An amperometric hydrogen peroxide biosensor based on immobilization of horseradish peroxidase on an electrode modified with magnetic dextran microspheres

被引:0
|
作者
Hai-Li Zhang
Guo-Song Lai
De-Yan Han
Ai-Min Yu
机构
[1] Hubei Normal University,Hubei Key Laboratory of Bioanalytical Technique, Department of Chemistry and Environmental Engineering
[2] Murdoch University,School of Chemical and Mathematical Sciences
来源
关键词
Horseradish peroxidase; Hydrogen peroxide; Magnetic microspheres; Biosensor;
D O I
暂无
中图分类号
学科分类号
摘要
A new kind of magnetic dextran microsphere (MDMS) with uniform shape and narrow diameter distribution has been prepared from magnetic iron nanoparticles and dextran. Horseradish peroxidase (HRP) was successfully immobilized on the surface of an MDMS-modified glassy-carbon electrode (GCE), and the immobilized HRP displayed excellent electrocatalytic activity in the reduction of H2O2 in the presence of the mediator hydroquinone (HQ). The effects of experimental variables such as the concentration of HQ, solution pH, and the working potential were investigated for optimum analytical performance. This biosensor had a fast response to H2O2 of less than 10 s and an excellent linear relationship was obtained in the concentration range 0.20 μmol L−1–0.68 mmol L−1, with a detection limit of 0.078 μmol L−1 (S/N = 3) under the optimum conditions. The response showed Michaelis–Menten behavior at larger H2O2 concentrations, and the apparent Michaelis–Menten constant \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ K^{{app}}_{M} $$\end{document} was estimated to be 1.38 mmol L−1. Moreover, the selectivity, stability, and reproducibility of the biosensor were evaluated, with satisfactory results.
引用
收藏
页码:971 / 977
页数:6
相关论文
共 50 条
  • [21] Hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase on γ-Al2O3 nanoparticles/chitosan film-modified electrode
    Liu, Xiaojuan
    Luo, Liqiang
    Ding, Yaping
    Xu, Yanhong
    Li, Fei
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2011, 15 (03) : 447 - 453
  • [22] A third-generation biosensor for hydrogen peroxide based on the immobilization of horseradish peroxidase on a disposable carbon nanotubes modified screen-printed electrode
    Xu, Shuxia
    Qin, Xiaojiao
    Zhang, Xinfeng
    Zhang, Chengxiao
    MICROCHIMICA ACTA, 2015, 182 (7-8) : 1241 - 1246
  • [23] Hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase on γ-Al2O3 nanoparticles/chitosan film-modified electrode
    Xiaojuan Liu
    Liqiang Luo
    Yaping Ding
    Yanhong Xu
    Fei Li
    Journal of Solid State Electrochemistry, 2011, 15 : 447 - 453
  • [24] Immobilized horseradish peroxidase on Nafion-cysteine modified gold electrode as a biosensor for hydrogen peroxide
    Ghourchian, Hedayatollah
    Hong, Jun
    Hamidi, Faezeh
    CLINICAL BIOCHEMISTRY, 2011, 44 (13) : S96 - S96
  • [25] An Amperometric Biosensor Based on Direct Immobilization of Horseradish Peroxidase on Electrochemically Reduced Graphene Oxide Modified Screen Printed Carbon Electrode
    Palanisamy, Selvakumar
    Unnikrishnan, Binesh
    Chen, Shen-Ming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (09): : 7935 - 7947
  • [26] Amperometric biosensor for hydrogen peroxide based on the co-electrodeposition of horseradish peroxidase and methylene blue on an ITO electrode modified with an anodic aluminum oxide template
    Hui Yao
    Huan Liu
    Mei-jiao Sun
    Lei Gong
    Microchimica Acta, 2012, 177 : 31 - 37
  • [27] Amperometric biosensor for hydrogen peroxide, using supramolecularly immobilized horseradish peroxidase on the β-cyclodextrin-coated gold electrode
    Camacho, Conrado
    Matias, Juan C.
    Chico, Belkis
    Cao, Roberto
    Gomez, Leissy
    Simpson, Benjamin K.
    Villalonga, Reynaldo
    ELECTROANALYSIS, 2007, 19 (24) : 2538 - 2542
  • [28] Amperometric biosensor for hydrogen peroxide based on the co-electrodeposition of horseradish peroxidase and methylene blue on an ITO electrode modified with an anodic aluminum oxide template
    Yao, Hui
    Liu, Huan
    Sun, Mei-jiao
    Gong, Lei
    MICROCHIMICA ACTA, 2012, 177 (1-2) : 31 - 37
  • [29] An amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene blue on a β-type zeolite modified electrode
    Liu, BH
    Liu, ZJ
    Chen, DD
    Kong, JL
    Deng, JQ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (06): : 539 - 544
  • [30] An amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene blue on a β-type zeolite modified electrode
    Baohong Liu
    Zhenjiu Liu
    Dandan Chen
    Jilie Kong
    Jiaqi Deng
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 539 - 544