Nafion based amperometric hydrogen sensor

被引:0
|
作者
G. Velayutham
C. Ramesh
N. Murugesan
V. Manivannan
K. S. Dhathathreyan
G. Periaswami
机构
[1] SPIC Science Foundation,Centre For Electrochemical & Energy Research
[2] Indira Gandhi Centre for Atomic Research,Materials Chemistry Division
来源
Ionics | 2004年 / 10卷
关键词
Hydrogen; Polymer; Platinum; Argon; Palladium;
D O I
暂无
中图分类号
学科分类号
摘要
A Nafion based amperometric hydrogen sensor that operates at room temperature has been developed. The electrolyte used in the sensor is Nafion 117, which is a proton conducting solid polymer electrolyte. Palladium catalyst was used on the sensing side and platinum supported on carbon on the air side. The sensor functions as fuel cell, H2/Pd//Nafion//Pt/O2 and the short circuit current is measured. The short circuit current is found to be linear with respect to concentration of hydrogen on the sensing side. The sensor is able to detect the concentration of hydrogen in argon down to ppb level. Details of assembly of the sensor, response behavior and applications are discussed.
引用
收藏
页码:63 / 67
页数:4
相关论文
共 50 条
  • [1] Nafion based amperometric hydrogen sensor
    Velayutham, G
    Ramesh, C
    Murugesan, N
    Manivannan, V
    Dhathathreyan, KS
    Periaswami, G
    IONICS, 2004, 10 (1-2) : 63 - 67
  • [2] Improved Nafion-based amperometric sensor for hydrogen in argon
    Ramesh, C.
    Murugesan, N.
    Krishnaiah, M. V.
    Ganesan, V.
    Periaswami, G.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2008, 12 (09) : 1109 - 1116
  • [3] Improved Nafion-based amperometric sensor for hydrogen in argon
    C. Ramesh
    N. Murugesan
    M. V. Krishnaiah
    V. Ganesan
    G. Periaswami
    Journal of Solid State Electrochemistry, 2008, 12 : 1109 - 1116
  • [4] Amperometric hydrogen gas sensor based on Pt/C/Nafion electrode and ionic electrolyte
    Zhi, Zinan
    Gao, Wanshuo
    Yang, Jiawei
    Geng, Chong
    Yang, Boxuan
    Tian, Chen
    Fan, Shurui
    Li, Haoyi
    Li, Jinpo
    Hua, Zhongqiu
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 367
  • [5] Amperometric hydrogen sensor based on PtxPdy/Nafion electrode prepared by Takenata-Torikai method
    Weng, Yu-Ching
    Hung, Kun-Chieh
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (01) : 161 - 167
  • [6] AMPEROMETRIC OXYGEN SENSOR USING NAFION MEMBRANE
    KUWATA, S
    MIURA, N
    YAMAZOE, N
    NIPPON KAGAKU KAISHI, 1989, (10) : 1700 - 1705
  • [7] An amperometric NO2 gas sensor based on Pt/Nafion® Electrode
    Ho, KC
    Hung, WT
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (01) : 11 - 16
  • [8] Influence of Humidity on Parameters of Amperometric Sensor with Nafion Membrane
    Gebicki, J.
    Chachulski, B.
    SENSOR LETTERS, 2009, 7 (02) : 167 - 176
  • [9] Influence of aprotic solvent on selectivity of an amperometric sensor with Nafion membrane
    Chachulski, B
    Gebicki, J
    ELECTROANALYSIS, 2006, 18 (05) : 433 - 439
  • [10] Influence of aprotic solvent on a signal of an amperometric sensor with Nafion® membrane
    Chachulski, B.
    Gebicki, J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 119 (02): : 435 - 440