An Amperometric Glucose Biosensor Based on Titania Sol-gel/Prussian Blue Composite Film

被引:0
|
作者
Ruping Liang
Jingli Jiang
Jianding Qiu
机构
[1] Nanchang University,Department of Chemistry
来源
Analytical Sciences | 2008年 / 24卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
An improved amperometric glucose biosensor was constructed by immobilizing glucose oxidase (GOD) in a titania sol-gel film, which was prepared by a vapor deposition method, on a Prussian Blue (PB)-modified electrode. The method combined the merits of immobilizing biomolecules in the titania sol-gel film by vapor deposition method and the synergic catalysis effects of PB and GOD molecules. Results showed that the fabricated titania sol-gel/PB membrane possessed high surface area, good mechanical stability, and good hydrophilicity, which provided a biocompatible microenvironment for maintaining the bioactivity of the immobilized enzyme and prevented the enzyme from leaking out of the film. Therefore, the present biosensor exhibited fast response time (10 s), high sensitivity (12.74 µA cm–2 mM–1), long-term operational stability, good suppression of interference, and a wide linear range from 0.02 to 15 mM with a low detection limit of 5 mM for the detection of glucose. In addition, this simple and controllable method could fabricate biosensors in batches with a very small amount of enzyme.
引用
收藏
页码:1425 / 1430
页数:5
相关论文
共 50 条
  • [31] Renewable silica sol-gel derived carbon composite based glucose biosensor
    Li, J
    Chia, LS
    Goh, NK
    Tan, SN
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 460 (1-2): : 234 - 241
  • [32] Glucose biosensor based on PEM films/sol-gel matrix composite membrane
    Xu, Xinhua
    Feng, Wei, Sr.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233
  • [33] A glucose biosensor based on Prussian blue/chitosan hybrid film
    Wang, Xueying
    Gu, Haifang
    Yin, Fan
    Tu, Yifeng
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (05): : 1527 - 1530
  • [34] A TiO2-Sol-Gel derived Prussian blue nanoparticles-based glucose biosensor
    Li, Jianping
    Wang, Sufen
    Ayoub, Iyad M.
    Yang, Catherine F.
    [J]. 2007 IEEE SENSORS APPLICATIONS SYMPOSIUM, 2007, : 63 - +
  • [35] A highly-sensitive glucose biosensor based on Prussian Blue modified electrode combined with SiO2 sol-gel immobilization
    Li, T
    Yao, ZH
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (02) : 237 - 240
  • [36] Amperometric glucose biosensor based on Prussian blue-multiwall carbon nanotubes composite and hollow PtCo nanochains
    Che, Xin
    Yuan, Ruo
    Chai, Yaqin
    Li, Jingjing
    Song, Zhongju
    Li, Wenjuan
    [J]. ELECTROCHIMICA ACTA, 2010, 55 (19) : 5420 - 5427
  • [37] Sol-gel coated prussian blue modified electrode for electrocatalytic oxidation and amperometric determination of thiols
    Deepa, PN
    Narayanan, SS
    [J]. BULLETIN OF ELECTROCHEMISTRY, 2001, 17 (06): : 259 - 264
  • [38] The Development of Reagentless Amperometric Glucose Biosensor Based on Gold Nanostructures, Prussian Blue and Glucose Oxidase
    Sakalauskiene, Laura
    Brasiunas, Benediktas
    Popov, Anton
    Kausaite-Minkstimiene, Asta
    Ramanaviciene, Almira
    [J]. BIOSENSORS-BASEL, 2023, 13 (10):
  • [39] Amperometric biosensor based on monoamine oxidase (MAO) immobilized in sol-gel film for benzydamine determination in pharmaceuticals
    de Jesus, DS
    Couto, CMCM
    Araújo, AN
    Montenegro, MCBSM
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (05) : 983 - 990
  • [40] Al2O3 sol-gel derived amperometric biosensor for glucose
    Liu, ZJ
    Liu, BH
    Zhang, M
    Kong, JL
    Deng, JQ
    [J]. ANALYTICA CHIMICA ACTA, 1999, 392 (2-3) : 135 - 141