Development and Validation of a High-Performance Liquid Chromatography Method for the Determination of Histamine in Fish Samples Using Fluorescence Detection with Pre-column Derivatization

被引:1
|
作者
Ayoub Kounnoun
Mohamed EL Maadoudi
Francesco Cacciola
Luigi Mondello
Hajar Bougtaib
Naoual Alahlah
Nadia Amajoud
Aicha EL Baaboua
Adnane Louajri
机构
[1] Abd Al Malek Essaadi University,Laboratory of Applied Biology and Pathology, Department of Biology, Faculty of Sciences of Tetouan
[2] National Office of Food Safety ONSSA,Regional Analysis and Research Laboratory
[3] University of Messina,Department of Biomedical, Dental, Morphological and Functional Imaging Sciences
[4] University of Messina,Department of Chemical Biological, Pharmaceutical and Environmental Sciences
[5] University of Messina,Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences
[6] University Campus Bio-Medico of Rome,Department of Sciences and Technologies for Human and Environment
[7] University of Messina,BeSep s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences
来源
Chromatographia | 2020年 / 83卷
关键词
Histamine; Fish; HPLC-FLD; Pre-column derivatization; Optimization; Validation;
D O I
暂无
中图分类号
学科分类号
摘要
Histamine level determination in fish and fish products is important for human safety, fish quality and food industry. For this reason, a rapid, robust, and precise method is needed. To achieve this objective, an HPLC method with fluorescence detection was developed and validated. Histamine in fish samples was efficiently extracted with perchloric acid, and purified with ion-exchange solid-phase extraction cartridge. A pre-column derivatization was adopted with ortho-phthalaldehyde (OPA) in the presence of the reducing agent 2-mercaptoethanol, and the stability of the histamine-OPA derivatives was achieved with the acidification of the reaction medium. In terms of validation, besides the excellent linear correlations, satisfactory recoveries at all spiking levels ranging between 0 and 200 mg kg−1 were attained, with limit of detection calculated at 1.8 mg kg−1, whereas limit of quantification determined at 5 mg kg−1. The proposed method was successfully used in the analysis of reference materials and proficiency tests, and was found to be suitable, accurate, and rapid for detection and quantification of histamine in various fish samples.
引用
收藏
页码:893 / 901
页数:8
相关论文
共 50 条
  • [41] Quantification of cyclamate and cyclohexylamine in urine samples using high-performance liquid chromatography with trinitrobenzenesulfonic acid pre-column derivatization
    Casals, I
    Reixach, M
    Amat, J
    Fuentes, M
    SerraMajem, L
    JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) : 397 - 402
  • [42] High-performance liquid chromatography method validation for the quantification of tobramycin in urine samples after inhalation using pre-column derivatization with fluorescent 9-fluorenylmethylchloroformate
    Mashat, M.
    Clark, B. J.
    Chystyn, H.
    Assi, K. H.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2008, 60 : A48 - A48
  • [43] Pre-column derivatization-high performance liquid chromatography for the determination of aliphatic amines with fluorescence detection and mass spectrometric identification
    Zhao Xian-En
    Li Yu-Lin
    You Jin-Mao
    Liu Yong-Jun
    Suo You-Rui
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (06) : 779 - 785
  • [44] RAPID AND SENSITIVE METHOD FOR THE DETERMINATION OF PROLINE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AUTOMATED PRE-COLUMN FLUORESCENCE DERIVATIZATION
    CARISANO, A
    JOURNAL OF CHROMATOGRAPHY, 1985, 318 (01): : 132 - 138
  • [45] Determination of netilmicin in rat plasma by reversed-phase high performance liquid chromatography with fluorescence detection and pre-column derivatization
    Chang Xiaojuan
    Peng Jingdong
    Liu Shaopu
    Liu Limin
    Dai Yongkuang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (06) : 794 - 798
  • [46] Determination of kanamycin A in animal feeds by solid phase extraction and high performance liquid chromatography with pre-column derivatization and fluorescence detection
    Zhou, Y. X.
    Yang, W. J.
    Zhang, L. Y.
    Wang, Z. Y.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (9-12) : 1603 - 1615
  • [47] Highly sensitive and selective determination of 9,10-phenanthrenequinone in airborne particulates using high-performance liquid chromatography with pre-column derivatization and fluorescence detection
    Kishikawa, N
    Wada, M
    Ohba, Y
    Nakashima, K
    Kuroda, N
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1057 (1-2) : 83 - 88
  • [48] Determination of Erythromycylamine in Human Serum by High Performance Liquid Chromatography with Pre-column Derivatization
    Wei Min-Ji
    Zhao Cai-Yun
    Lue Yuan
    Zhang Pu
    Zhang Ming
    Liu Yan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (06) : 907 - 910
  • [49] Determination of biogenic amines in beer with pre-column derivatization by high performance liquid chromatography
    Tang, Tao
    Shi, Tianyu
    Qian, Kun
    Li, Pingliang
    Li, Jianqiang
    Cao, Yongsong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (5-6): : 507 - 512
  • [50] Development and validation of an analytical method for the determination of histamine in wines using high performance liquid chromatography with fluorescence detection
    Prestes, Osmar D.
    Presta, Michele A.
    Kolberg, Diana I. S.
    Zanella, Renato
    Rossato, Simone B.
    Penna, Neidi G.
    Hecktheuer, Luisa H. R.
    QUIMICA NOVA, 2007, 30 (01): : 18 - 21