Nafion based amperometric hydrogen sensor

被引:0
|
作者
G. Velayutham
C. Ramesh
N. Murugesan
V. Manivannan
K. S. Dhathathreyan
G. Periaswami
机构
[1] SPIC Science Foundation,Centre For Electrochemical & Energy Research
[2] Indira Gandhi Centre for Atomic Research,Materials Chemistry Division
来源
Ionics | 2004年 / 10卷
关键词
Hydrogen; Polymer; Platinum; Argon; Palladium;
D O I
暂无
中图分类号
学科分类号
摘要
A Nafion based amperometric hydrogen sensor that operates at room temperature has been developed. The electrolyte used in the sensor is Nafion 117, which is a proton conducting solid polymer electrolyte. Palladium catalyst was used on the sensing side and platinum supported on carbon on the air side. The sensor functions as fuel cell, H2/Pd//Nafion//Pt/O2 and the short circuit current is measured. The short circuit current is found to be linear with respect to concentration of hydrogen on the sensing side. The sensor is able to detect the concentration of hydrogen in argon down to ppb level. Details of assembly of the sensor, response behavior and applications are discussed.
引用
收藏
页码:63 / 67
页数:4
相关论文
共 50 条
  • [21] Room temperature hydrogen sensor based on Nafion and Pd/CF sensing electrode
    Li, Weijia
    Huang, Lingchu
    Sun, Huaiyuan
    Wang, Bin
    Lu, Qi
    Liang, Xishuang
    Liu, Fangmeng
    Liu, Fengmin
    Sun, Peng
    Lu, Geyu
    Sensors and Actuators B: Chemical, 2022, 366
  • [22] Room temperature hydrogen sensor based on Nafion and Pd/CF sensing electrode
    Li, Weijia
    Huang, Lingchu
    Sun, Huaiyuan
    Wang, Bin
    Lu, Qi
    Liang, Xishuang
    Liu, Fangmeng
    Liu, Fengmin
    Sun, Peng
    Lu, Geyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 366
  • [23] Amperometric sensor for selective and stable hydrogen measurement
    Chao, YT
    Yao, S
    Buttner, WJ
    Stetter, JR
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 106 (02) : 784 - 790
  • [24] Amperometric Hydrogen Sensor Based on Solid Polymer Electrolyte and Titanium Foam Electrode
    Gao, Wanshuo
    Zhi, Zinan
    Fan, Shurui
    Hua, Zhongqiu
    Li, Haoyi
    Pan, Xuanyue
    Sun, Wentao
    Gao, Huicheng
    ACS OMEGA, 2022, : 24895 - 24902
  • [25] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Yazhen Wang
    Bin Song
    Junhui Xu
    Shengshui Hu
    Microchimica Acta, 2015, 182 : 711 - 718
  • [26] Hydrogen peroxide-sensitive amperometric sensor based on manganese dioxide nanoparticles
    E. A. Dontsova
    I. A. Budashov
    A. V. Eremenko
    I. N. Kurochkin
    Nanotechnologies in Russia, 2008, 3 (7-8): : 510 - 520
  • [27] Hydrogen Peroxide-Sensitive Amperometric Sensor Based on Manganese Dioxide Nanoparticles
    Dontsova, E. A.
    Budashov, I. A.
    Eremenko, A. V.
    Kurochkin, I. N.
    NANOTECHNOLOGIES IN RUSSIA, 2008, 3 (7-8): : 510 - 520
  • [28] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Wang, Yazhen
    Song, Bin
    Xu, Junhui
    Hu, Shengshui
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 711 - 718
  • [29] Reusable hydrazine amperometric sensor based on Nafion®-coated TiO2-carbon nanotube modified electrodell
    Kim, Sung Phil
    Choi, Hyun Chul
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 424 - 429
  • [30] Sol-gel-derived amperometric biosensor for hydrogen peroxide based on methylene green incorporated in Nafion film
    Wang, BQ
    Dong, SJ
    TALANTA, 2000, 51 (03) : 565 - 572