The correlation between clinical radiological outcome and contact state of implant and femur using three-dimensional templating software in cementless total hip arthroplasty

被引:24
|
作者
Inoue D. [1 ]
Kabata T. [1 ]
Maeda T. [1 ]
Kajino Y. [1 ]
Yamamoto T. [1 ]
Takagi T. [1 ]
Ohmori T. [1 ]
Tsuchiya H. [1 ]
机构
[1] Department of Orthopaedic Surgery, Graduate School of Medical Science, Kanazawa University, 13-1 Takaramachi, Kanazawa, 920-8641, Ishikawa
基金
日本学术振兴会;
关键词
Density mapping; Radiological outcome; Three-dimensional templating software; Total hip arthroplasty;
D O I
10.1007/s00590-016-1796-5
中图分类号
学科分类号
摘要
Background: Initial fixation is a key factor in the success of cementless THA using a tapered wedge stem. The purpose of this study was to use three-dimensional templating software to examine the correlation between quantitative contact state and important clinical radiological outcomes, specifically stem subsidence, stress shielding, and cortical hypertrophy. Methods: We conducted a retrospective consecutive review of 75 hips in 70 patients over a minimum 3-year follow-up period. X-rays and CT scans were investigated to assess preoperative planning, quantify the contact state of implant and femur, and assess stem alignment, stem subsidence, stress shielding, and cortical hypertrophy. We evaluated the correlation between radiological outcomes and three-dimensional quantitative contact state according to Gruen Zone in each Dorr classification. Results: Density mapping indicated that stem subsidence increased postoperatively if the stem had less cortical contact in the middle to distal portion of the implant in terms of initial fixation. Cases having too much cortical contact in the distal portion of the implant tended to have increased stress shielding. We found no correlation between cortical hypertrophy and the contact state of implant and femur. Conclusions: Density mapping with three-dimensional templating software can be useful in predicting stem subsidence and stress shielding following cementless THA with a tapered wedge stem. Further analysis is required to accurately depict the correlation between cortical hypertrophy and the contact state. © 2016, Springer-Verlag France.
引用
收藏
页码:591 / 598
页数:7
相关论文
共 50 条
  • [31] Clinical three-dimensional anatomy of the femur considering navigation-aided surgery of total knee arthroplasty in Japanese patients
    Sato, Atsushi
    Takagi, Hiroshi
    Koya, Takayuki
    Orias, Alejandro A. Espinoza
    Kanzaki, Koji
    Inoue, Nozomu
    KNEE, 2023, 41 : 214 - 220
  • [32] The Accuracy of CT-Based Three-Dimensional Templating in Predicting Implant Sizes in Patients Undergoing Robot-Assisted Total Knee Arthroplasty
    Adkar, Neeraj
    Patil, Mangesh
    Vaidya, Swapnil
    Kumbar, Rajendra
    Kerhalkar, Ravi
    Mote, Girish
    Thareja, Satwik
    Sadalagi, Prajwal
    Bajwa, Supreet
    INDIAN JOURNAL OF ORTHOPAEDICS, 2024, 58 (10) : 1388 - 1394
  • [33] Femoral revision in total hip arthroplasty using a cementless modular stem: clinical and radiological results with a 8-year follow-up
    David Spranz
    David Skrobek
    Jannis Randoll
    Stefan Kinkel
    Christian Merle
    Tilman Walker
    Tobias Renkawitz
    Tobias Reiner
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 1369 - 1377
  • [34] Study on the correlation between early three-dimensional gait analysis and clinical efficacy after robot-assisted total knee arthroplasty
    He, Rui
    Xiong, Ran
    Sun, Mao-Lin
    Yang, Jun-Jun
    Chen, Hao
    Yang, Peng-Fei
    Yang, Liu
    CHINESE JOURNAL OF TRAUMATOLOGY, 2023, 26 (02) : 83 - 93
  • [35] Study on the correlation between early three-dimensional gait analysis and clinical efficacy after robot-assisted total knee arthroplasty
    He Rui
    Xiong Ran
    Sun Mao-Lin
    Yang Jun-Jun
    Chen Hao
    Yang Peng-Fei
    Yang Liu
    中华创伤杂志英文版, 2023, 26 (02)
  • [36] Panoramic Images versus Three-Dimensional Planning Software for Oral Implant Planning in Atrophied Posterior Maxillary: A Clinical Radiological Study
    Fortin, Thomas
    Camby, Elsa
    Alik, Mahdi
    Isidori, Michel
    Bouchet, Herve
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (02) : 198 - 204
  • [37] Incidence and outcomes of intraoperative periprosthetic acetabular fractures during cementless total hip arthroplasty: a prospective three-dimensional computer tomography-based study
    You-Seung Chun
    Hwan-Hee Lee
    Young-Wook Lim
    Yong-Sik Kim
    Soon-Yong Kwon
    Seung-Chan Kim
    International Orthopaedics, 2024, 48 : 667 - 674
  • [38] Incidence and outcomes of intraoperative periprosthetic acetabular fractures during cementless total hip arthroplasty: a prospective three-dimensional computer tomography-based study
    Chun, You-Seung
    Lee, Hwan-Hee
    Lim, Young-Wook
    Kim, Yong-Sik
    Kwon, Soon-Yong
    Kim, Seung-Chan
    INTERNATIONAL ORTHOPAEDICS, 2023, 48 (3) : 667 - 674
  • [39] Treatment of acetabular defects during revision total hip arthroplasty - preliminary clinical and radiological outcome using bone substitute materials
    Haenle, Maximilian
    Schlueter, Sybille
    Ellenrieder, Martin
    Mittelmeier, Wolfram
    Bader, Rainer
    HIP INTERNATIONAL, 2013, 23 (01) : 46 - 53
  • [40] Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis
    Kaku N.
    Tabata T.
    Tsumura H.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (8) : 1271 - 1277