Complement consumption during cardiopulmonary bypass: comparison of Duraflo II heparin-coated and uncoated circuits in fully heparinized patients

被引:5
|
作者
Hamulu, Ahmet [1 ]
Discigil, Berent [1 ]
Ozbaran, Mustafa [1 ]
Calkavur, Tanzer [1 ]
Kara, Erkan [1 ]
Kokuludag, Ali [1 ]
Buket, Suat [1 ]
Bilkay, Onol [1 ]
机构
[1] Ege Univ, Fac Med, Dept Cardiovasc Surg, Izmir, Turkey
来源
PERFUSION-UK | 1996年 / 11卷 / 04期
关键词
D O I
10.1177/026765919601100406
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Heparin attachment to synthetic surfaces is one means of improving the biocompatibility of clinically used cardiopulmonary bypass (CPB) circuits. To assess the effect of heparin-coated circuits on complement consumption during CPB, 40 patients undergoing elective myocardial revascularization were prospectively randomized either to a group in which a completely Duraflo II heparin-coated circuit was used for perfusion (heparin-coated Group, n = 20 patients) or to a control group (n = 20 patients) in which an uncoated, but otherwise standard circuit was used. Full systemic heparinization was induced (activated clotting time, 480 seconds) in all the patients included in the study, regardless of which perfusion circuit was used. The two groups did not differ significantly in terms of bodyweight, aortic crossclamp and extracorporeal circulation times. No patient had difficulty in weaning from bypass and the postoperative period was uneventful in all patients. Concentrations of C3 and C4 were found to be within the 'normal' range in the prebypass period in both groups. There were no significant intergroup differences with regard to C3 and C4 consumption during CPB. We conclude that Duraflo II heparin-coated circuits have no effect in reducing complement consumption during CPB in fully heparinized patients.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 50 条
  • [21] Heparin-coated circuits reduce the formation of TNF alpha during cardiopulmonary bypass
    Yamada, H
    Kudoh, I
    Hirose, Y
    Toyoshima, M
    Abe, H
    Kurahashi, K
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1996, 40 (03) : 311 - 317
  • [22] Cardiopulmonary bypass with heparin-coated circuits and reduced systemic anticoagulation
    Kuitunen, AH
    Heikkila, LJ
    Salmenpera, MT
    ANNALS OF THORACIC SURGERY, 1997, 63 (02): : 438 - 444
  • [23] Pro: Heparin-coated circuits should be used for cardiopulmonary bypass
    Jessen, Michael E.
    ANESTHESIA AND ANALGESIA, 2006, 103 (06): : 1365 - 1369
  • [24] REDUCED COMPLEMENT ACTIVATION AND IMPROVED POSTOPERATIVE PERFORMANCE AFTER CARDIOPULMONARY BYPASS WITH HEPARIN-COATED CIRCUITS
    JANSEN, PGM
    TEVELTHUIS, H
    HUYBREGTS, RAJM
    PAULUS, R
    BULDER, ER
    VANDERSPOEL, HI
    BEZEMER, PD
    SLAATS, EH
    EIJSMAN, L
    WILDEVUUR, CRH
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (03): : 829 - 834
  • [25] Effects of Duraflo II heparin-coated cardiopulmonary bypass circuits on the coagulation system, endothelial damage, and cytokine release in patients with cardiac operation employing aprotinin and steroids
    Inui, K
    Shimazaki, Y
    Watanabe, T
    Takahashi, T
    Minowa, T
    Takeda, H
    Yanagawa, N
    Sotoda, Y
    ARTIFICIAL ORGANS, 1999, 23 (12) : 1107 - 1112
  • [26] Cardiopulmonary bypass with modified fluid gelatin and heparin-coated circuits
    Jansen, PGM
    teVelthuis, H
    Wildevuur, WR
    Huybregts, MAJM
    Bulder, ER
    vanderSpoel, HI
    Sturk, A
    Eijsman, L
    Wildevuur, CRH
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 (01) : 13 - 19
  • [27] HEPARIN-COATED CIRCUITS REDUCE THE INFLAMMATORY RESPONSE TO CARDIOPULMONARY BYPASS
    GU, YJ
    VANOEVEREN, W
    AKKERMAN, C
    BOONSTRA, PW
    HUYZEN, RJ
    WILDEVUUR, CRH
    ANNALS OF THORACIC SURGERY, 1993, 55 (04): : 917 - 922
  • [28] Biocompatibility reflected by haemostasis variables during cardiopulmonary bypass using heparin-coated circuits
    Borowiec, J
    Bagge, L
    Saldeen, T
    Thelin, S
    THORACIC AND CARDIOVASCULAR SURGEON, 1997, 45 (04): : 163 - 167
  • [29] Experimental studies on three types of heparin-coated cardiopulmonary bypass circuits
    Baba, T
    Morisita, K
    Sakata, J
    Ito, T
    Hachiro, Y
    Kazui, T
    Abe, A
    Komatu, S
    ARTIFICIAL ORGANS, 1997, 21 (07) : 779 - 781
  • [30] High and low heparin dose with heparin-coated cardiopulmonary bypass: Activation of complement and granulocytes
    Ovrum, E
    Mollnes, TE
    Fosse, E
    Holen, EA
    Tangen, G
    Ringdal, MAL
    Videm, V
    ANNALS OF THORACIC SURGERY, 1995, 60 (06): : 1755 - 1761