Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom

被引:0
|
作者
S. Kaddouch
N. El Khayati
机构
[1] Mohammed V University,ESMaR, Faculty of Science
来源
关键词
internal dosimetry; Geant4/GATE; voxelized phantoms; specific absorbed fraction;
D O I
暂无
中图分类号
学科分类号
摘要
It is of great interest to estimate absorbed doses in organs before radiation therapy, especially in nuclear medicine field. In this regard, the internal dose distribution is required. According to the MIRD formalism, Specific Absorbed Fraction (SAF) is an essential parameter for internal dosimetry. In the present work, SAF values for the voxelized phantom (Golem) of the GSF-National Research Center for Environment and Health were calculated using Geant4/GATE with Standard packages and compared with GSF Monte Carlo reference data. Photon irradiations of 30, 100 keV and 1 MeV energy were simulated in eleven different sources and target organs: liver, kidneys, lungs, brain, pancreas, spleen, colon, Red bone marrow (RBM), stomach, thyroid and adrenals. The SAF for self-absorption and for cross-irradiation to other organs were calculated and compared with literature. The results agree with published data, with an average relative difference less than 3%, for the self-absorption of 100 keV and 1 MeV photon energies. The agreement of Geant4/GATE and GSF code might depend on the distance between target and source, the target mass and the photons energy. Generally, the present results indicate that GATE might be used with gamma emitters for internal dosimetry in regard to our prospective works.
引用
收藏
页码:658 / 662
页数:4
相关论文
共 50 条
  • [31] TOUCANS: A versatile Monte Carlo neutron transport code based on GEANT4
    Thulliez, L.
    Mom, B.
    Dumonteil, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1051
  • [32] Consistency test of the electron transport algorithm in the GEANT4 Monte Carlo code
    Poon, E
    Seuntjens, J
    Verhaegen, F
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (04): : 681 - 694
  • [33] Validation of Monte Carlo Geant4 code for a 6 MV Varian linac
    EL Bakkali, Jaafar
    EL Bardouni, Tarek
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2017, 29 (01) : 106 - 113
  • [34] Monte Carlo simulation of the ELIMED beamline using Geant4
    Pipek, J.
    Romano, F.
    Milluzzo, G.
    Cirrone, G. A. P.
    Cuttone, G.
    Amico, A. G.
    Margarone, D.
    Larosa, G.
    Leanza, R.
    Petringa, G.
    Schillaci, F.
    Scuderi, V.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [35] Monte Carlo Simulation of a 18 MV Medical Linac Photon Beam Using GATE/GEANT4
    M. Fiak
    A. Fathi
    J. Inchaouh
    A. Khouaja
    A. Benider
    M. Krim
    N. Harakat
    Z. Housni
    M. L. Bouhssa
    M. Mouadil
    Y. Elabssaoui
    O. Jdair
    Moscow University Physics Bulletin, 2021, 76 : 15 - 21
  • [36] Application of GATE/Geant4 for internal dosimetry using male ICRP reference voxel phantom by specific absorbed fractions calculations for photon irradiation
    Costa, G. C. A.
    de Sa, L. V.
    Bonifacio, D. A. B.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (04):
  • [37] Monte Carlo Simulation of a 18 MV Medical Linac Photon Beam Using GATE/GEANT4
    Fiak, M.
    Fathi, A.
    Inchaouh, J.
    Khouaja, A.
    Benider, A.
    Krim, M.
    Harakat, N.
    Housni, Z.
    Bouhssa, M. L.
    Mouadil, M.
    Elabssaoui, Y.
    Jdair, O.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (01) : 15 - 21
  • [38] Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
    Padilla-Cabal, Fatima
    Alejandro Fragoso, Jose
    Resch, Andreas Franz
    Georg, Dietmar
    Fuchs, Hermann
    MEDICAL PHYSICS, 2020, 47 (01) : 223 - 233
  • [39] Erratum to: Simulation of Electron Trajectories in the Multicusp Ion Source Using Geant4 Monte Carlo Code
    Fatemeh Khodadadi Azadboni
    Mahmood Sedaghatizade
    Journal of Fusion Energy, 2010, 29 : 305 - 305
  • [40] Validation of Monte Carlo code GATE on the ICRP/ICRU female reference computational phantom for internal dosimetry aspects.
    Villoing, D.
    Mauxion, T.
    Marcatili, S.
    Poirot, M.
    Bardies, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S161 - S161