The correlation between clinical radiological outcome and contact state of implant and femur using three-dimensional templating software in cementless total hip arthroplasty

被引:24
|
作者
Inoue D. [1 ]
Kabata T. [1 ]
Maeda T. [1 ]
Kajino Y. [1 ]
Yamamoto T. [1 ]
Takagi T. [1 ]
Ohmori T. [1 ]
Tsuchiya H. [1 ]
机构
[1] Department of Orthopaedic Surgery, Graduate School of Medical Science, Kanazawa University, 13-1 Takaramachi, Kanazawa, 920-8641, Ishikawa
基金
日本学术振兴会;
关键词
Density mapping; Radiological outcome; Three-dimensional templating software; Total hip arthroplasty;
D O I
10.1007/s00590-016-1796-5
中图分类号
学科分类号
摘要
Background: Initial fixation is a key factor in the success of cementless THA using a tapered wedge stem. The purpose of this study was to use three-dimensional templating software to examine the correlation between quantitative contact state and important clinical radiological outcomes, specifically stem subsidence, stress shielding, and cortical hypertrophy. Methods: We conducted a retrospective consecutive review of 75 hips in 70 patients over a minimum 3-year follow-up period. X-rays and CT scans were investigated to assess preoperative planning, quantify the contact state of implant and femur, and assess stem alignment, stem subsidence, stress shielding, and cortical hypertrophy. We evaluated the correlation between radiological outcomes and three-dimensional quantitative contact state according to Gruen Zone in each Dorr classification. Results: Density mapping indicated that stem subsidence increased postoperatively if the stem had less cortical contact in the middle to distal portion of the implant in terms of initial fixation. Cases having too much cortical contact in the distal portion of the implant tended to have increased stress shielding. We found no correlation between cortical hypertrophy and the contact state of implant and femur. Conclusions: Density mapping with three-dimensional templating software can be useful in predicting stem subsidence and stress shielding following cementless THA with a tapered wedge stem. Further analysis is required to accurately depict the correlation between cortical hypertrophy and the contact state. © 2016, Springer-Verlag France.
引用
收藏
页码:591 / 598
页数:7
相关论文
共 50 条
  • [21] Outcome of short- to medium-term migration analysis of a cementless short stem total hip arthroplasty using EBRA-FCA: a radiological and clinical study
    Alexander Jahnke
    Ann-Kathrin Wiesmair
    Carlos Alfonso Fonseca Ulloa
    Gafar Adam Ahmed
    Markus Rickert
    Bernd Alexander Ishaque
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 247 - 253
  • [22] Early clinical evaluation of total hip arthroplasty by three-dimensional gait analysis and muscle strength testing
    Gomi, Motosi
    Maezawa, Katsuhiko
    Nozawa, Masahiko
    Yuasa, Takahito
    Sugimoto, Munehiko
    Hayashi, Akito
    Mikawa, Saiko
    Kaneko, Kazuo
    GAIT & POSTURE, 2018, 66 : 214 - 220
  • [23] Preoperative CT-Based Three-Dimensional Templating in Robot-Assisted Total Knee Arthroplasty More Accurately Predicts Implant Sizes than Two-Dimensional Templating
    Pietrzak, J. R. T.
    Rowan, F. E.
    Kayani, B.
    Donaldson, M. J.
    Huq, S. S.
    Haddad, F. S.
    JOURNAL OF KNEE SURGERY, 2019, 32 (07) : 642 - 648
  • [24] Comparative Study for Postoperative Initial Fixation Patterns of Two Different Types of Cementless Short Stem Using Three-Dimensional Templating Software
    Nakai, Takuya
    Takeda, Yu
    Niitsu, Saori
    Fujihara, Yuki
    Okahisa, Shohei
    Tachibana, Toshiya
    Fukunishi, Shigeo
    CLINICS IN ORTHOPEDIC SURGERY, 2024, 16 (01) : 23 - 33
  • [25] Comparison between two- and three-dimensional methods for offset measurements after total hip arthroplasty
    Shine Tone
    Masahiro Hasegawa
    Yohei Naito
    Hiroki Wakabayashi
    Akihiro Sudo
    Scientific Reports, 12
  • [26] Comparison between two- and three-dimensional methods for offset measurements after total hip arthroplasty
    Tone, Shine
    Hasegawa, Masahiro
    Naito, Yohei
    Wakabayashi, Hiroki
    Sudo, Akihiro
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [27] Value of computed tomography-based three-dimensional surgical preoperative planning software in total hip arthroplasty with developmental dysplasia of the hip
    Inoue, Daisuke
    Kabata, Tamon
    Maeda, Toru
    Kajino, Yoshitomo
    Fujita, Kenji
    Hasegawa, Kazuhiro
    Yamamoto, Takashi
    Tsuchiya, Hiroyuki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2015, 20 (02) : 340 - 346
  • [28] Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography
    Bayraktar, Vahdettin
    Weber, Markus
    von Kunow, Frederik
    Zeman, Florian
    Craiovan, Benjamin
    Renkawitz, Tobias
    Grifka, Joachim
    Woerner, Michael
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (04) : 731 - 738
  • [29] Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography
    Vahdettin Bayraktar
    Markus Weber
    Frederik von Kunow
    Florian Zeman
    Benjamin Craiovan
    Tobias Renkawitz
    Joachim Grifka
    Michael Woerner
    International Orthopaedics, 2017, 41 : 731 - 738
  • [30] Femoral revision in total hip arthroplasty using a cementless modular stem: clinical and radiological results with a 8-year follow-up
    Spranz, David
    Skrobek, David
    Randoll, Jannis
    Kinkel, Stefan
    Merle, Christian
    Walker, Tilman
    Renkawitz, Tobias
    Reiner, Tobias
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (03) : 1369 - 1377