An amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene blue on a β-type zeolite modified electrode

被引:0
|
作者
Baohong Liu
Zhenjiu Liu
Dandan Chen
Jilie Kong
Jiaqi Deng
机构
[1] Department of Chemistry,
[2] Fudan University,undefined
[3] Shanghai 200433,undefined
[4] People’s Republic of China,undefined
关键词
Enzyme; H2O2; Hydrogen Peroxide; Zeolite; Detection Limit;
D O I
暂无
中图分类号
学科分类号
摘要
A new biosensor for the amperometric detection of hydrogen peroxide was developed based on the co-immobilization of horseradish peroxidase (HRP) and methylene blue on a β-type zeolite modified glassy carbon electrode without the commonly used bovine serum albumin-glutaraldehyde. The intermolecular interaction between enzyme and zeolite matrix was investigated using FT-IR. The cyclic voltammetry and amperometric measurement demonstrated that methylene blue co-immobilized with HRP in this way displayed good stability and could efficiently transfer electrons between immobilized HRP and the electrode. The sensor responded rapidly to H2O2 in the linear range from 2.5 × 10–6 to 4.0 × 10–3 M with a detection limit of 0.3 μM. The sensor was stable in continuous operation.
引用
收藏
页码:539 / 544
页数:5
相关论文
共 50 条
  • [1] An amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene blue on a β-type zeolite modified electrode
    Liu, BH
    Liu, ZJ
    Chen, DD
    Kong, JL
    Deng, JQ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (06): : 539 - 544
  • [2] An amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene blue on a carbon nanotubes modified electrode
    Xu, JZ
    Zhu, JJ
    Wu, Q
    Hu, Z
    Chen, HY
    ELECTROANALYSIS, 2003, 15 (03) : 219 - 224
  • [3] A reagentless amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene green in a modified zeolite matrix
    Liu, BH
    Yan, F
    Kong, JL
    Deng, JQ
    ANALYTICA CHIMICA ACTA, 1999, 386 (1-2) : 31 - 39
  • [4] Amperometric biosensor for hydrogen peroxide based on immobilization of horseradish peroxidase on methylene blue modified graphite electrode
    Lin, XQ
    Chen, J
    Chen, ZH
    ELECTROANALYSIS, 2000, 12 (04) : 306 - 310
  • [5] Amperometric biosensor for hydrogen peroxide based on the co-electrodeposition of horseradish peroxidase and methylene blue on an ITO electrode modified with an anodic aluminum oxide template
    Hui Yao
    Huan Liu
    Mei-jiao Sun
    Lei Gong
    Microchimica Acta, 2012, 177 : 31 - 37
  • [6] Amperometric biosensor for hydrogen peroxide based on the co-electrodeposition of horseradish peroxidase and methylene blue on an ITO electrode modified with an anodic aluminum oxide template
    Yao, Hui
    Liu, Huan
    Sun, Mei-jiao
    Gong, Lei
    MICROCHIMICA ACTA, 2012, 177 (1-2) : 31 - 37
  • [7] An amperometric hydrogen peroxide biosensor based on immobilization of horseradish peroxidase on an electrode modified with magnetic dextran microspheres
    Hai-Li Zhang
    Guo-Song Lai
    De-Yan Han
    Ai-Min Yu
    Analytical and Bioanalytical Chemistry, 2008, 390 : 971 - 977
  • [8] An amperometric hydrogen peroxide biosensor based on immobilization of horseradish peroxidase on an electrode modified with magnetic dextran microspheres
    Zhang, Hai-Li
    Lai, Guo-Song
    Han, De-Yan
    Yu, Ai-Min
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (03) : 971 - 977
  • [9] Hydrogen peroxide sensitive amperometric biosensor based on horseradish peroxidase entrapped in a polypyrrole electrode
    Razola, SS
    Ruiz, BL
    Diez, NM
    Mark, HB
    Kauffmann, JM
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12): : 921 - 928