Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study

被引:0
|
作者
David Campbell
Graham Mercer
Kjell G. Nilsson
Vanessa Wells
John R. Field
Stuart A. Callary
机构
[1] Repatriation General Hospital,Orthopaedic Unit
[2] Umeå University Hospital,Department of Orthopaedics
[3] Flinders University,CORe: Comparative Orthopaedic Research Surgical Facility
[4] University of Adelaide,Discipline of Orthopaedics and Trauma
[5] Royal Adelaide Hospital,Department of Orthopaedics and Trauma
来源
关键词
Stem Rotation; Early Migration; Stem Subsidence; Cementless Stem; Radiostereometric Analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Measurement of early stem subsidence can be used to predict the likelihood of long-term femoral component loosening and clinical failure. Data that examines the early migration pattern of clinically proven stems will provide clinicians with useful baseline data with which to compare new stem designs. This study was performed to evaluate the early migration pattern of a hydroxyapatite-coated press-fit femoral component that has been in use for over ten years. We enrolled 30 patients who underwent THA for osteoarthritis. The median age was 70 years (range, 55–80 years). Patients were clinically assessed using the Harris hip score. Radiostereometric analysis was used to evaluate stem migration at three to four days, six months, one year and two years. We observed a mean subsidence of 0.73 mm at six months, 0.62 mm at one year and 0.58 mm at two years and a mean retroversion of 1.82° at six months, 1.90° at one year and 1.59° at two years. This data suggests that subsidence is confined to the first six months after which there was no further subsidence. The results from this study can be compared with those from novel cementless stem designs to help predict the long-term outcome one may expect from new cementless stem designs.
引用
收藏
页码:483 / 488
页数:5
相关论文
共 50 条
  • [1] Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study
    Campbell, David
    Mercer, Graham
    Nilsson, Kjell G.
    Wells, Vanessa
    Field, John R.
    Callary, Stuart A.
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (04) : 483 - 488
  • [2] The 6-Year Migration Characteristics of a Hydroxyapatite-Coated Femoral Stem A Radiostereometric Analysis Study
    Callary, Stuart A.
    Campbell, David G.
    Mercer, Graham E.
    Nilsson, Kjell G.
    Field, John R.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (07): : 1344 - 1348
  • [3] Migration characteristics of the Corail hydroxyapatite-coated femoral stem—a retrospective clinical evaluation and migration measurement with EBRA
    Dietmar Dammerer
    Philipp Blum
    David Putzer
    Dietmar Krappinger
    Christof Pabinger
    Michael C. Liebensteiner
    Martin Thaler
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 517 - 524
  • [4] MIGRATION OF HYDROXYAPATITE-COATED FEMORAL PROSTHESES - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY
    SOBALLE, K
    TOKSVIGLARSEN, S
    GELINECK, J
    FRUENSGAARD, S
    HANSEN, ES
    RYD, L
    LUCHT, U
    BUNGER, C
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (05): : 681 - 687
  • [5] Migration characteristics of the Corail hydroxyapatite-coated femoral stem-a retrospective clinical evaluation and migration measurement with EBRA
    Dammerer, Dietmar
    Blum, Philipp
    Putzer, David
    Krappinger, Dietmar
    Pabinger, Christof
    Liebensteiner, Michael C.
    Thaler, Martin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (03) : 517 - 524
  • [6] Hydroxyapatite-coated femoral stem survivorship at 10 years
    Lee, GY
    Srivastava, A
    D'Lima, DD
    Pulido, P
    Colwell, CW
    BIOCERAMICS 17, 2005, 284-286 : 1069 - 1072
  • [7] Hydroxyapatite-coated femoral stem survivorship at 10 years
    Lee, GY
    Srivastava, A
    D'Lima, DD
    Pulido, PA
    Colwell, CW
    JOURNAL OF ARTHROPLASTY, 2005, 20 (07): : 57 - 62
  • [8] The effect of intramedullary bone plug on femoral stem migration of hydroxyapatite-coated hip arthroplasty
    Kligman, M
    Roffman, M
    ORTHOPEDICS, 2000, 23 (07) : 681 - 685
  • [9] Femoral revision using long hydroxyapatite-coated interlocking stem
    Malhotra, R.
    Dua, Aman
    Kiran, E. Krishna
    Bhan, S.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (04) : 355 - 362
  • [10] Femoral revision using long hydroxyapatite-coated interlocking stem
    R. Malhotra
    Aman Dua
    E. Krishna Kiran
    S. Bhan
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 355 - 362