Accuracy of pulse oximetry in the intensive care unit

被引:0
|
作者
A. Louw
C. Cracco
C. Cerf
A. Harf
P. Duvaldestin
F. Lemaire
L. Brochard
机构
[1] Anesthesiology Department and Surgical Intensive Care Unit,
[2] Henri Mondor Hospital,undefined
[3] Assistance Publique-Hôpitaux de Paris,undefined
[4] University Paris XII,undefined
[5] Créteil,undefined
[6] France,undefined
[7] Medical Intensive Care Unit,undefined
[8] Henri Mondor Hospital,undefined
[9] Assistance Publique-Hôpitaux de Paris,undefined
[10] University Paris XII,undefined
[11] Créteil,undefined
[12] France,undefined
[13] Physiology Department,undefined
[14] Henri Mondor Hospital,undefined
[15] Assistance Publique-Hôpitaux de Paris,undefined
[16] University Paris XII,undefined
[17] Créteil,undefined
[18] France,undefined
来源
Intensive Care Medicine | 2001年 / 27卷
关键词
Pulse oximetry Monitoring Oxygen saturation Intensive care;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: Pulse oximetry (SpO2) is a standard monitoring device in intensive care units (ICUs), currently used to guide therapeutic interventions. Few studies have evaluated the accuracy of SpO2 in critically ill patients. Our objective was to compare pulse oximetry with arterial oxygen saturation (SaO2) in such patients, and to examine the effect of several factors on this relationship. Design: Observational prospective study. Setting: A 26-bed medical ICU in a university hospital. Patients: One hundred two consecutive patients admitted to the ICU in whom one or serial arterial blood gas analyses (ABGs) were performed and a reliable pulse oximeter signal was present. Interventions: For each ABG, we collected SaO2, SpO2, the type of pulse oximeter, the mode of ventilation and requirement for vasoactive drugs. Measurements and results: Three hundred twenty-three data points were collected. The mean difference between SpO2 and SaO2 was –0.02% and standard deviation of the differences was 2.1%. From one sample to another, the fluctuations in SpO2 to arterial saturation difference indicated that SaO2 could not be reliably predicted from SpO2 after a single ABG. Subgroup analysis showed that the accuracy of SpO2 appeared to be influenced by the type of oximeter, the presence of hypoxemia and the requirement for vasoactive drugs. Finally, high SpO2 thresholds were necessary to detect significant hypoxemia with good sensitivity. Conclusion: Large SpO2 to SaO2 differences may occur in critically ill patients with poor reproducibility of SpO2. A SpO2 above 94% appears necessary to ensure a SaO2 of 90%.
引用
收藏
页码:1606 / 1613
页数:7
相关论文
共 50 条
  • [1] Accuracy of pulse oximetry in the intensive care unit
    Van de Louw, A
    Cracco, C
    Cerf, C
    Harf, A
    Duvaldestin, P
    Lemaire, F
    Brochard, L
    INTENSIVE CARE MEDICINE, 2001, 27 (10) : 1606 - 1613
  • [2] Accuracy and precision of pulse oximetry in ventilated patients of an intensive care unit
    Hinkelbein, J.
    Osika, A.
    Fiedler, F.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 179 - 179
  • [3] Evidence for the need of bedside accuracy of pulse oximetry in an intensive care unit
    Seguin, P
    Le Rouzo, A
    Tanguy, M
    Guillou, YM
    Feuillu, A
    Mallédant, Y
    CRITICAL CARE MEDICINE, 2000, 28 (03) : 703 - 706
  • [4] Accuracy of pulse oximetry in assessing heart rate of infants in the neonatal intensive care unit
    Singh, Jasbir K. S. B.
    Kamlin, C. Omar F.
    Morley, Colin J.
    O'Donnell, Colm P. F.
    Donath, Susan M.
    Davis, Peter G.
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2008, 44 (05) : 273 - 275
  • [5] THE USE OF PULSE OXIMETRY IN THE NEWBORN INTENSIVE-CARE UNIT
    WISWELL, TE
    HANKINS, CT
    PEDIATRIC RESEARCH, 1987, 21 (04) : A470 - A470
  • [6] Accuracy of continuous jugular bulb oximetry in the intensive care unit
    Coplin, WM
    O'Keefe, GE
    Grady, MS
    Grant, GA
    March, KS
    Winn, HR
    Lam, AM
    NEUROSURGERY, 1998, 42 (03) : 533 - 539
  • [7] Transesophageal versus surface pulse oximetry in intensive care unit patients
    Vicenzi, MN
    Gombotz, H
    Krenn, H
    Dorn, C
    Rehak, P
    CRITICAL CARE MEDICINE, 2000, 28 (07) : 2268 - 2270
  • [8] Accuracy of continuous jugular bulb oximetry in the intensive care unit - Comment
    Narayan, RK
    NEUROSURGERY, 1998, 42 (03) : 539 - 539
  • [9] Rethinking Pulse Oximetry Screening in the Level IV Neonatal Intensive Care Unit
    Schwartz, Bryanna N.
    Hom, Lisa A.
    Revenis, Mary E.
    Martin, Gerard R.
    AMERICAN JOURNAL OF PERINATOLOGY, 2022, 39 : S49 - S51
  • [10] EFFECT OF PULSE OXIMETRY ON CLINICAL-PRACTICE IN THE INTENSIVE-CARE UNIT
    SOLSONA, JF
    MARRUGAT, J
    VAZQUEZ, A
    MASDEU, G
    ALVAREZ, F
    NOLLA, J
    LANCET, 1993, 342 (8866): : 311 - 312