Nafion based amperometric hydrogen sensor

被引:0
|
作者
G. Velayutham
C. Ramesh
N. Murugesan
V. Manivannan
K. S. Dhathathreyan
G. Periaswami
机构
[1] SPIC Science Foundation,Centre For Electrochemical & Energy Research
[2] Indira Gandhi Centre for Atomic Research,Materials Chemistry Division
来源
Ionics | 2004年 / 10卷
关键词
Hydrogen; Polymer; Platinum; Argon; Palladium;
D O I
暂无
中图分类号
学科分类号
摘要
A Nafion based amperometric hydrogen sensor that operates at room temperature has been developed. The electrolyte used in the sensor is Nafion 117, which is a proton conducting solid polymer electrolyte. Palladium catalyst was used on the sensing side and platinum supported on carbon on the air side. The sensor functions as fuel cell, H2/Pd//Nafion//Pt/O2 and the short circuit current is measured. The short circuit current is found to be linear with respect to concentration of hydrogen on the sensing side. The sensor is able to detect the concentration of hydrogen in argon down to ppb level. Details of assembly of the sensor, response behavior and applications are discussed.
引用
收藏
页码:63 / 67
页数:4
相关论文
共 50 条
  • [31] A novel amperometric biosensor for determination of hydrogen peroxide based on nafion and polythionine as well as gold nanoparticles and gelatin as matrixes
    Zhu, Q
    Yuan, R
    Chai, YQ
    Zhuo, Y
    Zhang, Y
    Li, XL
    Wang, N
    ANALYTICAL LETTERS, 2006, 39 (03) : 483 - 494
  • [32] Solid-state amperometric hydrogen sensor using Pt/C/Nafion composite electrodes prepared by a hot-pressed method
    Liu, YC
    Hwang, BJ
    Tzeng, IJ
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2002, 149 (11) : H173 - H178
  • [33] A two electrode C-NiO Nafion amperometric sensor for NO2 detection
    Fort, A.
    Lotti, C.
    Mugnaini, M.
    Palombari, R.
    Rocchi, S.
    Vignoli, V.
    MICROELECTRONICS JOURNAL, 2009, 40 (09) : 1308 - 1312
  • [34] A two electrode C-NiO Nafion® amperometric sensor for NO2 detection
    Fort, A.
    Lotti, C.
    Mugnaini, M.
    Palmerini, C. A.
    Palombari, R.
    Rocchi, S.
    Tondi, L.
    Vignoli, V.
    2007 2ND INTERNATIONAL WORKSHOP ON ADVANCES IN SENSORS AND INTERFACE, 2007, : 30 - +
  • [35] Amperometric hydrogen sensor for high-temperature water
    Kriksunov, LB
    Macdonald, DD
    SENSORS AND ACTUATORS B-CHEMICAL, 1996, 32 (01) : 57 - 60
  • [36] A pulse amperometric sensor for the measurement of atmospheric hydrogen peroxide
    Huang, HL
    Dasgupta, PK
    Genfa, Z
    Wang, J
    ANALYTICAL CHEMISTRY, 1996, 68 (13) : 2062 - 2066
  • [37] Amperometric nitrogen dioxide gas sensor based on PAn/Au/Nafion® prepared by constant current and cyclic voltammetry methods
    Do, JS
    Chang, WB
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 101 (1-2) : 97 - 106
  • [38] Amperometric determination of hydrogen peroxide residue in beverages using a Nafion modified palladium electrode
    Chuan-Liang Hsu
    Hung-Der Jang
    Ming-Sheng Su
    Ku-Shang Chang
    Yung-Sheng Huang
    European Food Research and Technology, 2008, 226 : 809 - 815
  • [39] Selective amperometric sensing of hydrogen peroxide with Nafion/copper particulates chemically modified electrode
    Kumar, Annamalai Senthil
    Sornambikai, Sundaram
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2009, 48 (07): : 940 - 945
  • [40] A Prussian blue-based amperometric sensor for the determination of hydrogen peroxide residues in milk
    Jianfeng Ping
    Xiuling Mao
    Kai Fan
    Dongyang Li
    Shiping Ru
    Jian Wu
    Yibin Ying
    Ionics, 2010, 16 : 523 - 527