The correlation between clinical radiological outcome and contact state of implant and femur using three-dimensional templating software in cementless total hip arthroplasty

被引:24
|
作者
Inoue D. [1 ]
Kabata T. [1 ]
Maeda T. [1 ]
Kajino Y. [1 ]
Yamamoto T. [1 ]
Takagi T. [1 ]
Ohmori T. [1 ]
Tsuchiya H. [1 ]
机构
[1] Department of Orthopaedic Surgery, Graduate School of Medical Science, Kanazawa University, 13-1 Takaramachi, Kanazawa, 920-8641, Ishikawa
基金
日本学术振兴会;
关键词
Density mapping; Radiological outcome; Three-dimensional templating software; Total hip arthroplasty;
D O I
10.1007/s00590-016-1796-5
中图分类号
学科分类号
摘要
Background: Initial fixation is a key factor in the success of cementless THA using a tapered wedge stem. The purpose of this study was to use three-dimensional templating software to examine the correlation between quantitative contact state and important clinical radiological outcomes, specifically stem subsidence, stress shielding, and cortical hypertrophy. Methods: We conducted a retrospective consecutive review of 75 hips in 70 patients over a minimum 3-year follow-up period. X-rays and CT scans were investigated to assess preoperative planning, quantify the contact state of implant and femur, and assess stem alignment, stem subsidence, stress shielding, and cortical hypertrophy. We evaluated the correlation between radiological outcomes and three-dimensional quantitative contact state according to Gruen Zone in each Dorr classification. Results: Density mapping indicated that stem subsidence increased postoperatively if the stem had less cortical contact in the middle to distal portion of the implant in terms of initial fixation. Cases having too much cortical contact in the distal portion of the implant tended to have increased stress shielding. We found no correlation between cortical hypertrophy and the contact state of implant and femur. Conclusions: Density mapping with three-dimensional templating software can be useful in predicting stem subsidence and stress shielding following cementless THA with a tapered wedge stem. Further analysis is required to accurately depict the correlation between cortical hypertrophy and the contact state. © 2016, Springer-Verlag France.
引用
收藏
页码:591 / 598
页数:7
相关论文
共 50 条
  • [1] Usefullness of three-dimensional templating software to quantify the contact state between implant and femur in total hip arthroplasty
    Inoue D.
    Kabata T.
    Maeda T.
    Kajino Y.
    Fujita K.
    Hasegawa K.
    Yamamoto T.
    Takagi T.
    Ohmori T.
    Tsuchiya H.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (8) : 1293 - 1300
  • [2] Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty
    Wada, Hiroshi
    Mishima, Hajime
    Sugaya, Hisashi
    Nishino, Tomofumi
    Yamazaki, Masashi
    ADVANCES IN ORTHOPEDICS, 2016, 2016
  • [3] Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating
    Sariali, E.
    Mauprivez, R.
    Khiami, F.
    Pascal-Mousselard, H.
    Catonne, Y.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (02) : 151 - 158
  • [4] Three-Dimensional Templating for Acetabular Component Alignment During Total Hip Arthroplasty
    Elbuluk, Ameer M.
    Wojack, Paul
    Eftekhary, Nima
    Vigdorchik, Jonanathan M.
    ORTHOPEDICS, 2017, 40 (04) : E708 - E713
  • [5] Comparisons of Preoperative Three-Dimensional Planning and Surgical Reconstruction in Primary Cementless Total Hip Arthroplasty
    Hassani, Hassen
    Cherix, Stephane
    Ek, Eugene T.
    Ruediger, Hannes A.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (06): : 1273 - 1277
  • [6] Clinical and radiological outcomes in three-dimensional printing assisted revision total hip and knee arthroplasty: a systematic review
    Rui Zhang
    Jiajun Lin
    Fenyong Chen
    Wenge Liu
    Min Chen
    Journal of Orthopaedic Surgery and Research, 16
  • [7] Clinical and radiological outcomes in three-dimensional printing assisted revision total hip and knee arthroplasty: a systematic review
    Zhang, Rui
    Lin, Jiajun
    Chen, Fenyong
    Liu, Wenge
    Chen, Min
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [8] Interobserver and Intraobserver Reliabilities of Three-Dimensional Postoperative Evaluation Software in Total Hip Arthroplasty
    Konno, Kenta
    Hagiwara, Shigeo
    Nakamura, Junichi
    Kawarai, Yuya
    Orita, Sumihisa
    Eguchi, Yawara
    Ohtori, Seiji
    ADVANCES IN ORTHOPEDICS, 2021, 2021
  • [9] A NEW VISUAL SOFTWARE TOOL FOR THREE-DIMENSIONAL MOTION ANALYSES IN TOTAL HIP ARTHROPLASTY
    Wei, Shan
    Xu, Chengtao
    Zhang, Rengang
    Wang, Zhengyu
    Yang, Min
    Zhang, Yong
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2023, 19 : 9 - 10
  • [10] Interobserver and Intraobserver Reliability of Three-Dimensional Preoperative Planning Software in Total Hip Arthroplasty
    Wako, Yasushi
    Nakamura, Junichi
    Miura, Michiaki
    Kawarai, Yuya
    Sugano, Masahiko
    Nawata, Kento
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02): : 601 - 607