Development and Validation of a High-Performance Liquid Chromatography Method for the Determination of Histamine in Fish Samples Using Fluorescence Detection with Pre-column Derivatization

被引:1
|
作者
Ayoub Kounnoun
Mohamed EL Maadoudi
Francesco Cacciola
Luigi Mondello
Hajar Bougtaib
Naoual Alahlah
Nadia Amajoud
Aicha EL Baaboua
Adnane Louajri
机构
[1] Abd Al Malek Essaadi University,Laboratory of Applied Biology and Pathology, Department of Biology, Faculty of Sciences of Tetouan
[2] National Office of Food Safety ONSSA,Regional Analysis and Research Laboratory
[3] University of Messina,Department of Biomedical, Dental, Morphological and Functional Imaging Sciences
[4] University of Messina,Department of Chemical Biological, Pharmaceutical and Environmental Sciences
[5] University of Messina,Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences
[6] University Campus Bio-Medico of Rome,Department of Sciences and Technologies for Human and Environment
[7] University of Messina,BeSep s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences
来源
Chromatographia | 2020年 / 83卷
关键词
Histamine; Fish; HPLC-FLD; Pre-column derivatization; Optimization; Validation;
D O I
暂无
中图分类号
学科分类号
摘要
Histamine level determination in fish and fish products is important for human safety, fish quality and food industry. For this reason, a rapid, robust, and precise method is needed. To achieve this objective, an HPLC method with fluorescence detection was developed and validated. Histamine in fish samples was efficiently extracted with perchloric acid, and purified with ion-exchange solid-phase extraction cartridge. A pre-column derivatization was adopted with ortho-phthalaldehyde (OPA) in the presence of the reducing agent 2-mercaptoethanol, and the stability of the histamine-OPA derivatives was achieved with the acidification of the reaction medium. In terms of validation, besides the excellent linear correlations, satisfactory recoveries at all spiking levels ranging between 0 and 200 mg kg−1 were attained, with limit of detection calculated at 1.8 mg kg−1, whereas limit of quantification determined at 5 mg kg−1. The proposed method was successfully used in the analysis of reference materials and proficiency tests, and was found to be suitable, accurate, and rapid for detection and quantification of histamine in various fish samples.
引用
收藏
页码:893 / 901
页数:8
相关论文
共 50 条
  • [31] Fluorescence determination of N-acetylaspartic acid in the rat cerebrum homogenate using high-performance liquid chromatography with pre-column fluorescence derivatization
    Fukushima, Takeshi
    Arai, Kotaro
    Tomiya, Masayuki
    Mitsuhashi, Shogo
    Sasaki, Tsukasa
    Santa, Tomofumi
    Imai, Kazuhiro
    Toyo'oka, Toshimasa
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (01) : 100 - 105
  • [32] Determination of clarithromycin in serum by high performance liquid chromatography with pre-column derivatization
    Wei Minji
    Lu Yuan
    Wang Shan
    Zhang Pu
    Liu Yan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 : S168 - S170
  • [34] Determination of N,N-dimethyldithiocarbamate in wastewater using pre-column derivatization and high-performance liquid chromatography
    Cao, Xianzhong
    Li, Yongmei
    ANALYTICAL METHODS, 2012, 4 (09) : 2996 - 3001
  • [35] DETERMINATION OF THE COMPONENT RATIO OF COMMERCIAL GENTAMICINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING PRE-COLUMN DERIVATIZATION
    CLAES, PJ
    BUSSON, R
    VANDERHAEGHE, H
    JOURNAL OF CHROMATOGRAPHY, 1984, 298 (03): : 445 - 457
  • [36] Analysis of peptides and amino acids by pre-column derivatization high performance liquid chromatography with fluorescence detection
    Liu, X
    Xu, GL
    Zhang, HS
    Cheng, JK
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1997, 18 (06): : 873 - 876
  • [37] Determination of neurotransmitters in rat telencephalon using pre-column fluorescence derivatization with high performance liquid chromatography/mass spectrometry
    Zhao Xian-En
    Suo You-Rui
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (01) : 12 - 18
  • [38] USE OF BENZOIN AS PRE-COLUMN FLUORESCENCE DERIVATIZATION REAGENT FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF ANGIOTENSINS
    KAI, M
    MIYAZAKI, T
    SAKAMOTO, Y
    OHKURA, Y
    JOURNAL OF CHROMATOGRAPHY, 1985, 322 (03): : 473 - 477
  • [39] Liquid chromatography with fluorescence detection of amoxicillin and ampicillin in feeds using pre-column derivatization
    Gamba, V
    Dusi, G
    ANALYTICA CHIMICA ACTA, 2003, 483 (1-2) : 69 - 72
  • [40] Synthesis of Fluorescent Coumarin Derivatization Reagent and Development of a Pre-column Derivatization-High Performance Liquid Chromatography with Fluoresence Detection Method for Fipronil Determination
    Liu, Yuan
    Liu, Jia
    Tang, Daobang
    Tu, Yonggang
    Zang, Jianwei
    Wu, Yuqing
    Chen, Jiguang
    Zhang, Qingfeng
    Yin, Zhongping
    Shipin Kexue/Food Science, 2022, 43 (20): : 343 - 351