming
    Sun Zongquan
    Current Medical Science, 2003, 23 (4) : 403 - 406
  • [6] Heparin-coated bypass circuits in cardiopulmonary bypass: Improved biocompatibility or not
    Levy, M
    Hartman, AR
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1996, 53 : S81 - S87
  • [7] The impact of heparin-coated circuits on hemodynamics during and after cardiopulmonary bypass
    de Vroege, R
    Huybregts, R
    van Oeveren, W
    van Klarenbosch, J
    Linley, G
    Mutlu, J
    Jansen, E
    Hack, E
    Eijsman, L
    Wildevuur, C
    ARTIFICIAL ORGANS, 2005, 29 (06) : 490 - 497
  • [8] Heparin-coated cardiopulmonary bypass circuits in coronary bypass surgery
    Horimoto, H
    Kondo, K
    Asada, K
    Sasaki, S
    ARTIFICIAL ORGANS, 1996, 20 (08) : 936 - 940
  • [9] Protective effect of heparin-coated circuits on the platelets during cardiopulmonary bypass
    Zhang, Kailun
    Hu, Zhiwei
    Yang, Yunhai
    Huang, Ruqing
    Fan, Huiming
    Sun, Zongquan
    Journal of Huazhong University of Science and Technology - Medical Science, 2003, 23 (04): : 403 - 406
  • [10] Protective Effect of Heparin-coated Circuits on the Platelets during Cardiopulmonary Bypass
    张凯伦
    胡志伟
    杨运海
    黄如清
    范慧敏
    孙宗全
    华中科技大学学报(医学英德文版), 2003, (04) : 403 - 406