Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)

被引:0
|
作者
Holger Greess
Anton Nömayr
Heiko Wolf
Ulrich Baum
Michael Lell
Bernhard Böwing
Willi Kalender
Werner A. Bautz
机构
[1] Institute of Diagnostic Radiology,
[2] Friedrich Alexander University Erlangen–Nuremberg,undefined
[3] Maximiliansplatz 1,undefined
[4] 91054 Erlangen,undefined
[5] Germany,undefined
[6] Institute of Medical Physics,undefined
[7] Friedrich Alexander University Erlangen–Nuremberg,undefined
[8] Maximiliansplatz 1,undefined
[9] 91054 Erlangen,undefined
[10] Germany,undefined
[11] Siemens AG Medical Solution,undefined
[12] Forchheim,undefined
[13] Germany,undefined
来源
European Radiology | 2002年 / 12卷
关键词
Spiral CT mAs reduction Children Image quality Exposure to patients;
D O I
暂无
中图分类号
学科分类号
摘要
In a controlled patient study we investigated the potential of attenuation-based on-line modulation of the tube current to reduce milliampere values (mAs) in CT examinations of children without loss of image quality. mAs can be reduced for non-circular patient cross sections without an increase in noise if tube current is reduced at those angular positions where the patient diameter and, consequently, attenuation are small. We investigated a technical approach with an attenuation-based on-line control for the tube current realised as a work-in-progress implementation. The CT projection data are analysed in real time to determine optimal mAs values for each projection angle. We evaluated mAs reduction for 100 spiral CT examinations with attenuation-based on-line modulation of the tube current in a group of children. Two radiologists evaluated image quality by visual interpretation in consensus. We compared the mAs values read from the CT scanner with preset mAs of a standard protocol. Four different scan regions were examined in spiral technique (neck, thorax, abdomen, thorax and abdomen). We found the mAs product to be reduced typically by 10–60% depending on patient geometry and anatomical regions. The mean reduction was 22.3% (neck 20%, thorax 23%, abdomen 23%, thorax and abdomen 22%). In general, no deterioration of image quality was observed. There was no correlation between the age and the mean mAs reduction in the different anatomical regions. By classifying the children respectively to their weight, there is a positive trend between increasing weight and mAs reduction. We conclude that mAs in spiral CT examinations of children can be reduced substantially by attenuation-based on-line modulation of the tube current without deterioration of image quality. Attenuation-based on-line modulation of tube current is efficient and practical for reducing dose exposure to children.
引用
收藏
页码:1571 / 1576
页数:5
相关论文
共 50 条
  • [31] A Preliminary Method of Risk-Informed Optimization of Tube Current Modulation for Dose Reduction in CT
    Gao, Y.
    Liu, T.
    Li, X.
    Liu, B.
    Kalra, M.
    Caracappa, P.
    Xu, X.
    MEDICAL PHYSICS, 2015, 42 (06) : 3622 - 3622
  • [32] Dose reduction in subsecond multi-slice spiral CT by online tube current modulation
    Kalender, WA
    Schmidt, B
    Wolf, H
    Suess, C
    Decker, R
    Greess, H
    RADIOLOGY, 2000, 217 : 487 - 487
  • [33] Quantitative Effects of Clinical Practice On the Efficiency of CT Tube Current Modulation for Radiation Dose Reduction
    Zhang, J.
    Cornett, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3635 - 3635
  • [34] Attenuation-Based Dynamic CT Bowtie Filtration: Evaluation of Signal Homogenization and Dose Reduction by Monte-Carlo Simulation
    Veloza, S.
    Kauczor, H. U.
    Stiller, W.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [35] Estimation of breast dose reduction potential for organ-based tube current modulated CT with wide dose reduction arc
    Fu, Wanyi
    Sturgeon, Gregory M.
    Agasthya, Greeshma
    Segars, W. Paul
    Kapadia, Anuj J.
    Samei, Ehsan
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [36] Prospective estimation of organ dose in CT under tube current modulation
    Tian, Xiaoyu
    Li, Xiang
    Segars, W. Paul
    Frush, Donald P.
    Samei, Ehsan
    MEDICAL PHYSICS, 2015, 42 (04) : 1575 - 1585
  • [37] Implementation of Tube Current Modulation into An Organ Dose Calculator for CT Patients
    Lee, C.
    Yeom, Y.
    Atkinson, J.
    Folio, L.
    MEDICAL PHYSICS, 2020, 47 (06) : E264 - E264
  • [38] Influence of CT automatic tube current modulation on uncertainty in effective dose
    Sookpeng, S.
    Martin, C. J.
    Gentle, D. J.
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (01) : 46 - 54
  • [39] Organ-Based Dose Current Modulation and Thyroid Shields: Techniques of Radiation Dose Reduction for Neck CT
    Hoang, Jenny K.
    Yoshizumi, Terry T.
    Choudhury, Kingshuk Roy
    Nguyen, Giao B.
    Toncheva, Greta
    Gafton, Andreia R.
    Eastwood, James D.
    Lowry, Carolyn
    Hurwitz, Lynne M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05) : 1132 - 1138
  • [40] Patient Dose Monitoring in CT with Tube Current Modulation and Multiple Series
    Boone, J.
    Dixon, R.
    Li, B.
    Zhang, D.
    Li, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E374 - E374