Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)

被引:0
|
作者
Holger Greess
Anton Nömayr
Heiko Wolf
Ulrich Baum
Michael Lell
Bernhard Böwing
Willi Kalender
Werner A. Bautz
机构
[1] Institute of Diagnostic Radiology,
[2] Friedrich Alexander University Erlangen–Nuremberg,undefined
[3] Maximiliansplatz 1,undefined
[4] 91054 Erlangen,undefined
[5] Germany,undefined
[6] Institute of Medical Physics,undefined
[7] Friedrich Alexander University Erlangen–Nuremberg,undefined
[8] Maximiliansplatz 1,undefined
[9] 91054 Erlangen,undefined
[10] Germany,undefined
[11] Siemens AG Medical Solution,undefined
[12] Forchheim,undefined
[13] Germany,undefined
来源
European Radiology | 2002年 / 12卷
关键词
Spiral CT mAs reduction Children Image quality Exposure to patients;
D O I
暂无
中图分类号
学科分类号
摘要
In a controlled patient study we investigated the potential of attenuation-based on-line modulation of the tube current to reduce milliampere values (mAs) in CT examinations of children without loss of image quality. mAs can be reduced for non-circular patient cross sections without an increase in noise if tube current is reduced at those angular positions where the patient diameter and, consequently, attenuation are small. We investigated a technical approach with an attenuation-based on-line control for the tube current realised as a work-in-progress implementation. The CT projection data are analysed in real time to determine optimal mAs values for each projection angle. We evaluated mAs reduction for 100 spiral CT examinations with attenuation-based on-line modulation of the tube current in a group of children. Two radiologists evaluated image quality by visual interpretation in consensus. We compared the mAs values read from the CT scanner with preset mAs of a standard protocol. Four different scan regions were examined in spiral technique (neck, thorax, abdomen, thorax and abdomen). We found the mAs product to be reduced typically by 10–60% depending on patient geometry and anatomical regions. The mean reduction was 22.3% (neck 20%, thorax 23%, abdomen 23%, thorax and abdomen 22%). In general, no deterioration of image quality was observed. There was no correlation between the age and the mean mAs reduction in the different anatomical regions. By classifying the children respectively to their weight, there is a positive trend between increasing weight and mAs reduction. We conclude that mAs in spiral CT examinations of children can be reduced substantially by attenuation-based on-line modulation of the tube current without deterioration of image quality. Attenuation-based on-line modulation of tube current is efficient and practical for reducing dose exposure to children.
引用
收藏
页码:1571 / 1576
页数:5
相关论文
共 50 条
  • [1] Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)
    Greess, H
    Nömayr, A
    Wolf, H
    Baum, U
    Lell, M
    Böwing, B
    Kalender, W
    Bautz, WA
    EUROPEAN RADIOLOGY, 2002, 12 (06) : 1571 - 1576
  • [2] Dose reduction in multidetector CT using attenuation-based online tube current modulation
    Tack, D
    De Maertelaer, V
    Gevenois, PA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) : 331 - 334
  • [3] Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions
    H. Greess
    H. Wolf
    U. Baum
    M. Lell
    M. Pirkl
    W. Kalender
    W. A. Bautz
    European Radiology, 2000, 10 : 391 - 394
  • [4] Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions
    Greess, H
    Wolf, H
    Baum, U
    Lell, M
    Pirkl, M
    Kalender, W
    Bautz, WA
    EUROPEAN RADIOLOGY, 2000, 10 (02) : 391 - 394
  • [5] Attenuation-based Automatic Tube Voltage Selection and Tube Current Modulation for Dose Reduction at Contrast-enhanced Liver CT
    Lee, Kyung Hee
    Lee, Jeong Min
    Moon, Sung Kyoung
    Baek, Jee Hyun
    Park, Ji Hoon
    Flohr, Thomas G.
    Kim, Kyung Won
    Kim, Soo Jin
    Han, Joon Koo
    Choi, Byung Ihn
    RADIOLOGY, 2012, 265 (02) : 437 - 447
  • [6] Dose Reduction Strategy Using Attenuation-Based Tube Current Modulation Method in CBCT for IGRT
    Son, K.
    Lee, H.
    Kim, C.
    Kim, J.
    Cho, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3414 - 3415
  • [7] Optimal dose reduction algorithm using an attenuation-based tube current modulation method for cone-beam CT imaging
    Son, Kihong
    Chang, Jieun
    Lee, Hoyeon
    Kim, Changhwan
    Lee, Taewon
    Cho, Seungryong
    Park, Sohyun
    Kim, Jin Sung
    PLOS ONE, 2018, 13 (02):
  • [8] Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation
    H. Greess
    J. Lutze
    A. Nömayr
    H. Wolf
    T. Hothorn
    W. A. Kalender
    W. Bautz
    European Radiology, 2004, 14 : 995 - 999
  • [9] Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation
    Greess, H
    Lutze, J
    Nömayr, A
    Wolf, H
    Hothorn, T
    Kalender, WA
    Bautz, W
    EUROPEAN RADIOLOGY, 2004, 14 (06) : 995 - 999
  • [10] Angular on-line tube current modulation in multidetector CT examinations of children and adults: The influence of different scanning parameters on dose reduction
    Papadakis, Antonios E.
    Perisinakis, Kostas
    Damilakis, John
    MEDICAL PHYSICS, 2007, 34 (07) : 2864 - 2874