A re-assessment of nickel-doping method in iron isotope analysis on rock samples using multi-collector inductively coupled plasma mass spectrometry

被引:0
|
作者
Hongmei Gong
Pengyuan Guo
Shuo Chen
Meng Duan
Pu Sun
Xiaohong Wang
Yaoling Niu
机构
[1] Institute of Oceanology,Key Laboratory of Marine Geology and Environment
[2] Chinese Academy of Sciences,Department of Earth Sciences
[3] Qingdao National Laboratory for Marine Science and Technology,School of Earth Science and Resources
[4] Durham University,undefined
[5] China University of Geosciences,undefined
[6] Institute of Oceanology,undefined
[7] Chinese Academy of Sciences,undefined
来源
Acta Geochimica | 2020年 / 39卷
关键词
Fe isotope; Ni-doping; Stable isotope; Precision and accuracy; Mass bias correction; Pseudo-high mass resolution;
D O I
暂无
中图分类号
学科分类号
摘要
Element doping has been proved to be a useful method to correct for the mass bias fractionation when analyzing iron isotope compositions. We present a systematic re-assessment on how the doped nickel may affect the iron isotope analysis in this study by carrying out several experiments. We find three important factors that can affect the analytical results, including the Ni:Fe ratio in the analyte solutions, the match of the Ni:Fe ratio between the unknown sample and standard solutions, and the match of the Fe concentration between the sample and standard solutions. Thus, caution is required when adding Ni to the analyte Fe solutions before analysis. Using our method, the δ56Fe and δ57Fe values of the USGS standards W-2a, BHVO-2, BCR-2, AGV-2 and GSP-2 are consistent with the recommended literature values, and the long-term (one year) external reproducibility is better than 0.03 and 0.05‰ (2SD) for δ56Fe and δ57Fe, respectively. Therefore, the analytical method established in our laboratory is a method of choice for high quantity Fe isotope data in geological materials.
引用
收藏
页码:355 / 364
页数:9
相关论文
共 50 条
  • [41] Precise analysis of potassium isotopic composition in plant materials by multi-collector inductively coupled plasma mass spectrometry
    He, Mao-Yong
    Ren, Tong Xiang
    Jin, Zhang Dong
    Deng, Li
    Liu, Hai Jiao
    Cheng, Yuan Yuan
    Li, Zheng Yan
    Liu, Xing Xing
    Yang, Yang
    Chang, Hong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2023, 209
  • [42] Adapting automated instrumentation for high-throughput calcium isotope measurements by multi-collector inductively coupled plasma mass spectrometry
    Razionale, Dan
    Bryant, Roger N.
    Blattler, Clara L.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2022, 36 (07)
  • [43] Fit for purpose validated method for the determination of the strontium isotopic signature in mineral water samples by multi-collector inductively coupled plasma mass spectrometry
    Brach-Papa, Christophe
    Van Bocxstaele, Marleen
    Ponzevera, Emmanuel
    Quetel, Christophe R.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (03) : 229 - 234
  • [44] An isotopic perspective on mass bias and matrix effects in multi-collector inductively-coupled-plasma mass spectrometry
    Barling, Jane
    Weis, Dominique
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (04) : 653 - 662
  • [45] Modified ion exchange separation for tungsten isotopic measurements from kimberlite samples using multi-collector inductively coupled plasma mass spectrometry
    Sahoo, YV
    Nakai, S
    Ali, A
    ANALYST, 2006, 131 (03) : 434 - 439
  • [46] Assessment of matrix effects associated with Fe isotope analysis using 266 nm femtosecond and 193 nm nanosecond laser ablation multi-collector inductively coupled plasma mass spectrometry
    Zheng, Xin-Yuan
    Beard, Brian L.
    Johnson, Clark M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (01) : 68 - 83
  • [47] Revised exponential model for mass bias correction using an internal standard for isotope abundance ratio measurements by multi-collector inductively coupled plasma mass spectrometry
    Baxter, DC
    Rodushkin, I
    Engström, E
    Malinovsky, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (04) : 427 - 430
  • [48] Recent advances in the analysis of non-traditional stable isotopes by multi-collector inductively coupled plasma mass spectrometry
    Lu, Dawei
    Zhang, Tuoya
    Yang, Xuezhi
    Su, Peng
    Liu, Qian
    Jiang, Guibin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (10) : 1848 - 1861
  • [49] Accurate lithium isotopic analysis of twenty geological reference materials by multi-collector inductively coupled plasma mass spectrometry
    Li, Xiaoqiang
    Han, Guilin
    Zhang, Qian
    Qu, Rui
    Miao, Zhuang
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 188