Fractal dimension based carotid plaque characterization from three-dimensional ultrasound images

被引:0
|
作者
Ran Zhou
Yongkang Luo
Aaron Fenster
John David Spence
Mingyue Ding
机构
[1] Huazhong University of Science and Technology,Medical Ultrasound Laboratory, Department of Biomedical Engineering, College of Life Science and Technology
[2] Huazhong University of Science and Technology,Key Laboratory of Molecular Biophysics of Education Ministry of China
[3] Western University,Imaging Research Laboratories, Robarts Research Institute
[4] Western University,Stroke Prevention and Atherosclerosis Research Centre, Robarts Research Institute
来源
Medical & Biological Engineering & Computing | 2019年 / 57卷
关键词
Fractal dimension; Carotid plaque characterization; Three-dimensional ultrasound; Vulnerable plaque;
D O I
暂无
中图分类号
学科分类号
摘要
Irregularity of the plaque surface associated with previous plaque rupture plays an important role in the risk estimation of stroke caused by carotid atherosclerotic lesions. Thus, the aim of this study is to develop and validate novel vulnerability biomarkers from three-dimensional ultrasound (3DUS) images by analyzing the surface morphological characteristics of carotid plaque using fractal geometry features. In the experiments, a total of 38 3DUS plaque images were obtained from two groups of patients treated with 80 mg of atorvastatin or placebo daily for 3 months respectively. Two types of 3D fractal dimensions (FDs) were used to describe the smoothness of plaque surface morphology and the roughness from intensity of 3DUS images. Student’s t test showed that the two fractal features were effective for detecting the statin-related changes in carotid atherosclerosis with p < 0.00023 and p < 0.0113 respectively. It was concluded that the 3D FD measurements were effective for analyzing carotid plaque characteristics and especially effective for evaluating the impact of atorvastatin treatment.
引用
收藏
页码:135 / 146
页数:11
相关论文
共 50 条
  • [31] Using three-dimensional fractal dimension to analyze the complexity of fetal cortical surface from magnetic resonance images
    Wu, Yu-Te
    Shyu, Kuo-Kai
    Chen, Tzong-Rong
    Guo, Wan-Yuo
    NONLINEAR DYNAMICS, 2009, 58 (04) : 745 - 752
  • [32] Longitudinal assessment of carotid plaque texture in three-dimensional ultrasound images based on semi-supervised graph-based dimensionality reduction and feature selection
    Lin, Mingquan
    Cui, He
    Chen, Weifu
    van Engelen, Arna
    de Bruijne, Marleen
    Azarpazhooh, M. Reza
    Sohrevardi, Seyed Mojtaba
    Spence, J. David
    Chiu, Bernard
    COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 116
  • [33] Three-Dimensional and Conventional Carotid Ultrasound for Assessment of Carotid Plaque in a Stroke Patient: A Simple Way to Validate Findings
    Kalashyan, Hayrapet
    Saqqur, Maher
    Becher, Harald
    O'Kelly, Cian
    Romanchuk, Helen
    Khan, Khurshid
    Jeerakathil, Thomas
    Wassef, Andrew
    Shuaib, Ashfaq
    CANADIAN JOURNAL OF CARDIOLOGY, 2017, 33 (03) : 412.e1 - 412.e3
  • [34] Accuracy and variability assessment of a semiautomatic technique for segmentation of the carotid arteries from three-dimensional ultrasound images
    Gill, JD
    Ladak, HM
    Steinman, DA
    Fenster, A
    MEDICAL PHYSICS, 2000, 27 (06) : 1333 - 1342
  • [35] Three-Dimensional Reconstruction of Ultrasound Images Based on Area Iteration
    Chen, Biying
    Zhu, Haijiang
    Zhou, Jinglin
    Yang, Ping
    He, Longbiao
    COMPUTER VISION, PT I, 2017, 771 : 218 - 230
  • [36] Computerized characterization of breast masses using three-dimensional ultrasound images
    Sahiner, B
    LeCarpentier, GL
    Chan, HP
    Roubidoux, MA
    Petrick, N
    Goodsitt, MM
    Sanjay-Gopal, S
    Carson, PL
    MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 301 - 312
  • [37] Image segmentation and tissue characterization in three-dimensional intravascular ultrasound images
    Zhang, XM
    DeJong, S
    McKay, C
    Sonka, M
    IMAGE PROCESSING - MEDICAL IMAGING 1997, PTS 1 AND 2, 1997, 3034 : 131 - 137
  • [38] Comparison and Accuracy of Carotid Plaque Analysis Between Two- and Three-Dimensional Ultrasound Imaging
    Kingstone, Lysa Legault
    Shabana, Wael
    Thornhill, Rebecca
    White, Megan
    Lam, Joanna
    Currie, Geoff
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2014, 30 (03) : 123 - 130
  • [39] Three-dimensional registration of prostate images from histology and ultrasound
    Taylor, LS
    Porter, BC
    Nadasdy, G
    Di Sant'Agnese, PA
    Pasternack, D
    Wu, Z
    Baggs, RB
    Rubenst, DJ
    Parker, KJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (02): : 161 - 168
  • [40] Three-dimensional sphericity, roundness and fractal dimension of sand particles
    Zhou, B.
    Wang, J.
    Wang, H.
    GEOTECHNIQUE, 2018, 68 (01): : 18 - 30