Pencil-beam versus fan-beam dual-energy X-ray absorptiometry comparisons across four systems: appendicular lean soft tissue

被引:0
|
作者
E. Ioannidou
J. Padilla
J. Wang
S. B. Heymsfield
J. C. Thornton
M. Horlick
D. Gallagher
R. N. Pierson
机构
[1] New York Obesity Research Center,New York Obesity Research Center St. Luke’s
[2] Columbia University,Roosevelt Hospital, Institute of Human Nutrition College of Physicians and Surgeons
来源
Acta Diabetologica | 2003年 / 40卷
关键词
Body composition; Skeletal muscle mass;
D O I
暂无
中图分类号
学科分类号
摘要
Dual-energy X-ray absorptiometry (DXA) provides an important opportunity for estimating total body skeletal muscle (SM) mass from DXA-measured appendicular lean soft tissue (ALST). A DXA SM prediction model was developed with magnetic resonance imaging as the reference and ALST (i. e., sum of arm plus leg lean soft tissue) as a main predictor variable. In the present study we examined whether ALST estimates are comparable across systems (i. e., penciland fan-beam) and manufacturers. Pencil-beam systems (Lunar DPX and DPX-L) are usually considered more accurate but slower than fan-beam systems (Lunar Prodigy and Hologic Delphi A). In this study we compared ALST estimates in 35 healthy adults across these four systems. The methods gave similar group mean (±SD) values and were highly intercorrelated. There was no significant bias detected across the four systems. ALST estimates from the evaluated DXA systems are comparable and thus appear interchangeable as methods for quantifying total body SM in vivo.
引用
收藏
页码:s83 / s85
相关论文
共 50 条
  • [21] Longitudinal reproducibility for measurement of body composition and bone mineral by a fan-beam dual energy x-ray absorptiometry
    Wang, J
    Thornton, J
    Ioannidou, E
    Gallagher, D
    Horlick, M
    Heymsfield, S
    Pierson, R
    Allen, L
    [J]. OBESITY RESEARCH, 2004, 12 : A227 - A227
  • [22] Assessment of the radiocarpal joint space using fan beam dual-energy X-ray absorptiometry (DXA).
    Norris, JC
    Goh, KL
    Wilkinson, SJ
    Hukins, DWL
    Reid, DM
    [J]. ARTHRITIS AND RHEUMATISM, 1998, 41 (09): : S51 - S51
  • [23] Multichannel FPGA-based Data Acquisition System for Fan-beam Dual Energy X-ray Absorptiometry
    Minh-Duc Hoang
    Kang, Jihoon
    [J]. JOURNAL OF MAGNETICS, 2022, 27 (04) : 498 - 505
  • [24] Effect of thickness and composition of soft tissue and soft tissue equivalent material on spine fan beam dual energy X-ray absorptiometry (DEXA)
    RussellAulet, M
    Marbury, P
    Sowers, MF
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 : S594 - S594
  • [25] Bone mineral density of opposing hips using dual energy X-ray absorptiometry in single-beam and fan-beam design
    Franck, H
    Munz, M
    Scherrer, M
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1997, 61 (06) : 445 - 447
  • [26] Precision error of fan-beam dual X-ray absorptiometry scans at spine, hip, and forearm
    Henzell, S
    Dhaliwal, S
    Pontifex, R
    Gill, F
    Price, R
    Retallack, R
    Prince, R
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2000, 3 (04) : 359 - 364
  • [27] Body composition measurements with fan beam dual energy x-ray absorptiometry
    Koo, W
    Hammami, M
    [J]. PEDIATRIC RESEARCH, 2002, 51 (04) : 314A - 315A
  • [28] Bone Mineral Density of Opposing Hips Using Dual Energy X-Ray Absorptiometry in Single-Beam and Fan-Beam Design
    H. Franck
    M. Munz
    M. Scherrer
    [J]. Calcified Tissue International, 1997, 61 : 445 - 447
  • [29] Comparisons between dual-energy X-ray absorptiometry and bioimpedance devices for appendicular lean mass and muscle quality in Hispanic adults
    Nassar, Bassel
    Tinsley, Grant M.
    Park, Kyung-Shin
    Czerwinski, Stefan A.
    Nickerson, Brett S.
    [J]. BRITISH JOURNAL OF NUTRITION, 2024, 131 (12) : 2005 - 2030
  • [30] Measurements of bone mineral density in the lumbar spine and proximal femur using lunar prodigy and the new pencil-beam dual-energy X-ray absorptiometry
    Reilingh, Mikel L.
    Beimers, Lijkele
    Tuijthof, Gabrielle J. M.
    Stufkens, Sjoerd A. S.
    Maas, Mario
    van Dijk, C. Niek
    [J]. SKELETAL RADIOLOGY, 2010, 39 (11) : 1103 - 1108